My WebLink
|
Help
|
About
|
Sign Out
Home
COM 1024.000 2018-2020
ClerkCouncil
>
Council Records
>
Communications
>
2018-2020
>
COM 1024.000 2018-2020
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/1/2020 4:32:40 PM
Creation date
8/3/2020 8:18:03 AM
Metadata
Fields
Template:
Communications
Communications - Type
COM
Communications - Council Term
2018-2020
Communication
1024
Point
000
Author
Harry Kim, Mayor
Communications - Referred To
PC
Document Relationships
AGE COUNCIL 2020-09-02 2018-2020
(Related)
Path:
\Council Records\Agendas\2018-2020\Council
AGE PC 2020/08/18 (2018-2020)
(Related)
Path:
\Council Records\Agendas\2018-2020\Planning Committee (PC)
BIL 183 Draft 01 2018-2020
(Related To)
Path:
\Council Records\Bills\2018-2020
REP PC 053 2020/08/18 2018-2020
(Related To)
Path:
\Council Records\Reports\2018-2020\Planning Committee (PC)
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
83
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
calculations as recommended by a registered engineer, and a daily water <br />commitment deposit in accordance with the "Water Commitment Guidelines <br />Policy" to the Department of Water Supply within one hundred and eighty <br />(180) days from the effective date of this ordinance. <br />This has already been addressed and accommodated, enabling the issuance of <br />the initial building permit for the project. <br />C. The applicant shall install a reduced pressure type of backflow prevention <br />assembly within five (5) feet of the water meter on private property, which <br />must be inspected and approved by the Department of Water Supply. <br />This is reflected in the construction plans for the pending building permit. <br />This will be completed prior to the issuance of an occupancy permit for the <br />building. <br />D. Construction of the proposed improvements shall be completed within five (5) <br />years from the effective date of this ordinance. This time period shall include <br />securing Final Plan Approval from the Planning Director.... Plans shall <br />identify structures, fire protection measures, paved access and loading zones. <br />Landscaping shall be indicated on the plans for the purpose of mitigating any <br />potential adverse noise and visual impacts to adjoining parcels. Landscaping <br />shall be provided in accordance with the requirements of Planning <br />Department's Rule No. 17 (Landscaping Requirements). <br />As noted above, Final Plan Approval was issued on June 8, 2011 (Exhibit B) <br />and the corresponding building permit issued on November 7, 2011 (Exhibit <br />Q. However, while only limited site work was done, construction of the <br />structure has not commenced. As such, the Applicant is requesting a 5 -year <br />time extension from the effective date of the amendment to complete the <br />structure. <br />E. Development of the property shall be designed and constructed in away to <br />minimize obstruction of the scenic views ofHilo Bay and the Puna shoreline <br />from Komohana Street. <br />This has been addressed in conjunction with the review and ultimate approval <br />of the plans via the Plan Approval process. <br />F. Prior to the issuance of a Certificate of Occupancy, the applicant shall <br />provide full improvements to the property's frontage along Komohana Street <br />consisting of, but not limited to, pavement widening with curb, gutter and <br />sidewalk, drainage improvements, and any required utility relocation, meeting <br />with the approval of the Department of Public Works. <br />3 <br />
The URL can be used to link to this page
Your browser does not support the video tag.