Laserfiche WebLink
"TABLE R301.2.1.2 <br /> WINDBOURNE DEBRIS PROTECTION FASTENING <br /> SCHEDULE FOR WOOD STRUCTURAL PANELS a,b,c,d <br /> Fastener Snacina <br /> Fastener Type Panel span 4 feet < Panel 6 feet < Panel <br /> < 4 feet span < 6 feet Span <br /> < 8 feet <br /> No. 8 Wood screw based 16" IUI 8" <br /> anchor with 2-inch embedment <br /> length <br /> No. 10 Wood screw based 161, 12" 91, <br /> anchorwith2-inch embedment <br /> leng,th <br /> 1/4-inch lag screw based 16" 16" 16" <br /> anchor with 2-inch embedment <br /> length <br /> For SI: 1.inch=25.4 mm, I-foot--,304.8 mm, I pound=4.448N=0A54 kg_I mile per hour--0.447 m/s= 1.609 knw/h. <br /> a. 'Phis table is based on a 175 mph ultimate design wind speed and a mean roof height of 45 feet. <br /> b. Fasteners shall be installed at opposing ends of the wood structural pan.eL.Pasteners shall be located a <br /> minimum of I inch from the edge of the panel. <br /> C. Anchors shall penetrate through the exterior wall covering with an embedment length-of 2 inches <br /> minimum into the building frame.Fasteners shall be located a minimum of 2-1/2 inches from the edge o <br /> concrete block or concrete. <br /> d. Where panels are attached to masonry or ma&D)�nr /stucco they shall be attacbed utilizingviibrabon- <br /> - <br /> resistant anchors having a minimum withdrawal capacity of 1,500 pounds." <br /> (13) Figure R301.2(5)(a) "Ultimate Design Wind Speeds" of the International <br /> Residential Code is deleted in its entirety and replaced with Figure R301.2(5)(a) <br /> County of Hawaii Ultimate Wind Speed, VULT, for Components and Cladding, to <br /> read as follows: (Although not underscored, figure is intended to be added.) <br /> 12 <br />