My WebLink
|
Help
|
About
|
Sign Out
Home
BIL 044 Draft 02 2020-2022
ClerkCouncil
>
Council Records
>
Bills
>
2020-2022
>
BIL 044 Draft 02 2020-2022
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/31/2021 3:25:33 PM
Creation date
8/10/2021 8:40:07 AM
Metadata
Fields
Template:
Bill/Resolution
Bill/Resolution - Type
BIL
Bill/Resolution - Council Term
2020-2022
Bill/Resolution
044
Draft
02
Introducer
Susan L. K. Lee Loy, Council Member
Referred To
COUNCIL
Action 1
Council: Bill 44 Draft 2, passes first reading - 8/4/21
Action 2
Council: Bill 44 Draft 2, passes second & final reading - 8/18/21
Date To Mayor or Adoption Date
8/27/2021
Reading Number
1
Reading Date
8/4/2021
Ayes
7-Chung, David, Inaba, Kierkiewicz, Kimball, Lee Loy, Richards
Noes
1-Villegas
Absent
1-Kaneali'i-Kleinfelder
Excused
0
Reading Number .
2
Reading Date .
8/18/2021
Ayes .
5-David, Inaba, Kierkiewicz, Kimball, Lee Loy
Noes .
2-Kaneali'i-Kleinfelder, Villegas
Absent .
2-Chung, Richards
Excused .
0
Document Relationships
AGE COUNCIL 2021-08-18 2020-2022
(Related To)
Path:
\Council Records\Agendas\2020-2022\Council
COM 0281.032 2020-2022
(Related)
Path:
\Council Records\Communications\2020-2022
ORD 2021-061 2020-2022
(Related To)
Path:
\Council Records\Ordinances\2021
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
78
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
"TABLE R301.2.1.2 <br /> WINDBOURNE DEBRIS PROTECTION FASTENING <br /> SCHEDULE FOR WOOD STRUCTURAL PANELS a,b,c,d <br /> Fastener Spacing <br /> Fastener Type Panel span 4 feet < Panel 6 feet < Panel <br /> <4 feet span < 6 feet Span <br /> <8 feet <br /> No. 8 Wood screw based 16" 10" 8" <br /> anchor with 2-inch embedment <br /> length <br /> No. 10 Wood screw based 16" 12" 9" <br /> anchor with 2-inch embedment <br /> length <br /> 1/4-inch lag screw based 16" 16" 16" <br /> anchor with 2-inch embedment <br /> length <br /> For SI: 1 inch=25.4 mm, 1 foot=304.8 mm, 1 pound=4.448N=0.454 kg, 1 mile per hour=0.447 m/s=1.609 km/h. <br /> a. This table is based on a 175 mph ultimate design wind speed and a mean roof height of 45 feet. <br /> b. Fasteners shall be installed at opposing ends of the wood structural panel.Fasteners shall be located a <br /> minimum of 1 inch from the edge of the panel. <br /> c. Anchors shall penetrate through the exterior wall covering with an embedment length of 2 inches <br /> minimum into the building frame.Fasteners shall be located a minimum of 2-1/2 inches from theedge of <br /> concrete block or concrete. <br /> d. Where panels are attached to masonry or masonry/stucco,they shall be attached utilizing vibration- <br /> resistant anchors having a minimum withdrawal capacity of 1,500 pounds." <br /> (13) Figure R301.2(5)(a) "Ultimate Design Wind Speeds" of the International <br /> Residential Code is deleted in its entirety and replaced with Figure R301.2(5)(a) <br /> County of Hawai`i Ultimate Wind Speed, VULT, for Components and Cladding, to <br /> read as follows: (Although not underscored, figure is intended to be added.) <br /> 12 <br />
The URL can be used to link to this page
Your browser does not support the video tag.