My WebLink
|
Help
|
About
|
Sign Out
Home
BIL 044 Draft 02 2020-2022
ClerkCouncil
>
Council Records
>
Bills
>
2020-2022
>
BIL 044 Draft 02 2020-2022
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/31/2021 3:25:33 PM
Creation date
8/10/2021 8:40:07 AM
Metadata
Fields
Template:
Bill/Resolution
Bill/Resolution - Type
BIL
Bill/Resolution - Council Term
2020-2022
Bill/Resolution
044
Draft
02
Introducer
Susan L. K. Lee Loy, Council Member
Referred To
COUNCIL
Action 1
Council: Bill 44 Draft 2, passes first reading - 8/4/21
Action 2
Council: Bill 44 Draft 2, passes second & final reading - 8/18/21
Date To Mayor or Adoption Date
8/27/2021
Reading Number
1
Reading Date
8/4/2021
Ayes
7-Chung, David, Inaba, Kierkiewicz, Kimball, Lee Loy, Richards
Noes
1-Villegas
Absent
1-Kaneali'i-Kleinfelder
Excused
0
Reading Number .
2
Reading Date .
8/18/2021
Ayes .
5-David, Inaba, Kierkiewicz, Kimball, Lee Loy
Noes .
2-Kaneali'i-Kleinfelder, Villegas
Absent .
2-Chung, Richards
Excused .
0
Document Relationships
AGE COUNCIL 2021-08-18 2020-2022
(Related To)
Path:
\Council Records\Agendas\2020-2022\Council
COM 0281.032 2020-2022
(Related)
Path:
\Council Records\Communications\2020-2022
ORD 2021-061 2020-2022
(Related To)
Path:
\Council Records\Ordinances\2021
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
78
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Exception: Portions of floors that do not support shear walls, braced wall <br /> panels above, or roofs shall be permitted to extend not more than 6 feet <br /> (1829 mm) beyond a shear wall or braced wall line. See Figure <br /> R301.2.2.6(4). <br /> ROOF OR FLOOR SHALL BE PERMITTED <br /> TO EXTEND UP TO 6'BEYOND <br /> { THE BRACED WALL LINE <br /> La <br /> PLAN VIEW NO BRACED WALL PANEL ABOVE <br /> PERMITTED AT THIS LOCATION <br /> Figure R301.2.2.6(4) <br /> Roof or Floor Extension Beyond Braced Wall Line <br /> 3. Shear wall or braced wall offsets in plane. Conditions where the end of <br /> a braced wall panel occurs over an opening in the wall below and extends <br /> more than 1 foot (305 mm) horizontally past the edge of the opening. This <br /> provision is applicable to shear walls and braced wall panels offset in plane <br /> and to braced wall panels offset out of plane in accordance with the <br /> exception to Item 1. See Figure R301.2.2.6(5). <br /> �� `•`'�•,_ REQUIRED BRACED ,j •,•,� <br /> WALL PANEL <br /> 'i— <br /> -iI <br /> I 1 I '' <br /> } MORE THAN 7'•0" ' <br /> ir <br /> EXTERIOR ELEVATION EXTERIOR ISOMETRIC <br /> Figure R301.2.2.6(5) <br /> Braced Wall Panel Extension Over Opening <br /> Exception: For wood light-frame wall construction, one end of a braced <br /> wall panel shall be permitted to extend more than 1 foot (305 mm) over an <br /> opening not more than 8 feet (2438 mm) in width in the wall below provided <br /> that the opening includes a header in accordance with all of the following: <br /> 1. The building width, loading condition and framing member species <br /> limitations of Table R602.7(1) shall apply. <br /> 2. The header is composed of: <br /> 2.1. Not less than one 2 x 12 or two 2 x 10 for an opening not more <br /> than 4 feet (1219 mm)wide. <br /> 2.2. Not less than two 2 x 12 or three 2 x 10 for an opening not more <br /> than 6 feet (1829 mm) in width. <br /> 20 <br />
The URL can be used to link to this page
Your browser does not support the video tag.