My WebLink
|
Help
|
About
|
Sign Out
Home
BIL 044 Draft 02 2020-2022
ClerkCouncil
>
Council Records
>
Bills
>
2020-2022
>
BIL 044 Draft 02 2020-2022
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/31/2021 3:25:33 PM
Creation date
8/10/2021 8:40:07 AM
Metadata
Fields
Template:
Bill/Resolution
Bill/Resolution - Type
BIL
Bill/Resolution - Council Term
2020-2022
Bill/Resolution
044
Draft
02
Introducer
Susan L. K. Lee Loy, Council Member
Referred To
COUNCIL
Action 1
Council: Bill 44 Draft 2, passes first reading - 8/4/21
Action 2
Council: Bill 44 Draft 2, passes second & final reading - 8/18/21
Date To Mayor or Adoption Date
8/27/2021
Reading Number
1
Reading Date
8/4/2021
Ayes
7-Chung, David, Inaba, Kierkiewicz, Kimball, Lee Loy, Richards
Noes
1-Villegas
Absent
1-Kaneali'i-Kleinfelder
Excused
0
Reading Number .
2
Reading Date .
8/18/2021
Ayes .
5-David, Inaba, Kierkiewicz, Kimball, Lee Loy
Noes .
2-Kaneali'i-Kleinfelder, Villegas
Absent .
2-Chung, Richards
Excused .
0
Document Relationships
AGE COUNCIL 2021-08-18 2020-2022
(Related To)
Path:
\Council Records\Agendas\2020-2022\Council
COM 0281.032 2020-2022
(Related)
Path:
\Council Records\Communications\2020-2022
ORD 2021-061 2020-2022
(Related To)
Path:
\Council Records\Ordinances\2021
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
78
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
3. Use of sunroom and patio covers, as defined in Section R202, shall be <br /> permitted for natural ventilation if in excess of[48] 65 percent of the exterior <br /> sunroom walls are open, or are enclosed only by insect screening." <br /> (24) Subsection R303.3, "Bathrooms," of the International Residential Code is <br /> amended to read as follows: <br /> "R303.3 Bathrooms. Bathrooms, water closet compartments, laundry rooms, <br /> and other similar rooms shall be provided with [aggregate glazing area in <br /> windows of not less than 3 square feet (0.3 ma), one half of which must be <br /> fie] natural ventilation by means of openable exterior openings with an <br /> area not less than one twentieth of the floor area of such rooms with a minimum <br /> of 1 1/2 square feet." <br /> Exception: The glazed areas shall not be required where artificial light and a <br /> local exhaust system are provided. The minimum local exhaust rates shall be <br /> determined in accordance with Section M1505. Exhaust air from the space shall <br /> be exhausted directly to the outdoors." <br /> (25) Subsection R309.3, "Flood hazard areas," of the International Residential Code is <br /> amended to read as follows: <br /> "R309.3 Flood hazard areas. [- . . .' .•-_ . . . . •- y... • . . . . .. .. <br /> established by Table R301.2(1), garage floors shall be one of the following: <br /> 1. Elevated to or above the design flood elevation as determined in accordance <br /> with Section R322. <br /> 2. Located below the design flood elevation provided that the floors arc at or <br /> constructed in accordance with this code.] Buildings located within areas of <br /> special flood hazards pursuant to Chapter 27, Hawai`i County Code, shall be <br /> designed and constructed in accordance with Chapter 27, Hawai`i County <br /> Code." <br /> (26) Subsection R310.2.1, "Minimum opening area," of the International Residential <br /> Code is amended to read as follows: <br /> "R310.2.1 Minimum opening area. Emergency and escape rescue openings <br /> shall have a net clear opening of not less 5.7 square feet (0.530 m2). The net clear <br /> opening dimensions required by this section shall be obtained by the normal <br /> operation of the emergency escape and rescue opening from the inside. The net <br /> clear height of the opening shall be not less than 24 inches (610 mm) and the net <br /> clear width shall be not less than 20 inches (508 mm). <br /> [E-xeeptien] Exceptions: <br /> 1. Grade floor openings or below-grade openings shall have a net clear opening <br /> area of not less than 5 square feet (0.465 m2). <br /> 2. Glass jalousie bladed windows may be used for emergency escape or rescue." <br /> 23 <br />