My WebLink
|
Help
|
About
|
Sign Out
Home
BIL 044 Draft 02 2020-2022
ClerkCouncil
>
Council Records
>
Bills
>
2020-2022
>
BIL 044 Draft 02 2020-2022
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/31/2021 3:25:33 PM
Creation date
8/10/2021 8:40:07 AM
Metadata
Fields
Template:
Bill/Resolution
Bill/Resolution - Type
BIL
Bill/Resolution - Council Term
2020-2022
Bill/Resolution
044
Draft
02
Introducer
Susan L. K. Lee Loy, Council Member
Referred To
COUNCIL
Action 1
Council: Bill 44 Draft 2, passes first reading - 8/4/21
Action 2
Council: Bill 44 Draft 2, passes second & final reading - 8/18/21
Date To Mayor or Adoption Date
8/27/2021
Reading Number
1
Reading Date
8/4/2021
Ayes
7-Chung, David, Inaba, Kierkiewicz, Kimball, Lee Loy, Richards
Noes
1-Villegas
Absent
1-Kaneali'i-Kleinfelder
Excused
0
Reading Number .
2
Reading Date .
8/18/2021
Ayes .
5-David, Inaba, Kierkiewicz, Kimball, Lee Loy
Noes .
2-Kaneali'i-Kleinfelder, Villegas
Absent .
2-Chung, Richards
Excused .
0
Document Relationships
AGE COUNCIL 2021-08-18 2020-2022
(Related To)
Path:
\Council Records\Agendas\2020-2022\Council
COM 0281.032 2020-2022
(Related)
Path:
\Council Records\Communications\2020-2022
ORD 2021-061 2020-2022
(Related To)
Path:
\Council Records\Ordinances\2021
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
78
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
R323.6 Design for dead, live, wind, rain, and impact loads. <br /> R323.6.1 Structural integrity criteria. <br /> 1. The residential safe room shall be built with a complete <br /> structural system and a complete load path for vertical and <br /> lateral loads caused by gravity and wind. <br /> 2. The building that the residential safe room is in shall be assumed <br /> to be destroyed by the storm and shall not be taken as offering <br /> any protective shielding to the safe room enclosure. <br /> 3. The ceiling structure and wall shall be capable of supporting a <br /> superimposed debris load of the full weight of any building floors <br /> and roof above, but not less than 125 psf. <br /> 4. The residential safe room enclosure shall be capable of <br /> simultaneously resisting lateral and uplift wind pressures <br /> corresponding to a 145 mph 3-second peak gust ultimate design <br /> wind speed, determined in accordance with ASCE — 7, Minimum <br /> Design Loads for Buildings and Other Structures. The site <br /> exposure factor shall be based on exposure C or the exposure <br /> shown in Figure R301.2.1.4(a), whichever is the greater. The <br /> values for the gust factor and the directionality factor shall be <br /> taken as 0.85. Topographic wind amplification caused by <br /> mountainous terrain shall be considered in accordance with the <br /> building code. Internal pressure shall be determined in <br /> accordance with ASCE— 7. <br /> 5. The residential safe room shall be anchored to a foundation <br /> system capable of resisting the above loading conditions. <br /> R323.6.2 Windborne debris impact protection of building <br /> enclosure elements. The entire enclosure of the safe room, including <br /> all walls, ceilings, and openings, fixed or operable windows, and all <br /> entry doors into the safe room, shall meet or exceed Level D <br /> requirements of ASTM E 1996 (Table 323.6.1), or be an approved <br /> assembly listed in Section 323.6.4. Any wall or ceiling penetration <br /> greater than 4 square inches shall be considered an opening. <br /> Exception: Electrical outlet boxes and interior lighting switches not <br /> penetrating more than 2.5-inches into the interior wall surface and a <br /> plumbing piping or conduit not greater than 1.5-inch in diameter shall <br /> be exempted from this requirement. <br /> p q <br /> R323.6.3 Cyclic pressure loading of glazing and protective <br /> systems. Impact protective systems shall meet the ASTM E 1996 <br /> cyclic pressure requirement for the loading given in Table 323.6.1. <br /> 28 <br />