My WebLink
|
Help
|
About
|
Sign Out
Home
BIL 044 Draft 02 2020-2022
ClerkCouncil
>
Council Records
>
Bills
>
2020-2022
>
BIL 044 Draft 02 2020-2022
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/31/2021 3:25:33 PM
Creation date
8/10/2021 8:40:07 AM
Metadata
Fields
Template:
Bill/Resolution
Bill/Resolution - Type
BIL
Bill/Resolution - Council Term
2020-2022
Bill/Resolution
044
Draft
02
Introducer
Susan L. K. Lee Loy, Council Member
Referred To
COUNCIL
Action 1
Council: Bill 44 Draft 2, passes first reading - 8/4/21
Action 2
Council: Bill 44 Draft 2, passes second & final reading - 8/18/21
Date To Mayor or Adoption Date
8/27/2021
Reading Number
1
Reading Date
8/4/2021
Ayes
7-Chung, David, Inaba, Kierkiewicz, Kimball, Lee Loy, Richards
Noes
1-Villegas
Absent
1-Kaneali'i-Kleinfelder
Excused
0
Reading Number .
2
Reading Date .
8/18/2021
Ayes .
5-David, Inaba, Kierkiewicz, Kimball, Lee Loy
Noes .
2-Kaneali'i-Kleinfelder, Villegas
Absent .
2-Chung, Richards
Excused .
0
Document Relationships
AGE COUNCIL 2021-08-18 2020-2022
(Related To)
Path:
\Council Records\Agendas\2020-2022\Council
COM 0281.032 2020-2022
(Related)
Path:
\Council Records\Communications\2020-2022
ORD 2021-061 2020-2022
(Related To)
Path:
\Council Records\Ordinances\2021
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
78
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
13. Concrete masonry units with a thickness of 6 inches with partial <br /> grouting and reinforcing spaced at 24 inches on-center. <br /> 14. Concrete masonry units with a thickness of 8 inches with partial <br /> grouting and reinforcing spaced at 24 inches on-center. <br /> 15. Interior or exterior wall with laterally braced 2 inch x 4 inch wood <br /> studs with sheathing on either side of 22 gage sheet metal. <br /> Sheathing shall be attached to studs with fasteners at 6 inches (152 <br /> mm) on center for edge and field fastening. <br /> R323.7 Ventilation. The residential safe room shall be naturally <br /> ventilated to allow the enclosure to have approximately one air change <br /> every two hours. This requirement may be satisfied by 12 square <br /> inches of venting per occupant. There shall be at least two operable <br /> vents. The vents shall be protected by a cowling or other device that <br /> shall be impact tested to comply with ASTM E 1996-14 Level D. <br /> Alternatively, the room shall be evaluated to determine if the openings <br /> are of sufficient area to constitute an open or partially enclosed <br /> condition as defined in ASCE 7. <br /> R323.8 Communications. The residential safe room shall be <br /> equipped with a phone line and telephone that does not rely on a <br /> separate electrical power outlet. Alternatively, a wireless telephone <br /> shall be permitted to rely on an Uninterruptible Power Supply(UPS) <br /> battery device. <br /> R323.9 Construction documents. Construction documents for the <br /> residential safe room shall be directly prepared by a Hawaii licensed <br /> professional structural engineer. <br /> R323.10 Special inspection. The construction or installation of the <br /> residential safe room shall be verified for conformance to the drawings <br /> in accordance with the appropriate requirements of Chapter 17 of the <br /> International Building Code. <br /> R323.11 Notification. The owner of the safe room shall notify the <br /> State Department of Defense and County Civil Defense Agency of the <br /> property's Tax Map Key or Global Positioning System coordinates." <br /> (36) Section R326, "Swimming Pools, Spas and Hot Tubs" of the International <br /> Residential Code, is amended to read as follows: <br /> "R326.1 General. [The design and construction of pools and spas shall <br /> comply with the International Swimming Pool and Spa Code.] <br /> Swimming pools shall comply with the requirements of sections R326.2 <br /> through R326.4 and other applicable sections of this code. <br /> 30 <br />
The URL can be used to link to this page
Your browser does not support the video tag.