My WebLink
|
Help
|
About
|
Sign Out
Home
ORD 2021-061 2020-2022
ClerkCouncil
>
Council Records
>
Ordinances
>
2021
>
ORD 2021-061 2020-2022
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/21/2021 2:43:31 PM
Creation date
9/8/2021 2:30:56 PM
Metadata
Fields
Template:
Ordinances
Ordinances - Type
ORD
Ordinances - Council Term
2020-2022
Year
2021
Ordinance
061
Effective Date
9/8/2021
Document Relationships
BIL 044 Draft 02 2020-2022
(Related)
Path:
\Council Records\Bills\2020-2022
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
79
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
remaining structural system. Where the forces associated with the irregularity <br /> are resisted by a structural system designed in accordance with [accepted <br /> engineering practice] the Building Code, Chapter 5A, Hawai`i County Code, the <br /> remainder of the building shall be permitted to be designed using the provisions <br /> of this code. <br /> 1. Shear wall or braced wall offsets out of plane. Conditions where <br /> exterior shear wall lines or braced wall panels are not in one plane <br /> vertically from the foundation to the uppermost story in which they are <br /> required see Figure R301.2.2.6(1). <br /> 3 E----- -------OUT OF PLANE <br /> OFFSET IN EXTERIOR <br /> BRACED WALL PANELS <br /> • <br /> SECTION VIEW SECTION VIEW <br /> Figure R301.2.2.6(1) <br /> Braced Wall Panels Out of Plane <br /> Exception: For wood light-frame construction, floors with cantilevers or <br /> setbacks not exceeding four times the nominal depth of the wood floor <br /> joists, see Figure R301.2.2.6(2), are permitted to support braced wall <br /> panels that are out of plane with braced wall panels below provided that all <br /> of the following are satisfied: <br /> 1. Floor joists are nominal 2 inches by 10 inches (51 mm by 254 mm) or <br /> larger and spaced not more than 16 inches (406 mm) on center. <br /> 2. The ratio of the back span to the cantilever is not less than 2 to 1. <br /> 3. Floor joists at ends of braced wall panels are doubled. <br /> 4. For wood-frame construction, a continuous rim joist is connected to <br /> ends of cantilever joists. Wherespliced, the rim joists shall be spliced <br /> using a galvanized metal tie not less than 0.058 inch (1.5 mm) (16 <br /> gage) and 1-1/2 inches (38 mm)wide fastened with six 16d nails on <br /> each side of the splice; or a block of the same size as the rim joist and <br /> of sufficient length to fit securely between the joist space at which the <br /> splice occurs, fastened with eight 16d nails on each side of the splice. <br /> 18 <br />
The URL can be used to link to this page
Your browser does not support the video tag.