My WebLink
|
Help
|
About
|
Sign Out
Home
ORD 2021-061 2020-2022
ClerkCouncil
>
Council Records
>
Ordinances
>
2021
>
ORD 2021-061 2020-2022
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/21/2021 2:43:31 PM
Creation date
9/8/2021 2:30:56 PM
Metadata
Fields
Template:
Ordinances
Ordinances - Type
ORD
Ordinances - Council Term
2020-2022
Year
2021
Ordinance
061
Effective Date
9/8/2021
Document Relationships
BIL 044 Draft 02 2020-2022
(Related)
Path:
\Council Records\Bills\2020-2022
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
79
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
13. Concrete masonry units with a thickness of 6 inches with partial <br /> grouting and reinforcing spaced at 24 inches on-center. <br /> 14. Concrete masonry units with a thickness of 8 inches with partial <br /> grouting and reinforcing spaced at 24 inches on-center. <br /> 15. Interior or exterior wall with laterally braced 2 inch x 4 inch wood <br /> studs with sheathing on either side of 22 gage sheet metal. <br /> Sheathing shall be attached to studs with fasteners at 6 inches (152 <br /> mm) on center for edge and field fastening. <br /> R323.7 Ventilation. The residential safe room shall be naturally <br /> ventilated to allow the enclosure to have approximately one air change <br /> every two hours. This requirement may be satisfied by 12 square <br /> inches of venting per occupant. There shall be at least two operable <br /> vents. The vents shall be protected by a cowling or other device that <br /> shall be impact tested to comply with ASTM E 1996-14 Level D. <br /> Alternatively, the room shall be evaluated to determine if the openings <br /> are of sufficient area to constitute an open or partially enclosed <br /> condition as defined in ASCE 7. <br /> R323.8 Communications. The residential safe room shall be <br /> equipped with a phone line and telephone that does not rely on a <br /> separate electrical power outlet. Alternatively, a wireless telephone <br /> shall be permitted to rely on an Uninterruptible Power Supply(UPS) <br /> battery device. <br /> R323.9 Construction documents. Construction documents for the <br /> residential safe room shall be directly prepared by a Hawaii licensed <br /> professional structural engineer. <br /> R323.10 Special inspection. The construction or installation of the <br /> residential safe room shall be verified for conformance to the drawings <br /> in accordance with the appropriate requirements of Chapter 17 of the <br /> International Building Code. <br /> R323.11 Notification. The owner of the safe room shall notify the <br /> State Department of Defense and County Civil Defense Agency of the <br /> property's Tax Map Key or Global Positioning System coordinates." <br /> (36) Section R326, "Swimming Pools, Spas and Hot Tubs" of the International <br /> Residential Code, is amended to read as follows: <br /> "R326.1 General. [The design and construction of pools and spas shall <br /> - -- •: ional Swimming Pool and Spa Code.] <br /> Swimming pools shall comply with the requirements of sections R326.2 <br /> through R326.4 and other applicable sections of this code. <br /> 30 <br />
The URL can be used to link to this page
Your browser does not support the video tag.