My WebLink
|
Help
|
About
|
Sign Out
Home
RES 441 Draft 01 2022-2024
ClerkCouncil
>
Council Records
>
Resolutions
>
2022-2024
>
RES 441 Draft 01 2022-2024
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/15/2024 2:14:22 PM
Creation date
2/9/2024 8:42:19 AM
Metadata
Fields
Template:
Bill/Resolution
Bill/Resolution - Type
RES
Bill/Resolution - Council Term
2022-2024
Bill/Resolution
441
Draft
01
Introducer
Cindy Evans, Council Member
Referred To
GOEAC
Action 1
Council: Res. 441-24 amended to Draft 2 - 03/06/24
Document Relationships
AGE COUNCIL 2024-03-06 2022-2024
(Related To)
Path:
\Council Records\Agendas\2022-2024\Council
AGE GOEAC 2024/02/20 (2022-2024)
(Related)
Path:
\Council Records\Agendas\2022-2024\Governmental Operations and External Affairs Committee (GOEAC)
COM 0732.000 2022-2024
(Related)
Path:
\Council Records\Communications\2022-2024
REP GOEAC 111 2024/02/20 (2022-2024)
(Related)
Path:
\Council Records\Reports\2022-2024\Governmental Operations and External Affairs Committee (GOEAC)
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
28
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
lines.The COH shall propose to EPA and DOH the inspection schedule <br /> and frequency for force main inspections and cleaning, where <br /> appropriate,within 6-months of after the initial assessment. <br /> iii. Corrective Actions:A schedule to complete repairs of sewer line <br /> deficiencies identified as being at NASSCO Level 5 (or equivalent) within 36 <br /> months, and deficiencies identified as NASSCO Level 4(or equivalent) <br /> within 5 years. Repairs for sewer lines shall be in accordance with Water <br /> Environment Federation (WEF)guidance to prevent spills due to improper <br /> pipe bedding, line loads, earth movement, root growth damage, openings <br /> in sewer lines, and faulty building sewer connections.The identification <br /> and correction over time of any other sewer line system deficiencies, such <br /> as misaligned pipes, grade deviations, solids build-up, hydrogen sulfide gas <br /> generation, pipe deformation hydraulic overloads, misaligned or damaged <br /> manhole covers, and manholes shall be in accordance with WEF guidance. <br /> Sewer line system deficiencies may, in some cases, be addressed with <br /> increased maintenance. <br /> iv. Controls:The plan shall provide for appropriate control system and <br /> equipment redundancy for each county operated pump station and shall <br /> also provide for timely response to pump station alarms.The plan shall <br /> include a written checklist of standard procedures for pump station <br /> repair and maintenance work for use by County personnel.The plan shall <br /> be based on the County's experience and shall address, where <br /> appropriate, any additional failure scenarios besides operator error. <br /> In re County of Hamill, Docket No. CWA-309(a)-24-003:Appendix 1 Page 9 of 9 <br />
The URL can be used to link to this page
Your browser does not support the video tag.