My WebLink
|
Help
|
About
|
Sign Out
Home
COM 0011.000 2000-2002
ClerkCouncil
>
Council Records
>
Communications
>
2000-2002
>
COM 0011.000 2000-2002
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/12/2008 11:11:16 AM
Creation date
5/10/2008 2:14:48 PM
Metadata
Fields
Template:
Communications
Communications - Type
COM
Communications - Council Term
2000-2002
Communication
0011
Point
000
Author
Thomas E. Arizumi, P.E. Chief, Environmental Management Division State Department of Health
Communications - Referred To
PEMC
Comments
P&EMC: Close file - 12/19/00
Communications - File Code
SEW
Document Relationships
AGE COUNCIL 12/20/2000 2000-2002
(Related)
Path:
\Council Records\Agendas\2000-2002\Council
AGE PEMC 12/19/2000 2000-2002
(Related)
Path:
\Council Records\Agendas\2000-2002\Parks & Envrionmental Management Committee (PEMC)
COM 0032.000 2000-2002
(Related)
Path:
\Council Records\Communications\2000-2002
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
7
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Permit hmtts are as follows <br /> PARAMETER DISCHARGE LIMITATION <br /> BODS 30 mg~l (30-day average) <br /> 45 mg/I (7-day average) <br /> 85 removal) <br /> Total Suspended Solids 30 mgil (30-day average) <br /> 45 mg/I (7-day average) <br /> 85 removal) <br /> pH Range 6 0 - 9 0 Standard Units <br /> Total Residual Chlonne 7 5 ug/I <br /> Enterococc~ 7!100 ml <br /> No v~olanons of the effluent pemut hmitahons were noted <br /> <br /> The COH submitted the facility's NPDES regmred annual reports for operations and sludge <br /> management for the 1999 calendar year <br /> There were no spills or bypasses reported by the fac~lrty dunng the past year The fac~lrty also <br /> received no odor complaints m the past year <br /> MODIFICATIONS/ADDITIONS <br /> Dunng the previous year, a manual transfer s~a•ttch and connectors to provide for the connection <br /> of a portable emergency generator was installed at the fac~l~ry Also, the fac~l~ty's Chlonne alarm <br /> was replaced with a new electronic unit with an external siren <br /> OBSERVATIONS <br /> Influent flow is measured by a Gpolleth weir and ultrasonic level sensor which is calibrated <br /> semiannually by COH mechanics The most recent calibration was performed on July 27, 2000 <br /> Influent flow samples are Flow-proportional composites taken with an automatic sampler The <br /> sampler nozzle was located near the tank wall where grease/scum was accumulating <br /> A V-notch weir and ultrasonic level sensor (m sl~lhng well) measures the effluent flow The <br /> access cover for the st~lhng well ~s bolted down and therefore the ms~de of the sUlhng well ~s not <br /> inspected by the operators It w•as recommended that the operators tnspecvclean the stilling well <br /> at the lime the mechanics perform the semiannual cal~brat~on Effluent samples are also flow- <br /> <br />
The URL can be used to link to this page
Your browser does not support the video tag.