Laserfiche WebLink
MAY 19 '97 a5~3aPM ISOMEDIX CORPORATE P.4i6 , <br /> It should be noted that the same irradiator design was <br /> associated with the Norway, El Salvador and Israel events. <br /> After ttie Norway event, the irradiator manufacturer issued <br /> an information notice along .with a design modification to <br /> prevent a reoccurrence of the cause of the source rack jam. <br /> The notice was apparently ignored by both the other <br /> facilities. <br /> There are .no documented fatalities associated with <br /> industrial irradiators in the United States. <br /> An interlock system designed to meet today's requirements <br /> does not allow far any type of entry with the source in the <br /> exposed position. <br /> 4. How long w.il1 it take for cobalt 60 to turn nonradioactive? <br /> It depends on the. original level of activity but can be <br /> approximated to be around 1~5 years. <br /> 5. Is there a guarantee from the manufacturer that the <br /> cobalt 6o pencils will not Zeak? <br /> Yes; The current guarantee is for 20 years, though pencils <br /> properly stored will never leak. <br /> 6. What will happen if there is no water in the pool? <br /> The radiation levels outside the concrete shield will be no <br /> different than when the source rack is in the raised <br /> position during routine production. With no water- in the <br /> pool, the in-cell radiation monitor would be in an alarm <br /> condition thus preventing entry. NRC regulations require <br /> that the means to replenish water losses from the pool be <br /> incorporated into the design. <br /> 7. Do you have any idea on cost of decontamination in case of <br /> accident? How much insurance do you carry for this purpose? <br /> For a small facility possessing less than 250,000 curies, as <br /> planned for Hawaii, with a stainless steel pool liner, the <br /> estimated cost would be in the order of $150,000. The <br /> source manufacturer would be responsible for the cost of the <br /> cleanup should the cause prove to be a manufacturing defect <br /> in the source capsule. <br /> ISOMEDIX INC. <br /> <br /> CORPORATE OFFICES • 11 APOLLO DRIVE, WHIPPANY, NEVN JERSEY 07981 • (201) 887-4700 • FAX (201) 887-1476 <br /> <br />