My WebLink
|
Help
|
About
|
Sign Out
Home
COM 0085.000 2006-2008
ClerkCouncil
>
Council Records
>
Communications
>
2006-2008
>
COM 0085.000 2006-2008
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/29/2009 2:41:07 PM
Creation date
5/8/2008 5:14:29 PM
Metadata
Fields
Template:
Communications
Communications - Type
COM
Communications - Council Term
2006-2008
Communication
0085
Point
000
Author
Bruce McClure, Public Works Director; Harry Kim, Mayor
Communications - Referred To
PWIRC
Comments
PWIRC-20: Recommends passage of Bill 23, as amended to Draft 2, on first reading - 5/1/09; PWIRC: Amended Bill 23 to Draft 2 and postponed to April 3 or when a ramseyer version of Bill 23 is submitted, whichever comes first - 2/6/07
Document Relationships
AGE PWIRC 02/06/2007 2006-2008
(Related)
Path:
\Council Records\Agendas\2006-2008\Public Works & Intergovernmental Relations Committee (PWIRC)
BIL 023 Draft 01 2006-2008
(Related To)
Path:
\Council Records\Bills\2006-2008
COM 0085.001 2006-2008
(Related To)
Path:
\Council Records\Communications\2006-2008
COM 0085.003 2006-2008
(Related To)
Path:
\Council Records\Communications\2006-2008
COM 0085.004 2006-2008
(Related To)
Path:
\Council Records\Communications\2006-2008
COM 0085.005 2006-2008
(Related To)
Path:
\Council Records\Communications\2006-2008
REP PWIRC 020 05/01/2007 2006-2008
(Related To)
Path:
\Council Records\Reports\2006-2008\Public Works & Intergovernmental Relations Committee (PWIRC)
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
14
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
<br /> Sec. 17-47, par. (39) Sec. 17-57 Adding last two sentence to <br /> EXCEPTION to read: "The fixture <br /> supply stop shall be angle valve or stop, <br /> straightway stop, screw stop, ball valve, <br /> corporation cock, butterFly valve, plug <br /> valve or similar valve. Valves shall not <br /> have slip joints on the valve inlet side" <br /> Sec. 17-47, par. (40) This Section did not exist in Adding Section 606.2.4. Copper or <br /> Secs. 17-23 to 17-124 Copper-Alloy Tubing to Galvanized <br /> Steel Pipe. Joints between copper or <br /> copper-alloy tubing and galvanized steel <br /> pipe shall be made with a brass <br /> converter fittin or dielectric fittin <br /> Sec. 17-47, par. (41) This Section did not exist in Amending Section 607.0 by adding at <br /> Secs. 17-23 to 17-124 the end of the last sentence: "or other <br /> approved method with approval of the <br /> administrative authori <br /> Sec. 17-47, par. (42) Sec. 17-58 In the first sentence change the word <br /> "County" to "city" to read: "No gravity <br /> tank shall be directly connected to the <br /> cit water main <br /> Sec. 17-47, ar. 43 Sec. 17-59 No chan e. <br /> Sec. 17-47, par. (44) This Section did not exist in Amending Section 608.3 by deleting the <br /> Secs. 17-23 to 17-124 the third paragraph. "In addition to the <br /> rewired ressurre <br /> Sec. 17-47, ar. 45 Sec. 17-60 No chan e. <br /> Sec. 17-47, ar. 46 Sec. 17-61 No chan e. <br /> Sec. 17-47, ar. 47 Sec. 17-63 No chan e. <br /> Sec. 17-47, par. (48) This Section did not exist in Amending Section 609.7.2 by changing <br /> Secs. 17-23 to 17-124 the last two sentences to read: Such an <br /> agreement shall be as a part of the <br /> conditions of ownership of said <br /> properties and shall be binding on all <br /> heirs, successors and assigns to such <br /> ro erties. <br /> Sec. 17-47, par. (49) Sec. 17-66 Deleted figures under "3 or more <br /> dwellin "and "Heav -Use Assembl ' <br /> Sec. 17-47, par. (50) This Section did not exist in New Section 60-9.10 Water Hammer. <br /> Secs. 17-23 to 17-124 All building water supply systems in <br /> which quick-acting valves are installed <br /> should be provided with devices to <br /> absorb high pressures resulting from <br /> wick closin of these valves. <br /> Sec. 17-47, ar. 51 Sec. 17.67 No chan e. <br /> Sec. 17-47, ar. 52 Sec. 17-65 No chan e. <br /> Sec. 17-47, par. (53) This Section did not exist in Deleting Section 701.1.2. ABS and <br /> Secs. 17-23 to 17-124 PVC DWV piping installations shall be <br /> limited to structures not exceeding three <br /> floors above rade. <br /> Sec. 17-47, par. (54) This Section did not exist in Amending Section 7601.3 by changing <br /> Secs. 17-23 to 17-124 the third sentence to read: "Far <br /> flashisngs or vent terminals -not less <br /> than two and one-half (2.5) pounds per <br /> square foor (12.2 Kg/square meter)." <br /> 7 <br /> <br />
The URL can be used to link to this page
Your browser does not support the video tag.