My WebLink
|
Help
|
About
|
Sign Out
Home
COM 0085.004 2006-2008
ClerkCouncil
>
Council Records
>
Communications
>
2006-2008
>
COM 0085.004 2006-2008
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/26/2009 4:30:58 PM
Creation date
5/8/2008 5:39:16 PM
Metadata
Fields
Template:
Communications
Communications - Type
COM
Communications - Council Term
2006-2008
Communication
0085
Point
004
Author
Casey Jarman, Clerk
Communications - Referred To
COUNCIL
Comments
PWIRC-20: Recommends passage of Bill 23, as amended to Draft 2, on first reading - 2/6/07; Council: Bill 23, Draft 2 amended to Draft 3 - 5/16/07
Document Relationships
AGE COUNCIL 2007/05/16 2006-2008
(Related)
Path:
\Council Records\Agendas\2006-2008\Council
BIL 023 Draft 02 2006-2008
(Related To)
Path:
\Council Records\Bills\2006-2008
COM 0085.000 2006-2008
(Related)
Path:
\Council Records\Communications\2006-2008
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
18
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
<br /> Sec. 17-47, par. (25) Sec. 17-117 Amending Section 510.1 by adding <br /> <br /> {UPC sec. 510.1.} exception "(2) Fuel burning water <br /> heaters having sealed combustion <br /> chambers may be installed at floor level. <br /> (3) Electrical water heaters in garages <br /> may be installed at floor level." <br /> Sec. 17-47, par. (26) This section did not exist in Amends Section 510.5 by changing the <br /> {UPC sec. 510.5.} secs. 17-23 to 17-124 first sentence to read: "Due to seismic <br /> activity in Hawaii County, all new water <br /> heaters shall be anchored or strapped <br /> on the top one-third (1l3) of the heater <br /> to a well anchored, structural wall, to <br /> resist horizontal displacement due to <br /> earthquake motion." <br /> Sec. 177, par. (27) This section did not exist in Amending Section 511.0 by changing <br /> {UPC sec. 511.0.} secs. 17-23 to 17-124 the first sentence to read: "Every water <br /> heater, clothes washer and clothes <br /> dryer installation should have a working <br /> space of not less than thirty (30) inches <br /> (762 mm) in front of such appliance for <br /> inspection, repair, or replacement. <br /> Sec. 17-47, par (28) This section did not exist in Amending Section 511.2 by changing <br /> {UPC sec. 511.2.} secs. 17-23 to 17-124 the first sentence to read: "Every attic, <br /> roof, mezzanine, or platform more than <br /> sixteen (16) feet (4.9 meters) above the <br /> ground floor level shall be accessible by <br /> a stairway or ladder permanently <br /> fastened to the building." <br /> Sec. 17-47, par (29) Sec. 17-118 This section was moved from sec. 17- <br /> UPC sec. 511.4. 118. No change to content. <br /> Sec. 17-47, par.(30) Sec 17-119 Adding new sections 512.9 and 512.10. <br /> {UPC sec. 512.9 & 512.10.} "...Listed single and two-family gas fired <br /> water heaters rated at less than 55,000 <br /> Btuhs need not be provided with a vent <br /> extended through the roof of the <br /> buildings or enclosure when installed <br /> outside of the exterior walls of the <br /> building unenclosed or in approved <br /> enclosures <br /> Sec. 17-47, par. (31) This section did not exist in Adding Section 601.4 to read: "601.4. <br /> {UPC sec. 601.4.} secs. 17-23 to 17-124 Private water systems. Owners of <br /> private water systems are responsible <br /> for maintaining the potability of their <br /> water s stems <br /> 7 <br /> <br />
The URL can be used to link to this page
Your browser does not support the video tag.