<br /> Sec. 17-47, par. (52) Sec. 17-67 This section was moved from sec. 17- <br /> UPC Tnble 6-5. 67. No change to content. <br /> <br /> Sec. 17-47, par. (53) Sec. 17-65 This section was moved from sec. 17- <br /> UPC sec. 610.8. 65. No change to content. <br /> Sec. 17-47, par. (54) This section did not exist in Deleting Section 701.1.2. ABS and <br /> {UPC sec. 701.1.2.} secs. 17-23 to 17-124 PVC DWV piping installations shall be <br /> limited to structures not exceeding three <br /> floors above rade. <br /> Sec. 17-47, par. (55) This section did not exist in Amending Section 701.3 by changing <br /> {UPC sec. 701.3} secs. 17-23 to 17-124 the third sentence to read: "For <br /> (lashings or vent terminals -not less <br /> than two and one-half (2.5) pounds per <br /> square foot (12.2 Kg/square meter)." <br /> Sec. 17-47, par. (56) This section did not exist in Deleting figures under "3 or more <br /> {UPC Table 7-3.} secs. 17-23 to 17-124 Dwellings" and "Heavy Use Assembly" <br /> Sec. 17-47, par. (57) Sec. 17-37 This section was moved from sec. 17- <br /> UPC sec. 703.2. 37. No change to content. <br /> Sec. 17-47, par. (58) This Section did not exist in Deleting Section 704.3. Pot sinks, <br /> Secs. 17-23 to 17-124 scullery sinks, dishwasher sinks, <br /> {UPC sec. 704.3.} <br /> Sec. 17-47, par. (59) This section did not exist in Amending Table 7-5. Table 7-5 is <br /> {UPC Table 7-5.} secs. 17-23 to 17-124 amended by adding at the end of Note <br /> 4: "or four (4) - 1.6 gallons per flush <br /> water closets on any horizontal branch <br /> or drain." <br /> Sec. 17-47, par. (60) Sec. 17-38 This section was moved from sec. 17- <br /> UPC sec. 707.4. 38. No change to content. <br /> Sec. 17-47, par. (61) Sec. 17-38 This section was moved from sec. 17- <br /> {UPC sec. 707.4.} 38. No change to content. <br /> Sec. 17-47, par. (62) This section did not exist in Amending Section 707.12 by adding to <br /> {UPC sec. 707.12.} secs. 17-23 to 17-124 the end of the last sentence: "or other <br /> engineered design method with the <br /> approval of the administrative authority. <br /> Sec. 17-47, par. (63) Sec. 17-40 This section was moved from sec. 17- <br /> {UPC sec. 707.15.} 40. No change to content. <br /> Sec. 17-47, par. (64) This section did not exist in Amending Section 710.1 by adding <br /> {UPC sec. 710.1.} secs. 17-23 to 17-124 second sentence: "Where such <br /> upstream manhole cover does not exist, <br /> an approved backwater valve shall be <br /> installed if the fixtures have flood level <br /> rims below the connecting manhole <br /> cover." <br /> Sec. 17-47, par. (65) This section did not exist in Adding Section 710.3.4 to read: <br /> {UPC sec. 710.3.4.} secs. 17-23 to 17-124 "Macerating or grinder type sump <br /> pumps shall have a minimum pipe size <br /> of one and one fourth (1-1/4) inches." <br /> 10 <br /> <br />