<br /> <br /> <br /> <br /> <br /> <br /> <br /> (2) Amending Section 101.5.2. Section 101.5.2 is amended to read: <br /> <br /> "Section 101.5.2 Low energy buildings. Buildings, or portions thereof, separated from the <br /> remainder of the building by building thermal envelope assemblies complying with this <br /> code and with a peak design rate of energy usage less than 3.4 Btu/h•ft2 (10.7 W/ m2) or <br /> 1.0 watt/ft2 (10.7 W/m2) of floor area for space conditioning purposes shall be exempt <br /> from the building thermal envelope provisions of this code." <br /> <br /> (3) Amending Section 202. Section 202, General Definitions, is amended by adding a <br /> definition for "Fully Shaded Windows" to read: <br /> <br /> "FULLY SHADED WINDOWS. Windows protected from direct solar heat gain by a <br /> projection factor of no less than 1.0." <br /> <br /> <br /> (4) Amending Section 401.1. Section 401.1 is amended to read: <br /> <br /> "401.1 Scope. This chapter applies to residential buildings, including those that do not <br /> contain conditioned space." <br /> <br /> <br /> (5) Amending Table 402.1.1. Footnote h is added to Table 402. 1.1 to read: <br /> <br /> "TABLE 402. 1.1 INSULATION AND FENESTRATION REQUIREMENTS BY COMPONENT <br /> <br /> Climate Fenestration Skylight Glazed Ceiling R- Wood Mass Floor Basement` Slab Crawl <br /> Zone U-Factor U-Factor Fenestration Value Frame Wall R-Value Wall R-Value Space <br /> SHGC Wall R-Value R-Value & Depth Wall <br /> R-Value R-Value <br /> 1 1.20 0.75 0.40 30 13 3 13 0 0 0 <br /> 2 0.75 0.75 0.40 30 13 4 13 0 0 0 <br /> 3 0.65 0.65 0.40e 30 13 5 19 0 0 5 /13 <br /> 4 0.40 0.60 NR 38 13 5 19 10/ 13 10, 2 ft 10 / 13 <br /> except <br /> Marine <br /> 5 and 0.35 0.60 NR 38 19 or 13 30 10/ 13 10, 2 ft 10/ 13 <br /> Marine 13+59 <br /> 4 <br /> 6 0.35 0.60 NR 49 19 or 15 30 10/ 13 10, 4 it 10 / 13 <br /> 13+56 <br /> 7 and 8 0.35 0.60 NR 49 21 19 30 10 /13 10.4 ft 10/ 13 <br /> For SI: 1 foot = 304.8 mm. <br /> a. R-values are minimums. U-factors and SHGC are maximums. R-19 shall be permitted <br /> to be compressed into a 2 x 6 cavity. <br /> b. The fenestration U-factor column excludes skylights. The SHGC column applies to all <br /> glazed fenestration. <br /> c. The first R-value applies to continuous insulation, the second to framing cavity <br /> insulation; either insulation meets the requirement. <br /> 2 <br />