My WebLink
|
Help
|
About
|
Sign Out
Home
COM 0141.006 2008-2010
ClerkCouncil
>
Council Records
>
Communications
>
2008-2010
>
COM 0141.006 2008-2010
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/6/2009 9:59:31 AM
Creation date
3/6/2009 9:59:30 AM
Metadata
Fields
Template:
Communications
Communications - Type
COM
Communications - Council Term
2008-2010
Communication
0141
Point
006
Author
Pete Hoffmann, Council Vice Chair
Communications - Referred To
PWIRC
Document Relationships
AGE PWIRC 03/17/2009 2008-2010
(Related)
Path:
\Council Records\Agendas\2008-2010\Public Works & Intergovernmental Relations Committee (PWIRC)
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
18
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
<br /> <br /> <br /> <br /> <br /> <br /> <br /> (8) Amending Section 402.2.2. Section 402.2.2 is amended to read: <br /> "402.2.2 Ceilings without attic spaces. Where Section 402.1.1 would require insulation <br /> levels above R-30 and the design of the roof/ceiling assembly does not allow sufficient <br /> space for the required insulation, the minimum required insulation for such roof/ceiling <br /> assemblies shall be R-19." <br /> <br /> <br /> (9) Amending Section 402.3.3. Section 402.3.3 is amended to read: <br /> <br /> "402.3.3 Glazed fenestration exemption. Fully shaded windows, north-facing windows <br /> and up to 15 square feet (1.4 m2) of glazed fenestration per dwelling unit shall be <br /> permitted to be exempt from U-factor and SHGC requirements in Section 402.1.1." <br /> <br /> <br /> (10) Amending Section 402.4.1. Section 402.4.1 is amended by adding Section 402.4.1.1 to <br /> read: <br /> <br /> "402.4.1.1. Non-conditioned building exemption. Non-conditioned residential buildings <br /> are exempt from compliance with Section 402.4. The free-vent fenestration area of non- <br /> conditioned buildings shall be no less than 14 percent of the floor area. All interior doors <br /> shall be capable of being secured in the open position and ceiling fan stub-ins shall be <br /> provided to living areas and bedrooms." <br /> <br /> <br /> (11) Amending Section 402.4.2. Section 402.4.2 is amended to read: <br /> <br /> "402.4.2 Fenestration air leakage. Windows, skylights and sliding glass doors shall have <br /> an air infiltration rate of no more than 0.3 cfm per square foot (1.5 L/s/m2), and swinging <br /> doors no more than 0.5 cfm per square foot (2.6 L/s/m2), when tested according to NFRC <br /> 400 or AAMA/WDMA/CSA 101/I.S.2/A440 by an accredited, independent laboratory <br /> and listed and labeled by the manufacturer. <br /> Exceptions: <br /> 1. Site-built windows, skylights and doors; <br /> 2. Jalousie windows shall not exceed 1.2 cfm per square foot (6.1 L/s/m2)." <br /> <br /> <br /> (12) Amending Section 403. Section 403 is amended by adding Section 403.7 to read: <br /> <br /> "403.7 Residential pools. Residential pools shall be provided with energy conserving <br /> measures in accordance with Sections 403.7.1 through 403.7.3. <br /> 403.7.1 Pool heaters. All pool heaters shall be equipped with a readily accessible <br /> on-off switch to allow shutting off the heater without adjusting the thermostat setting. Pool <br /> heaters fired by natural gas shall not have continuously burning pilot lights. <br /> <br /> <br /> <br /> <br /> 6 <br /> I <br />
The URL can be used to link to this page
Your browser does not support the video tag.