My WebLink
|
Help
|
About
|
Sign Out
Home
BIL 025 Draft 02 1996-1998
ClerkCouncil
>
Council Records
>
Bills
>
1996-1998
>
BIL 025 Draft 02 1996-1998
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/2/2017 7:33:25 AM
Creation date
3/18/2009 12:21:54 PM
Metadata
Fields
Template:
Bill/Resolution
Bill/Resolution - Type
BIL
Bill/Resolution - Council Term
1996-1998
Bill/Resolution
026
Draft
02
Introducer
Dominic Yagong, Councilmember
Referred To
COUNCIL
Action 1
Council: Passes Bill 25, Dr. 2 on 1st reading & adopts PWPC-10 - 02/07/97 (MB 464)
Action 2
Council: Passes Bill 25 on 2nd and final reading - 02/19/97
Status
Adopted
Date To Mayor or Adoption Date
4/1/1997
Reading Number
1
Reading Date
2/7/1997
Ayes
9-Arakaki;Chung;Leithead-Todd;Ray;Reynolds;Santangelo;Smith;Tyler;Yagong
Noes
0-
Absent
0-
Excused
0-
Reading Number .
2
Reading Date .
2/19/1997
Ayes .
9-Arakaki;Chung;Leithead-Todd;Ray;Reynolds;Santangelo;Smith;Tyler;Yagong
Noes .
0-
Absent .
0-
Excused .
0-
Document Relationships
AGE COUNCIL 02/07/1997 1996-1998
(Related)
Path:
\Council Records\Agendas\1996-1998\Council
AGE COUNCIL 02/19/1997 1996-1998
(Related)
Path:
\Council Records\Agendas\1996-1998\Council
COM 0075.000 1996-1998
(Related)
Path:
\Council Records\Communications\1996-1998
ORD 1997-026 1996-1998
(Related)
Path:
\Council Records\Ordinances\1997
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
14
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
<br />. <br /> <br />. <br /> <br />(B) <br /> <br />Exce~tions. <br />(i) Desim load calculations need not be submitted for new. individually <br />permitted. coolin~ Systems of less than 65.000 Btu/hr caoacitv that <br />provide less than 37 Btu/hr of installed capacitv per square foot of <br />conditioned floor area. . <br />(ii) Desif!!' load calculations need not be submitted when existine: <br />cooling eq~ipment is replaced with equipment of equal or less capacity." <br /> <br />SECTION 13. Section 5-2.9.3.(g) of the Hawaii County Code 1983 (1995 Edition) relating <br />to Materials and Construction is hereby amended so that Table 9-1 relating to . <br />Minimum Pipe Insulation reads as follows: <br /> <br />Table 9-1 <br />Minimum Pipe Insulation (lnches)- <br /> <br />Insulation Conductivity Nominal Pipe Diameter (Inches) <br />Fluid Design Mean <br />Operating Temp., Condo Range, RadDg Runoutsb land Sand <br />Range OF Btu . inlb . ft3 . OF Temp., 0 upto2 less 1.25 to 2 2.S to 4 Sand' up <br /> F <br />Heating Systems (Steam, Steam Condensate, and Hot Water) . <br />Above 350 0.32-0.34 250 1.5 2.5 2.5 3.0 3.5 3.5 <br />251-350 0.29-0.31 200 1.5 2.0 2.5 2.5 3.5 3.5 <br />201-250 0.27-0.30 150 1.0 1.5 1.5 2.0 2.0 3.5 <br />141-200 0.25-0.29 125 . 0.5 1.5 1.5 1.5 1.5 1.5 <br />105-140 0.24-0.28 100 0.5 1.0 1.0 1.0 1.5 I.S <br />Domestic and Service Hot Water <br />105 and greater 0.24-0.28 . 100 0.5 1.0 1.0 1.5 1.5 1.5 <br />Cooling Systems (Chilled Water, Brine and Refrigerant)d <br />40-55 0.23-0.27 75 0.5 0.5 0.75 1.0 1.0 1.0 <br />Below 40 0.23-0.27 75 1.0 1.0 1.5 1.5 1.5 I.S <br /> <br />Notes: <br />a. For minimum thicknesses of alternative insulation types, see section 5-2.9.3(g)(2). <br />b. Runouts to individual terminal units not exceeding 12 feet in length. <br />c. Applies to recirculation sections of service or domestic hot water systems and first 8 feet of hot water piping from <br />storage tank for nonrecirculating systems. <br />d. The required minimum thicknesses do not consider water vapor transmission and condensation. Additional insulation <br />and/or vapor retarders may be required to limit water vapor transmission and condensation. <br /> <br />13 <br />
The URL can be used to link to this page
Your browser does not support the video tag.