My WebLink
|
Help
|
About
|
Sign Out
Home
COM 0875.001 2008-2010
ClerkCouncil
>
Council Records
>
Communications
>
2008-2010
>
COM 0875.001 2008-2010
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/20/2010 3:04:15 PM
Creation date
7/23/2010 9:58:08 AM
Metadata
Fields
Template:
Communications
Communications - Type
COM
Communications - Council Term
2008-2010
Communication
0875
Point
001
Author
Kenneth G. Goodenow, County Clerk
Communications - Referred To
PWIRC
Comments
PWIRC: Close file - 08/03/10 Council: Close file - 09/09/10
Document Relationships
AGE COUNCIL 09/09/2010 2008-2010
(Related To)
Path:
\Council Records\Agendas\2008-2010\Council
AGE PWIRC 08/03/2010 2008-2010
(Related)
Path:
\Council Records\Agendas\2008-2010\Public Works & Intergovernmental Relations Committee (PWIRC)
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
17
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
(5) <br />each such bed shall be at least fifty (50) percent greater than the <br />tabular requirements for trenches. Perimeter sidewall arca in <br />excess of the required twelve (12) inches (305 mm) and not to <br />exceed thirty six (36) inches (914 mm) below the leach line may <br />be added to the trench <br />i0 - . <br />(3) No excavation for a 1 ach line or leach bed shall extend within five <br />(5) feet (1,521 mm) of the water table nor to a depth where sewage <br />may contaminate the underground water stratum that is usable for <br />domestic purposes. <br />(1,521 mm) separation requirement may bc reduced by the <br />Authority Having Jurisdiction. The applicant shall supply <br />(1) The minimum effective absorption area in any scepage pit shall be <br />calculated as the excavated sidewall area below the inlet exclusive <br />of any hardpan, rock, clay, or other impervious formations. The <br />minimum required area of porous formation shall be provided in <br />(10) feet (3, 048 mm) of the water table nor to a depth where <br />sewage may contaminate underground water stratum that is usable <br />for domestic purposcs. <br />the groundwaters arc grossly degraded, the ten (10) foot <br />(3,018 mm) separation requirement may be reduced by the <br />Authority Having Jurisdiction. The applicant shall supply <br />evidence of groundwater depth to the satisfaction of the <br />Authority Having Jurisdiction. <br />L aching chambers shall be sized on the bottom absorption area <br />(nominal unit width) in square fcct. The required area shall bc <br />- .1. 1.. <br />(31) Amending Section K4 (C). Appendix K is amended by amending the <br />first sentence of Section K4 (C) to read: <br />"(C) When a percolation test is required, the test shall be conducted at a <br />minimum depth of three feet, and no private disposal system shall be <br />permitted to serve a building if that test shows the absorption capacity <br />of the soil is less than 0.83 gallons per square foot (33.8 L /m or more <br />than 5.12 gallons per square foot (208 L /m of leaching area per 24 <br />hours." <br />1" <br />id' 17 <br />„; c! I„r n rn,, nrr,n 7)H6 1 l'( los p,•c,riciccl i„ liill 2(69 <br />
The URL can be used to link to this page
Your browser does not support the video tag.