My WebLink
|
Help
|
About
|
Sign Out
Home
COM 0874.002 2008-2010
ClerkCouncil
>
Council Records
>
Communications
>
2008-2010
>
COM 0874.002 2008-2010
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/20/2010 2:09:45 PM
Creation date
8/27/2010 1:50:18 PM
Metadata
Fields
Template:
Communications
Communications - Council Term
2008-2010
Communication
0874
Point
002
Author
Warren H.W. Lee, P.E., Director of Public Works
Communications - Referred To
COUNCIL
Comments
Council: Close file - 09/09/10
Document Relationships
AGE COUNCIL 09/09/2010 2008-2010
(Related To)
Path:
\Council Records\Agendas\2008-2010\Council
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
20
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
2. Ground Fault Protection: <br /> a. Approved ground fault circuit protection shall be provided for all <br /> feeder and branch circuits below or extending into inundation <br /> level. <br /> 3. Wiring Method and Material: <br /> a. Distribution Equipment. Equipment such as transformers, fuses, <br /> panelboards, switchboards, disconnects, circuit breakers, <br /> controllers and other devices used for control, disconnecting <br /> means, ground fault protection, or overcurrent protection shall be <br /> located above the inundation level, unless made of water -tight <br /> construction. <br /> 4. The director of public works shall have the authority to consider <br /> exceptions to the provisions of the requirements of this section and may <br /> grant variance from the provisions thereof, if local topographic <br /> conditions clearly indicate that the possibility of flooding is not present. <br /> 5. Contractor will provide a certified bench mark on jobsite for flood zone <br /> elevation reference point. <br /> 6. Residential and nonresidential electrical only permit application <br /> requirements: Electrical design drawings stamped and signed by an <br /> electrical engineer registered in the State of Hawai`i. Plans shall <br /> include a site or plot plan showing the certified flood zone elevation <br /> mark. <br /> [Section 9 -25. • .. • • , • • _ .. • , • , • . • • • • .. • • , <br /> . Reserved. <br /> SECTION 14. Chapter 9, article 5, division 1, section 9 -26 of the Hawai`i County Code <br /> 1983 (2005 Edition, as amended) is amended to read as follows: <br /> "Section 9 -26. Permit required; exceptions. <br /> No person shall perform any electrical work or cause or permit the same to be done, <br /> unless a permit therefor has been obtained from the administrative authority with the <br /> following exceptions: <br /> (1) Electric work and installations to which the provisions of this chapter are <br /> expressly declared to be not applicable. <br /> 15 <br />
The URL can be used to link to this page
Your browser does not support the video tag.