Laserfiche WebLink
As amended, Table 16 -1 shall read: <br /> "Table 16 -1 <br /> Location of Gray Water System <br /> Minimum Horizontal Distance Holding Tank Irrigation/ <br /> in Clear Required From: Feet (mm) Disposal Field <br /> Feet (mm) <br /> Building structures' 5 (1,524 mm) 5 (1,524 mm) <br /> Property line adjoining private 5 (1,524 mm) 5 (1,524 mm) <br /> property <br /> Water supply wells 50 (15,240 mm) 1000 (304,800 mm) <br /> Streams and lakes 50 (15,240 mm) 50 (15,240 mm) <br /> Sewage pits or cesspools 5 (1,524 mm) 5 (1,524 mm) <br /> Disposal field 5 (1,524 mm) 5 (1,524 mm) <br /> Septic tank 0 (0) 5 (1,524 mm) <br /> 1 On -site domestic water service line 5 (1,524 mm) 5 (1,524 mm) <br /> Pressurized public water main 10 (3,048 mm) 10 (3,048 mm) <br /> Note: When irrigation /disposal fields are installed in sloping ground, the minimum horizontal distance between any <br /> part of the distribution system and the ground surface shall be fifteen (15) feet (4,572 mm). <br /> Including porches and steps, whether covered or uncovered, breezeways, roofed porte cocheres, roofed patios, <br /> carports, covered walks, covered driveways, and similar structures or appurtenances. <br /> The distance may be reduced to zero feet for aboveground tanks when first approved by the authority having <br /> jurisdiction. <br /> Where special hazards are involved, the distance required shall be increased as may be directed by the authority <br /> having jurisdiction. <br /> a These minimum clear horizontal distances shall also apply between the irrigation /disposal field and the ocean <br /> mean higher hightide line. <br /> s For parallel construction /for crossings, approval by the authority having jurisdiction shall be required." <br /> 12 <br />