My WebLink
|
Help
|
About
|
Sign Out
Home
BIL 269 Draft 03 2008-2010
ClerkCouncil
>
Council Records
>
Bills
>
2008-2010
>
BIL 269 Draft 03 2008-2010
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/7/2011 2:18:02 PM
Creation date
7/12/2011 9:49:10 AM
Metadata
Fields
Template:
Bill/Resolution
Bill/Resolution - Type
BIL
Bill/Resolution - Council Term
2010-2012
Bill/Resolution
269
Draft
03
Introducer
Dominic Yagong, Council Member
Referred To
COUNCIL
Action 1
Council: Bill 269, Draft 3 passes first reading; adopts PWPRC-21 - 07/07/11
Action 2
Council: Bill 269, Draft 3 passes second & final reading - 07/22/11
Status
Adopted
Date To Mayor or Adoption Date
8/2/2011
Reading Number
1
Reading Date
7/7/2011
Ayes
8-Blas;Ford;Hoffmann;Ikeda;Onishi;Smart;Yagong;Yoshimoto
Noes
0
Absent
1-Pilago
Excused
0
Reading Number .
2
Reading Date .
7/22/2011
Ayes .
9-Blas;Ford;Hoffmann;Ikeda;Onishi;Pilago;Smart;Yagong;Yoshimoto
Noes .
0
Absent .
0
Excused .
0
Document Relationships
AGE COUNCIL 07/22/2011 2010-2012
(Related To)
Path:
\Council Records\Agendas\2010-2012\Council
COM 0127.002 2010-2012
(Related)
Path:
\Council Records\Communications\2010-2012
COM 0127.002 2010-2012
(Related To)
Path:
\Council Records\Communications\2010-2012
ORD 2011-070 2010-2012
(Related To)
Path:
\Council Records\Ordinances\2011
ORD 2011-070 2010-2012
(Related)
Path:
\Council Records\Ordinances\2011
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
19
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
(B) Standards for a mini -leach field system: <br /> (1) Perforated sections shall be a minimum three (3) inch (80 mm) <br /> diameter and shall be constructed of perforated high- density <br /> polyethylene pipe, perforated ABS pipe, perforated PVC pipe, or other <br /> approved materials, provided that sufficient openings are available for <br /> distribution of the gray water in to the trench area. Material, <br /> construction, and perforation of the pipe shall be in compliance with the <br /> appropriate absorption fields drainage piping standards and shall be <br /> approved by the Health Officer. <br /> (2) Filter material, clean stone, gravel, slag, or similar filter material <br /> acceptable to the authority having jurisdiction, varying in size from <br /> three - quarter (3/4) inch (20 mm) to two and one -half (2 -1/2) inch (65 <br /> mm) shall be placed in the trench to the depth and grade required by <br /> this section. The perforated section shall be laid on the filter material in <br /> an approved manner. The perforated section shall then be covered with <br /> filter material to the minimum depth required by this section. The filter <br /> material shall then be covered with untreated building paper, straw, or <br /> similar porous material to prevent closure of voids with earth backfill. <br /> No earth backfill shall be placed over the filter material cover until after <br /> inspection and acceptance." <br /> (21) Deleting Chart for Section 1611.0 (C). The corresponding chart for Section <br /> 1611.0 (C) is deleted. <br /> (22) Amending Section 1612.0 (A). Section 1612.0 (A) is amended to read: <br /> "(A) Other collection and distribution systems such as laundry only gray water <br /> systems may be approved by the local Health Officer." <br /> (23) Amending Table 16 -1. Table 16 -1, Location of Gray Water Systems, is amended as <br /> follows: <br /> A) Deleted "100% expansion area" as relating to "Disposal Field." <br /> B) Changed the values for the following Irrigation/Disposal Field: <br /> - Building Structures <br /> - Water Supply Wells <br /> - Disposal Field <br /> 11 <br />
The URL can be used to link to this page
Your browser does not support the video tag.