My WebLink
|
Help
|
About
|
Sign Out
Home
COM 0128.074 2010-2012
ClerkCouncil
>
Council Records
>
Communications
>
2010-2012
>
COM 0128.074 2010-2012
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/3/2011 3:08:14 PM
Creation date
10/5/2011 8:02:12 AM
Metadata
Fields
Template:
Communications
Communications - Type
COM
Communications - Council Term
2010-2012
Communication
0128
Point
074
Author
Brittany Smart, Council Member
Communications - Referred To
COUNCIL
Comments
Council: Held over - 10/05/11 Council: Postponed - 10/19/11 Council: Close file - 11/02/11
Document Relationships
AGE COUNCIL 10/19/2011 2010-2012
(Related To)
Path:
\Council Records\Agendas\2010-2012\Council
AGE COUNCIL 11/02/2011 2010-2012
(Related To)
Path:
\Council Records\Agendas\2010-2012\Council
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
8
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
TABLE 1609.1.2 <br />WIND -BORNE DEBRIS PROTECTION FASTENING SCHEDULE <br />FOR WOOD STRUCTURAL PANELS a,b,c <br />FASTENER TYPE <br />FASTENER SPACING <br />Panel span <br /><_ 4 feet <br />4 feet <br />< Panel span <br /><_ 6 feet <br />6 feet <br />< Panel span <br /><_ 8 feet <br />No. 6 screws <br />16" <br />12" <br />9" <br />No. 8 screws <br />16" <br />16" <br />12" <br />For SI: 1 inch = 25.4 mm, 1 foot = 304.8 mm, 1 pound = 0.454 kg, <br />1 mile per hour = 1.609 km /h. <br />a. This table is based on a maximum wind speed (3- second gust) of 130 mph and mean roof <br />height of 33 feet or less. <br />b. Fasteners shall be installed at opposing ends of the wood structural panel. Fasteners shall <br />be located a minimum of 1 inch from the edge of the panel. <br />c. Fasteners shall be long enough to penetrate through the exterior wall covering a minimum of <br />1.75 inches into wood wall framing; a minimum of 1.25 inches into concrete block or concrete; <br />or into steel framing by at least three threads. Fasteners shall be located a minimum of 2.5 <br />inches from the edge of concrete block or concrete. <br />d. Where screws are attached to masonry or masonry/stucco, they shall be attached utilizing <br />vibration - resistant anchors having a minimum withdrawal capacity of 490 pounds." <br />8. Bill No. 270, Draft 3, is amended by adding a section 5 -85 to read as follows: <br />"Section 5 -85. Exemption from International Energy Conservation Code; as adopted and amended. <br />Non - conditioned R -3 structures are exempted from this article." <br />No draft copy of Bill No. 270, Draft 4, is attached in an effort to conserve resources. <br />BLS <br />
The URL can be used to link to this page
Your browser does not support the video tag.