Laserfiche WebLink
(1) The building permit number. <br />(2) The address of the structure. <br />(3) The name and address of the owner. <br />(4) A description of that portion of the structure for which the certificate is issued. <br />(5) A statement that the described portion of the structure has been inspected for compliance with <br />the requirements of this code for the occupancy and division of occupancy and the use for <br />which the proposed occupancy is classified. <br />(6) The name of the building official. <br />(7) The edition of the code under which the permit was issued. <br />(8) The use and occupancy, in accordance with the provisions of chapter 3. <br />(9) The type of construction as defined in chapter 6. <br />(10) The design occupant Toad. <br />(11) If an automatic sprinkler system is provided, whether the sprinkler system is required. <br />(12) Any special stipulations and conditions of the building permit. <br />(c) Temporary Certificate. The building official is authorized to issue a temporary certificate of <br />occupancy before the completion of the entire work covered by the permit, provided that such <br />portion or portions shall be occupied safely. The building official shall set a time period during <br />which the temporary certificate of occupancy is valid. <br />(d) Revocation. The building official is authorized to, in writing, suspend or revoke a certificate of <br />occupancy or completion issued under the provisions of this code wherever the certificate is issued <br />in error, or on the basis of incorrect information supplied, or where it is determined that the building <br />or structure or portion thereof is in violation of any ordinance or regulation or any of the provisions <br />of this code. <br />Section 5 -46. Reserved. <br />Section 5 -47. Reserved. <br />Division 6. Substandard and Unsafe Buildings. <br />Section 5 -48. Substandard buildings. <br />Any building or portion thereof in which there exists any of the following listed conditions to an <br />extent that it endangers the life, limb, health, property, safety or welfare of the public or the occupants <br />thereof shall be deemed and hereby is declared to be a "substandard building:" <br />(1) Inadequate sanitation shall include but not limited to the following: <br />(A) Lack of, or improper water closet, lavatory, bathtub or shower in a dwelling unit. <br />(B) Lack of, or improper water closets, lavatories, and bathtubs or showers in a hotel. <br />(C) Lack of, or improper kitchen sink in a habitable building. <br />(D) Lack of hot and cold water to basins, sinks, tubs and showers in R -1 Occupancies. <br />(E) Lack of hot and cold water to basins, sinks, tubs and showers in a dwelling unit or <br />efficiency living unit. <br />(F) Lack of, or improper operation of required ventilating equipment. <br />(G) Lack of minimum amounts of natural light and ventilation required by this code. <br />(H) Room area or space dimensions less than the minimum required by this code. <br />15 <br />