My WebLink
|
Help
|
About
|
Sign Out
Home
ORD 2020-010 2018-2020
ClerkCouncil
>
Council Records
>
Ordinances
>
2020
>
ORD 2020-010 2018-2020
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/5/2020 1:36:10 PM
Creation date
2/5/2020 1:34:55 PM
Metadata
Fields
Template:
Ordinances
Ordinances - Type
ORD
Ordinances - Council Term
2018-2020
Year
2020
Ordinance
010
Effective Date
2/4/2020
Document Relationships
BIL 126 Draft 01 2018-2020
(Related)
Path:
\Council Records\Bills\2018-2020
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
31
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
(30) Subsection R401.3 of the International Energy Conservation Code is amended to read <br /> as follows: <br /> "R401.3 Certificate (Mandatory).A permanent certificate shall be completed by the <br /> builder or registered design professional and posted on a wall in the space where the <br /> furnace is located, a utility room or an approved location inside the building. Where <br /> located on an electrical panel, the certificate shall not cover or obstruct the visibility <br /> of the circuit directory label, service disconnect label or other required labels. The <br /> certificate shall [list]: <br /> 1. List the predominant R-values of insulation installed in or on ceiling/roof, <br /> walls, [foundation(slab, basement wall, crawlspace wall and floor)] and ducts <br /> outside conditioned spaces; U-factors for fenestration and the solar heat gain <br /> coefficient (SHGC) of fenestration, and the results from any required duct <br /> system and building envelope air leakage testing done on the building. Where <br /> there is more than one value for each component, the certificate shall list the <br /> value covering the largest area. [The certificate shall list] <br /> 2. List the types and efficiencies of heating, cooling and service water heating <br /> equipment. Where a gas-fired unvented room heater, electric furnace or <br /> baseboard electric heater is installed in the residence, the certificate shall list <br /> "gas-fired unvented room heater," "electric furnace" or"baseboard electric <br /> heater," as appropriate. An efficiency shall not be listed for gas-fired unvented <br /> room heaters, electric furnaces or electric baseboard heaters. <br /> 3. Indicate which areas have been designed and constructed as conditioned or <br /> unconditioned space. <br /> 4. Include the following text: "The addition of mechanical cooling or heating to <br /> an unconditioned space requires a building permit. The addition of cooling <br /> without proper design and construction can have adverse health, safety, and <br /> conservation consequences."" <br /> (31) Subsection R402.1 of the International Energy Conservation Code is amended to read <br /> as follows: <br /> "R402.1 General (Prescriptive). <br /> The building thermal envelope shall meet the requirements of Sections R402.1.1 <br /> through R402.1.5. <br /> Exception: The following low-energy buildings, or portions thereof, separated <br /> from the remainder of the building by building thermal envelope assemblies <br /> complying with this section shall be exempt from the building thermal envelope <br /> provisions of Section R402. <br /> 17 <br />