My WebLink
|
Help
|
About
|
Sign Out
Home
ORD 2020-010 2018-2020
ClerkCouncil
>
Council Records
>
Ordinances
>
2020
>
ORD 2020-010 2018-2020
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/5/2020 1:36:10 PM
Creation date
2/5/2020 1:34:55 PM
Metadata
Fields
Template:
Ordinances
Ordinances - Type
ORD
Ordinances - Council Term
2018-2020
Year
2020
Ordinance
010
Effective Date
2/4/2020
Document Relationships
BIL 126 Draft 01 2018-2020
(Related)
Path:
\Council Records\Bills\2018-2020
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
31
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
[ ] <br /> Fuel type: Electric <br /> Cooling systems'f Efficiency: in accordance with prevailing federal As proposed <br /> minimum standards. <br /> Capacity: sized in accordance with Section R403.7. As proposed <br /> [As-PreP ] [ d] <br /> Fuel type: same as proposed design As proposed <br /> Service water heatingd°e, Efficiency: in accordance with prevailing federal As proposed <br /> f,g minimum standards. <br /> Use: Same as proposed design gal/day=30 + <br /> (10 x NO. <br /> Duct insulation: From Section R403.2.1 <br /> As tested or as <br /> A thermal distribution system efficiency(DSE) of 0.88 specified in Table <br /> Thermal distribution shall be applied to both the heating and cooling system R405.5.2(2) if not <br /> systems efficiencies for all systems other than tested duct tested. Duct <br /> systems. For tested duct systems,the leakage rate shall insulation shall be <br /> be 4 cfm (113.3 L/min)per 100 ft (9.29 m2) of as proposed. <br /> conditioned floor area at a pressure of differential of 0.1 <br /> inches w.g. (25 Pa). <br /> Thermostat Type: Manual, cooling temperature setpoint= 75°F; Same as standard <br /> Heating temperature setpoint= 72°F reference <br /> For SI: 1 square foot=0.93 m2, 1 British thermal unit= 1055 J, 1 pound per square foot=4.88 kg/m2, <br /> 1 gallon(US)=3.785 L, °C=(°F-32)/1.8, 1 degree=0.79 rad. <br /> a. Where required by the code official,testing shall be conducted by an approved party. Hourly calculations <br /> as specified in the ASHRAE Handbook of Fundamentals, or the equivalent shall be used to determine the <br /> energy loads resulting from infiltration. <br /> b. The combined air exchange rate for infiltration and mechanical ventilation shall be determined in <br /> accordance with Equation 43 of 2001 ASHRAE Handbook of Fundamentals,page 26.24 and the"Whole- <br /> house Ventilation"provisions of 2001 ASHRAE Handbook of Fundamentals,page 26.19 for intermittent <br /> mechanical ventilation. <br /> c. Thermal storage element shall mean a component not part of the floors,walls or ceilings that is part of a <br /> passive solar system,and that provides thermal storage such as enclosed water columns,rock beds, or <br /> phase-change containers.A thermal storage element must be in the same room as fenestration that faces <br /> within 15 degrees(0.26 rad)of true south, or must be connected to such a room with pipes or ducts that <br /> allow the element to be actively charged. <br /> d. For a proposed design with multiple heating, cooling or water heating systems using different fuel types, <br /> the applicable standard reference design system capacities and fuel types shall be weighted in accordance <br /> with their respective loads as calculated by accepted engineering practice for each equipment and fuel type <br /> present. <br /> e. For a proposed design without a proposed heating system,a heating system with the prevailing federal <br /> minimum efficiency shall be assumed for both the standard reference design and proposed design. <br /> f. For a proposed design home without a proposed cooling system, an electric air conditioner with the <br /> prevailing federal minimum efficiency shall be assumed for both the standard reference design and the <br /> proposed design. <br /> g. For a proposed design with a nonstorage-type water heater,a 40-gallon storage-type water heater with the <br /> prevailing federal minimum energy factor for the same fuel as the predominant heating fuel type shall be <br /> assumed. For the case of a proposed design without a proposed water heater, a 40-gallon storage-type <br /> water heater with the prevailing federal minimum efficiency for the same fuel as the predominant heating <br /> fuel type shall be assumed for both the proposed design and standard reference design. <br /> h. For residences with conditioned basements, R-2 and R-4 residences and townhouses,the following formula <br /> shall be used to determine glazing area: <br /> 24 <br />
The URL can be used to link to this page
Your browser does not support the video tag.