My WebLink
|
Help
|
About
|
Sign Out
Home
ORD 2020-010 2018-2020
ClerkCouncil
>
Council Records
>
Ordinances
>
2020
>
ORD 2020-010 2018-2020
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/5/2020 1:36:10 PM
Creation date
2/5/2020 1:34:55 PM
Metadata
Fields
Template:
Ordinances
Ordinances - Type
ORD
Ordinances - Council Term
2018-2020
Year
2020
Ordinance
010
Effective Date
2/4/2020
Document Relationships
BIL 126 Draft 01 2018-2020
(Related)
Path:
\Council Records\Bills\2018-2020
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
31
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
3. The requirements of Sections C402.5, C403.2, C404, C405.2, C405.3, C405.5, <br /> C405.6 and C407. The building energy cost shall be equal to or less than 85 <br /> percent of the standard reference design building. <br /> Exception: For buildings 2,500 square feet or less with 4 tons of cooling or less <br /> where it is determined by the code official that the building configuration is <br /> similar to that of a residential building, the requirements in Sections R401.2.1 <br /> Tropical Zone shall be permitted to be used." <br /> (8) Subsection C402.1.1 of the International Energy Conservation Code is amended to <br /> read as follows: <br /> "C402.1.1 Low-energy use buildings. The following low-energy use buildings, or <br /> portions thereof separated from the remainder of the building by building thermal <br /> envelope assemblies complying with this section, shall be exempt from the building <br /> thermal envelope provisions of Section C402. <br /> 1. Those with a peak design rate of energy usage less than 3.4 Btu/h•ft2 (10.7 <br /> W/m2) or 1.0 watt per square foot (10.7 W/m2) of floor area for space <br /> conditioning purposes. <br /> 2. [ -: - -. : : -: : - .'- : •: ' ': ••: •] Unconditioned space that does <br /> not contain occupiable space and/or habitable space. <br /> 3. Greenhouses. <br /> 4. Open park pavilions where there is no enclosed space." <br /> (9) Table C402.1.3 from the International Energy Conservation Code is deleted in its <br /> entirety and replaced with the following: <br /> "TABLE C402.1.3 <br /> OPAQUE THERMAL ENVELOPE INSULATION COMPONENT <br /> MINIMUM REQUIREMENTS,R-VALUE METHOD'- CLIMATE ZONE 1 <br /> CLIMATE ZONE 1 <br /> All other Group R <br /> Roofs <br /> . Insulation entirely <br /> above roof deck R-l Oci R-12.S ci <br /> Metal buildingsa'b R-30 or R-19 with cool roof R-30 or R-19 with cool roof <br /> 6 <br />
The URL can be used to link to this page
Your browser does not support the video tag.