5-85 HAWAII COUNTY CODE <br />(14) A new subsection C403.2.4.2.4 is added to the International Energy <br />Conservation Code to read as follows: <br />"C403.2.4.2.4 Door switches. Opaque and glass doors <br />opening to the outdoors in hotel and motel sleeping units, <br />guest suites, and time-share condominiums, shall be <br />provided with controls that disable the mechanical cooling or <br />reset the cooling setpoint to 90° F or greater within five <br />minutes of the door opening. Mechanical cooling may remain <br />enabled if the outdoor air temperature is below the space <br />temperature." <br />(15) Subsection C405.2 of the International Energy Conservation Code is <br />amended to read as follows: <br />"C405.2 Lighting controls (Mandatory). Lighting <br />systems shall be provided with controls as specified in <br />Sections C405.2.1, C405.2.2, C405.2.3, C405.2.4 and <br />C405.2.5. <br />Exceptions: Lighting controls are not required for the <br />following: <br />1. Areas designated as security or emergency areas that are <br />required to be continuously lighted. <br />2. Interior exit stairways, interior exit ramps and exit <br />passageways. <br />3. Emergency egress lighting that is normally off. <br />4. Spaces where the designed lighting power densities are <br />less than 70% of the lighting power densities specified in <br />Table C405.4.2(1) and Table C405.4.2(2)." <br />(16) Subsection C405.2.4 of the International Energy Conservation Code is <br />amended to read as follows: <br />"C405.2.4 Specific application controls. Specific <br />application controls shall be provided for the following: <br />1. Display and accent light shall be controlled by a <br />dedicated control that is independent of the controls <br />for other lighting within the room or space. <br />2. Lighting in cases used for display case purposes shall <br />be controlled by a dedicated control that is <br />independent of the controls for other lighting within <br />the room or space. <br />3. Hotel and motel sleeping units, guest suites, and <br />time-share condominiums shall have a master <br />control device that is capable of automatically <br />SUPP. 8 (7-2020) 5-116 <br />
The URL can be used to link to this page
Your browser does not support the video tag.