§ 5E-2-1 H AWAI‘I C OUNTY C ODE <br />Fuel type: same as proposed design.As proposed <br /> <br />Efficiencies: As proposed <br />Electric: Air-source heat pump with <br />prevailing federal minimum standards. <br />Nonelectric furnaces: natural gas furnace As proposed <br />d, e <br />Heating systems <br />with prevailing federal minimum <br />standards. <br /> <br />Nonelectric boilers: natural gas boiler with As proposed <br />prevailing federal minimum standards. <br /> <br />Capacity: sized in accordance with Section As proposed <br />R403.7. <br />Fuel type: Electric <br />Efficiency: in accordance with prevailing <br />As proposed <br />d, f <br />Cooling systems <br />federal minimum standards. <br /> <br />Capacity: sized in accordance with Section <br />As proposed <br />R403.7. <br />Fuel type: same as proposed designAs proposed <br />Efficiency: in accordance with prevailing As proposed <br />Service water <br />federal minimum standards. <br />d, e, f, g <br /> <br />heating <br />Use: Same as proposed design gal/day = 30 + <br />(10 × N) <br />br <br />Duct insulation: From Section R403.2.1 <br /> <br />A thermal distribution system efficiency <br />(DSE) of 0.88 shall be applied to both the <br />As tested or as specified <br />heating and cooling system efficiencies for <br />Thermal distribution in Table R405.5.2(2) if not <br />all systems other than tested duct <br />systems tested. Duct insulation <br />systems. For tested duct systems, the <br />shall be as proposed. <br />leakage rate shall be 4 cfm (113.3 L/min) <br />22 <br />(9.29 m) of conditioned floor <br />per 100 ft <br />area at a pressure of differential of 0.1 <br />inches w.g. (25 Pa). <br />Type: Manual, cooling temperature <br />Same as standard <br />Thermostat setpoint = 75°F; <br />reference <br />Heating temperature setpoint = 72°F <br />2 <br />For SI: 1 square foot = 0.93 m, 1 British thermal unit = 1055 J, 1 pound per square <br />2 <br />, 1 gallon (US) = 3.785 L, °C = (°F-32)/1.8, 1 degree = 0.79 rad. <br />foot = 4.88 kg/m <br />a. Where required by the code official, testing shall be conducted by an approved <br />party. Hourly calculations as specified in the ASHRAE Handbook of <br />Fundamentals, or the equivalent shall be used to determine the energy loads <br />resulting from infiltration. <br />SUPP. 9 (1-2021) <br /> <br />5E-24 <br /> <br />