§ 5F-2-1 H AWAI‘I C OUNTY C ODE <br />(14) A new subsection 911.3 is added to the Uniform Plumbing Code to read as <br />follows: <br />“911.3 Single Stack System. When approved by the administrative <br />authority, a single-stack system based on engineered studies and tests <br />may be used in lieu of other related provisions in this code. Plans and <br />specifications of such systems shall be prepared and stamped by a <br />Hawaii licensed mechanical engineer.” <br />(15) Subsection 1101.11.1 of the Uniform Plumbing Code is amended to read as <br />follows: <br />“1101.11.1 Primary Roof Drainage. Roof areas of a building shall <br />be drained by roof drains or gutters. The location and sizing of drains <br />and gutters shall be coordinated with the structural design and pitch <br />of the roof. Unless otherwise required by the authority having <br />jurisdiction, roof drains, gutters, vertical conductors or leaders, and <br />horizontal storm drains for primary drainage shall be sized based on a <br />storm of 60 minutes duration and 100 year return period. Refer to the <br />National Weather Service rainfall map for 100 year, 60 minute storms <br />at various locations.” <br />(16) Subsection 1211.5 of the Uniform Plumbing Code is amended by adding a <br />third sentence to read as follows: <br />“Ground-joint unions may only be used at exposed fixture, appliance, <br />or equipment connections and in exposed exterior locations <br />immediately on the discharge side of a building shutoff valve. Heavy <br />duty flanged type unions may be used in special cases, when first <br />approved by the administrative authority. Bushings shall not be used <br />in concealed locations.” <br />(17) A new subsection 1212.2 is added to the Uniform Plumbing Code to read as <br />follows: <br />“1212.2 Anchored or strapped. Liquified Petroleum Gas Cylinder <br />Tank Facilities more than 24 inches in vertical height, shall be <br />secured against seismic movements within upper top-third (1/3) of its <br />vertical dimensions.” <br />SUPP. 11 (1-2022) <br /> <br />5F-8 <br /> <br />
The URL can be used to link to this page
Your browser does not support the video tag.