E XISTING B UILDING C ODE §5C-2-1 <br />When wood-frame dwellings are supported by posts, 2-inch by 4-inch <br />(51 mm by 102 mm) foundation bracing must be provided. <br />For one-story conventional residential structures, the local practice of <br />using foundation blocks with termite shields is acceptable in all areas <br />except in flood hazard areas and for developments adjacent to <br />drainage facilities as specified in chapter 27, Hawai‘i County Code. <br />405.2.1.3 Boards for single-wall construction. <br />405.2.1.3.1 One and one-eighth inch boards. Single-wall <br />construction with boards of 1-1/8 inch (28.6 mm) net thickness are not <br />required to have girts. <br />405.2.1.3.2 One-inch boards. Where single-wall construction is with <br />boards of one-inch thickness (25.4 mm), no girt is required, provided <br />approved stiffeners for any section of such wall are spaced not more <br />than 10 feet (3048 mm) along the wall. <br />405.2.1.3.3 Three-fourths-inch boards. Single-wall construction <br />with boards of 3/4-inch (19.1 mm) net thickness must have girts and <br />cross partitions at least every 30 feet (9144 mm). <br />405.2.1.3.4 Approved stiffeners. Approved stiffeners must be studs <br />at least 2-inches by 4-inches (51 mm by 102 mm), full height window <br />or door jambs, posts, walls or partitions at right angles to the section <br />of wall under construction. <br />405.2.1.3.5 Girts. Girts for single-wall construction must be not less <br />than 2-inches by 6-inches (51 mm by 152 mm) belt course or other <br />approved strengthening about mid height between the floor and <br />ceiling on all exterior walls. <br />405.2.1.3.6 Complete load path. Blocking, bridging, straps, <br />approved framing anchors or mechanical fasteners must be designed <br />and installed to provide continuous ties from the roof to the foundation <br />system. Sheet metal clamps, ties or clips, must be formed of ASTM <br />A153 G90 galvanized steel or other approved corrosion-resistant <br />material of not less than 0.040-inch (1.01 mm) nominal thickness. <br />Uplift resistance must be in accordance with Table R802.11.” <br />SUPP. 11 (1-2022) <br />5C-7 <br /> <br />
The URL can be used to link to this page
Your browser does not support the video tag.