My WebLink
|
Help
|
About
|
Sign Out
Home
Chapter 05B Residential Building Code
PublicDocuments
>
County Clerk - Council
>
County Clerk
>
County Code
>
Chapter 05B Residential Building Code
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/27/2024 3:46:27 PM
Creation date
10/22/2021 3:46:49 PM
Metadata
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
54
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
§ 5B-2-1 H AWAI‘I C OUNTY C ODE <br />(10) Subsection R301.2.1.1, “Wind limitations and wind design required,” of the <br />International Residential Code is amended to read as follows: <br />“R301.2.1.1 Wind limitations and wind design required. The <br />wind provisions of this code shall not apply to the design of buildings <br />where wind design is required in accordance with Subsection <br />R301.2.1. <br />Exceptions: <br />1. For concrete construction, the wind provisions of this code <br />shall apply in accordance with the limitations of Sections <br />R404 and R608. <br />2. For structural insulated panels, the wind provisions of this <br />code shall apply in accordance with the limitations of Section <br />R610. <br />3. For cold-formed steel light-frame construction, the wind <br />provisions of this code shall apply in accordance with the <br />limitations of Sections R505, R603 and R804. <br /> In regions where wind design is required in accordance with <br />Subsection R301.2.1, the design of buildings for wind loads shall be in <br />accordance with one or more of the following methods: <br />1. AWC Wood Frame Construction Manual (WFCM) 2018. <br />2. ICC Standard for Residential Construction in High-Wind <br />Regions (ICC 600-14). <br />3. AISI Standard for Cold-Formed Steel Framing—Prescriptive <br />Method for One- and Two-Family Dwellings (AISI S230- <br />2015). <br />4. The Building Code, Chapter 5A, Hawai‘i County Code. <br /> The elements of design not addressed by the methods in Items 1 <br />through 4 shall be in accordance with the provisions of this code. <br /> Where wind design is required and design is in accordance with the <br />methods in Items 1 through 3, the building must be provided with <br />opening protection for windborne debris. Options for opening <br />protection or alternatives to opening protection shall be in accordance <br />with the Building Code, Chapter 5A, Hawai‘i County Code.” <br />SUPP. 11 (1-2022) <br /> <br />5B-10 <br /> <br />
The URL can be used to link to this page
Your browser does not support the video tag.