My WebLink
|
Help
|
About
|
Sign Out
Home
Continuous Lanai Portal Frame Drawing Samples_arrangement 34x22
PublicDocuments
>
Public Works
>
Building Division
>
Bulletins
>
Continuous Lanai Portal Frame Drawing Samples_arrangement 34x22
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/3/2021 3:45:05 PM
Creation date
11/10/2021 2:52:15 PM
Metadata
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
3
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
POST -END DETAIL <br />POST -FRAME DETAIL <br />SEE SHEET 12 <br />1'-4" <br />SEE SHEET 8 <br />3/8", MIN. PLYWD SHEATHING <br />MIN. <br />FASTENED W/ 8D COMMON OR GALV. <br />BOX NAILS @ 3" O.C., IN ALL <br />FRAMING <br />(STUDS, BLOCKING, & SILLS) <br />TYP. <br />�� <br />16'-0", MAX. 20'-0", MAX. <br />LATE <br />PLATE- <br />�SILL <br />5 OO OO <br />--I <br />5 <br />ARRANGEMENT 1 ARRANGEMENT 2 <br />5i <br />F <br />EDGED OF CONCRETE <br />0 <br />w <br />m <br />HEADER BEAM, ABOVE <br />o <br />L` <br />32'-0", MAX. 32'-0", MAX. <br />ARRANGEMENT 3 ARRANGEMENT 4 <br />NON—PANEL CORNER PANEL CORNER <br />A <br />I PORTAL FRAME - CORNER DETAIL WHERE PATIO EXTENDS BEYOND 8'-0" FROM MAIN DWELLING <br />EDGE OF CONCRETE <br />MIN. 1,000 LB METAL STRAP, <br />FROM <br />HEADER TO SUPPORTING 4x4 <br />POST m J <br />40'-0", MAX. <br />(LSTA24 Or APPROVED EQ) <br />� <br />ARRANGEMENT 5 <br />Qo <br />2x4 STUD FRAMING, TYP <br />im z <br />3/8", MIN. <br />� <br />o w <br />PLYWD SHEATHING <br />w <br />_ `L' EXTERIOR <br />WALL FACE <br />48'-0", MAX. <br />SILL PLATE <br />4x4 POST <br />ARRANGEMENT 6 <br />MIN. 1,000 LB HOLD—DOWN DEVICE <br />(DTT1Z Or APPROVED EQ) <br />64'-0", MAX. <br />B <br />PORTAL FRAME TO MAIN DWELLING WHERE PATIO EXTENDS BEYOND 8'-0" FROM MAIN DWELLING <br />ARRANGEMENT 7 <br />PRO,ECTTTLE PRESCRIPTIVE SOLUTIONS UTILIZING <br />PRO,ECTTTLE: PRESCRIPTIVE SOLUTIONS UTILIZING <br />ALTERNATE BRACED WALL PANELS <br />ALTERNATE BRACED WALL PANELS <br />-- <br />-< -- <br />10/2021 <br />10/2021 <br />REV <br />DESCRIPTION <br />DATE <br />REV <br />DESCRIPTION <br />DATE <br />EETTn : <br />EETTn : <br />COUNTY OF HAWAII <br />COUNTY OF HAWAII <br />DESIGN BY: DHL <br />s"'"° <br />DESIGN BY: DHL <br />11T 11. <br />DEPARTMENT OF PUBLIC WORKS <br />WALL FRAME PLAN <br />1 S <br />DEPARTMENT OF PUBLIC WORKS <br />SUMMARY OF ARRANGEMENTS <br />1 6 <br />BUILDING DIVISION <br />DRAWN BY: NB <br />BUILDING DIVISION <br />DRAWN BY: NB <br />101 PAUAHI ST; SUITE 7 <br />101 PAUAHI ST; SUITE 7 <br />HILO, HI 96720 <br />CHECKED BYflHL <br />- OF - SHTS <br />HILO, HI 96720 <br />CHECKED BYflHL <br />- OF - SHTS <br />GENERAL <br />NOTES <br />ARRANGEMENTS METHOD NOTES <br />THE FOLLOWING ALTERNATE BRACED WALL PANEL <br />1. ABSOLUTELY NO SPLICING OF THE HEADER BEAM IS <br />ARRANGEMENTS ARE INTENDED <br />FOR USE ALONG A <br />ALLOWED OTHER THAN WHAT IS SHOWN IN THE <br />PATIO/GARAGE EXTERIOR WALL <br />LINE. EACH ARRANGEMENT IS <br />ARRANGEMENTS. <br />ASSUMED TO BE USED ACROSS <br />THE ENTIRE LENGTH OF THE <br />WALL LINE. THEREFORE, GIVEN <br />A BRACED WALL LINE <br />2. ALL ARRANGEMENTS APPLY TO SINGLE -STORY, <br />LENGTH, THE APPROPRIATE ARRANGEMENT <br />CAN BE SELECTED <br />SLAB -ON -GRADE STRUCTURES ONLY. <br />FROM THE SCHEDULE BELOW. <br />3. A HEADER IS SUPPORTED BY EITHER A "PANEL" OR A <br />"VERTICAL SUPPORT". ALL PANELS ARE A MINIMUM OF <br />16" WIDE, WHILE A VERTICAL SUPPORT IS A MINIMUM OF <br />6" OR 12" WIDE DEPENDING UPON WHETHER THE HEADER <br />OCCURS ON ONE SIDE OR BOTH SIDES OF THE SUPPORT. <br />4. IT IS ASSUMED FOR ALL ARRANGEMENTS (EXCEPT <br />ARRANGEMENT 4) THAT THE HEADER SUPPORTS (i.e., <br />PANELS AND VERTICAL SUPPORTS) ARE EQUALLY SPACED <br />ARRANGEMENTS <br />SCHEDULE <br />APART. <br />5. THE RELEVANT DETAILS IN THIS PACKET SHALL BE <br />ARRANGEMENT # <br />BRACED <br />WALL LINE LENGTH <br />PHOTOCOPIED AND/OR INCORPORATED INTO FULL-SIZED <br />1 <br />16' MAX <br />2 <br />20' MA' 0MAX <br />RESIDENTIAL PLANS. MERELY ATTACHING 8-1/2" x 11„ <br />- <br />HARDCOPIES OF THESE DETAILS WILL NOT BE ACCEPTED. <br />3 <br />32'' MAX <br />------------------------------- <br />4 <br />--------------------------------------------------------------------------------------- <br />32' MAX <br />------------------------------- <br />5 <br />--------------------------------------------------------------------------------------- <br />40' MAX <br />------------------------------- <br />6 <br />--------------------------------------------------------------------------------------- <br />48' MAX <br />7 <br />64' MAX <br />COUNTY OF HAWAII <br />DEPARTMENT OF PUBLIC WORKS, BUILDING DIVISION <br />PRESCRIPTIVE SOLUTIONS UTILIZING <br />ALTERNATE BRACED WALL PANELS <br />SUMMARY OF ARRANGEMENT & <br />WALL FRAME PLAN <br />DATE: 10/2021 <br />DRAWN BY: NB <br />CHECKED BY: DHL <br />SHEET NO. <br />3 <br />OF # SHTS <br />
The URL can be used to link to this page
Your browser does not support the video tag.