My WebLink
|
Help
|
About
|
Sign Out
Home
PD Background Report (PL-SMA-2022-000023)
PublicDocuments
>
Planning Department
>
Leeward/Windward Planning Commission
>
Board Packets
>
2023
>
2023-01-06 Windward
>
Item #3 Douglas Kerr (PL-SMA-2022-000023)
>
PD Background Report (PL-SMA-2022-000023)
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/29/2022 9:32:25 AM
Creation date
12/29/2022 9:29:17 AM
Metadata
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
102
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
land. The new single utility pole would be placed into a hole that is 2 feet in diameter and 5 feet <br /> deep and would be located in a previously disturbed area near the property boundary, thereby <br /> minimizing mount of clearing required and potential impact on the land. Additionally, roof <br /> mounted photovoltaic panels as well as a battery storage system are also planned with the home to <br /> help reduce the overall energy requirements of the home and the impact upon power requirements <br /> for HELCO. <br /> The domestic water supply would be provided from an onsite water well located along the <br /> far northwest side of the subject property, about 18 feet makai of the Paradise Ala Kai Drive. It <br /> will have a pump capable of delivering up to 30 gallons per minute. The water well and pump will <br /> be connected to the residence through standard means. The State of Hawaii, Department of Land <br /> and Natural Resources has provided a State Historic Preservation Division letter making a <br /> determination that no historic properties affected for the work described in the well permit <br /> application and allowed the permit issuance to proceed. (See Exhibit Q, State of Hawaii letter.) <br /> Wastewater would be treated by an individual septic system located adjacent to the <br /> residence, which would be designed and installed in conformance with requirements of the State <br /> Department of Health. The septic system would have a tank capacity of 1000 gallon and an <br /> absorption field that extends over an area of approximately 216 square feet. The trenching <br /> requirements for the septic system are summarized for the project in Exhibit R, Site Plan for Septic <br /> System. (Note that the drawn private well and home structure are not indicative of the actual well <br /> or home location,which is accurate in ExhibitH,Blended Site Map. Essentially,the only important <br /> image, and the only area the septic contractor has control over, on the Septic Site Plan is the <br /> location of the septic system in reference to the proposed house.) <br /> P. Any areas of critical concerns have been assessed by the Director. <br /> No critical areas of concern were noted by the Director when the proposed project was <br /> reviewed for Special Management Assessment. The following two notes about SMA <br /> determination were listed in the Planning Director's letter. Based on information contained in the <br /> Building Permit application, the property has a valuation in excess of$500,000. Second, it was <br /> noted that the setback needed to be 40-foot from the certified shoreline setback. <br /> This Application for a Major SMA remedies the first concern. The proposed residence has <br /> been moved back 40 feet from the shoreline area. This remedies the second concern. <br /> II. Anticipated impact upon the Special Management including but not limited to the <br /> following: <br /> A. Description of environmental setting; <br /> The subject property is on a vacant overgrown wooded lot of 0.49 acres, or 21,344 square <br /> feet in HPP. The only environmental setting that distinguishes this vacant lot from the thousands <br /> of vacant lots in HPP is that it sits on the shoreline. Of course, this is an important distinction that <br /> deserves special care because the shoreline requires protections that inland areas do not. Certainly, <br /> this shoreline is not quite as environmentally sensitive as a common sand shoreline because the <br /> Page 1 13 <br /> Attachment to SMA Major Use Permit Application of Kerr/Gleason,TMK: (3) 1-S-OS8 : OS3 <br /> 13 <br />
The URL can be used to link to this page
Your browser does not support the video tag.