My WebLink
|
Help
|
About
|
Sign Out
Home
2024-06-28 PL-INT-2024-008107 Oceanit Category PL.5
PublicDocuments
>
Finance Department
>
Purchasing Division
>
Professional Services Information
>
SOQs- Approved Professional Service Providers
>
FY 24-25
>
PL - PLANNING
>
PL.05 - Environmental- EA, EIS
>
2024-06-28 PL-INT-2024-008107 Oceanit Category PL.5
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/2/2024 1:15:07 PM
Creation date
7/10/2024 3:10:04 PM
Metadata
Fields
Template:
Plan Doc Template
Document Date
6/28/2024
Permit Number
PL-INT-2024-008107
Description
Oceanit, Professional services for category PL.3, PL.4, PL.5, PL.9
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
71
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
E. RESUMES OF KEY PERSONNEL PROPOSED FOR THIS CONTRACT <br /> (Complete one Section E for each key person.) (2'Z-= z <br /> 12.NAME 13.ROLE IN THIS CONTRACT 14.YEARS EXPERIENCE <br /> Ken Cheung, Ph.D., P.E. Director a.TOTAL b.WITH CURRENT FIRM <br /> 33 27 <br /> 15.FIRM NAME AND LOCATION(City and State) <br /> Ocean it Laboratories, Inc, Honolulu, Hawai'i <br /> 16.EDUCATION(Degree and Specialization) 17.CURRENT PROFESSIONAL REGISTRATION(State and Discipline) <br /> Doctor of Philosophy/Aerospace Engineering/University of Hawai'i/Professional Engineer/2000/PE-10020 <br /> Notre Dame/1997 US DOT Bridge Inspector/ 1997 <br /> Master of Science/Mechanical Engineering/University of Notre HAZWOPER; SCUBA <br /> Dame/1993 <br /> Bachelor of Science/Aerospace Engineering/University of <br /> Notre Dame/1991 <br /> 18.OTHER PROFESSIONAL QUALIFICATIONS(Publications,Organizations,Training,Awards,etc.) <br /> Dr. Cheung is Oceanit's lead Cathodic Protection Engineer. Fully NACE Certified, he leads the design and development teams for <br /> Cathodic Protection projects. <br /> 19. RELEVANT PROJECTS <br /> (1)TITLE AND LOCATION(City and State) (2)YEAR COMPLETED <br /> Investigation &Conceptual Remedial Design Fuel Pipeline Leak, Victor 1 PROFESSIONAL SERVICES CONSTRUCTION(If applicable) <br /> Dock, Fleet& Industrial Supply Center, Pearl City Peninsula, O'ahu, 1998 1998 <br /> Hawai'i <br /> (3)BRIEF DESCRIPTION(Brief scope,size,cost,etc.)AND SPECIFIC ROLE 0 Check if project performed with current firm <br /> a. Project Scientist: Investigate and assess the extent of subsurface jet fuel contamination in the vicinity of Victor-1 <br /> Dock in Pearl Harbor as part of the Comprehensive Long-Term Environmental Action Navy II (CLEAN II) program <br /> by the Fleet and Industrial Supply Center(FISC) Pearl Harbor.The project had two objectives: 1. Delineate the <br /> extent of JP-8 contamination in soil and groundwater and develop a conceptual remedial design. <br /> (1)TITLE AND LOCATION(City and State) (2)YEAR COMPLETED <br /> Coastal Engineering Studies for Brennecke Beach Coastal Revetments PROFESSIONAL SERVICES CONSTRUCTION(If applicable) <br /> 2000 2000 <br /> (3)BRIEF DESCRIPTION(Brief scope,size,cost,etc.)AND SPECIFIC ROLE 0 Check if project performed with current firm <br /> b. Project Scientist: Oceanit performed coastal engineering studies to design and protection scheme for Hoone <br /> Road in preparation for the removal of a seawall, for$83K. Coastal engineering field measurements were <br /> performed, including offshore bathymetric measurements,water quality sampling and analysis, sand grain size <br /> and distribution analysis, and current/wave studies. Environmental documentation was also prepared. <br /> (1)TITLE AND LOCATION(City and State) (2)YEAR COMPLETED <br /> Farrington Highway Waterline Cathodic Protection PROFESSIONAL SERVICES CONSTRUCTION(If applicable) <br /> 2003 2003 <br /> (3)BRIEF DESCRIPTION(Brief scope,size,cost,etc.)AND SPECIFIC ROLE 0 Check if project performed with current firm <br /> c. Project Scientist: Oceanit engineered a design for a Cathodic Protection (CP) system for approximately 7,315 feet <br /> of 24" dia. ductile iron transmission water line for the Board of Water Supply.The CP design incorporated a <br /> remote monitoring system for pipeline maintenance. Project cost$210K. <br /> (1)TITLE AND LOCATION(City and State) (2)YEAR COMPLETED <br /> Cathodic Protection for Vancouver Drive and Vancouver Place 20" and PROFESSIONAL SERVICES CONSTRUCTION(If applicable) <br /> 8"water mains, Honolulu, O'ahu, Hawai'i 1999 <br /> d. (3)BRIEF DESCRIPTION(Brief scope,size,cost,etc.)AND SPECIFIC ROLE 0 Check if project performed with current firm <br /> Project Scientist: Oceanit engineered a design for a Cathodic Protection (CP) system for ductile iron transmission <br /> water line.The CP design incorporated a remote monitoring system for pipeline maintenance. Project cost$13K. <br /> (1)TITLE AND LOCATION(City and State) (2)YEAR COMPLETED <br /> Cathodic Protection of Underground Water Lines at Kolea Cove Offsite PROFESSIONAL SERVICES CONSTRUCTION(If applicable) <br /> Water Access Road, Waipahu, O'ahu, Hawai'i 1999 <br /> (3)BRIEF DESCRIPTION(Brief scope,size,cost,etc.)AND SPECIFIC ROLE 0 Check if project performed with current firm <br /> e. Construction Cost: $50,000 Work included research and review of available geologic and soils information; <br /> performance of field resistivity testing and conducting analysis of field and laboratory data; preparation of a <br /> formal report summarizing the work,findings and geotechnical engineering recommendations. Oceanit designed <br /> a cathodic protection (CP)system for a ductile iron water line, including all appurtenances. <br /> STANDARD FORM 330 ( REV. 7/2021) PAGE 1 <br />
The URL can be used to link to this page
Your browser does not support the video tag.