Laserfiche WebLink
12/18124,8:41 AM about:blank <br /> WALL LINE ELEVATIONP VIEW 1 ��w <br /> 11 <br /> 1, ,,l <br /> Bi B2 B3 <br /> I <br /> Total wall Line Length: 20' 0" I <br /> WALL LINE PLAN VIEW <br /> Bi B2 B3 <br /> Story Wall Bracing Wind Wind Bracing Seismic Seismic Bracing Required Qualified Bracing <br /> Line Method Factors Amount Factors Amount Bracing Bracing Status <br /> 1st Story 2 PF-H 1.29 7.16 1.05 11.55 11.55 12 Compliant <br /> Furthest Distance to Adjacent BWL 12' 0" Stone or Masonry Veneer Omitted <br /> Roof Ease to Ridge Height 5 feet Wall Dead Load > 8 psf but C= 15 psf <br /> Wall Line Length 20' 0" Roof/Ceiling Dead Loads 20 psf <br /> Gypsum Included <br /> Blocking Included <br /> Adjacent <br /> Wall Line Wall Story Bracing Segment opening Qualified Nails Tension Hold Down <br /> Segment Height Height Method Length Height Segment Tie <br /> B1 8' 9' PF-H 2' 0" 7' 0" 4 3"/3" grid DR 3,500 <br /> B2 8' 9' PF-H 2' 0" 7' 0" 4 3"/3" grid DR 3,500 <br /> B3 8' 9' PF-H 2' 0" 7' 0" 4 3"/3" grid DR 3,500 <br /> Include proper PF or ABW details on the plans. If a PF-HD is used, and a second PF-HD is not included on the <br /> other side of an opening, the side with no PF-HD needs to show the detail for a min. 1,000lb HD to restrain the <br /> post on that side. <br /> ;-:Wank DOCUMENT 2 - PG 10 OF 15 „O <br />