Laserfiche WebLink
1 11 24,8:41 1 :blank <br /> WALL LINE ELEVATION VIE, `,I l I32 ,4—O 15 II 2 <br /> t� <br /> o <br /> oi <br /> " f <br /> Bi B2 <br /> ITotal WadWpt Length: 20' 0" <br /> WALL LINE PLAN VIEW <br /> B1 B2 <br /> Story Wall Bracing Wind Wind Bracing Seismic Seismic Bracing Required Qualified Bracing. <br /> Line Method Factors Amount Factors Amount Bracing Bracing Status <br /> 2nd Story 1 PF-H 1.05 3.04 1.05 5.25 5.25 8 Compliant <br /> Furthest Distance to Adjacent BWL 12' 0" Stone or Masonry Veneer Omitted <br /> Roof Ease to Ridge Height 5 feet Wall Dead Load > 8 psf but <= 15 psf <br /> Wall Line Length 20' 0" Roof/Ceiling Dead Loads 20 psf <br /> Gypsum Included <br /> Blocking Included <br /> Adjacent <br /> Wail Line Wall Story Bracing Segment Opening Qualified Nails Tension Hold Down <br /> Segment Height Height Method Length Height Segment Tie <br /> Bl 9' 10' PF-H 2' 0" 8' 0" 4 3"/3" grid DR 3,500 <br /> B2 9' 10' PF-H 2' 0" 8' 0" 4 3"/3" grid DR 3,500 <br /> Include proper PF or ABW details on the plans. If a PF-HD is used, and a second PF-HD is not included on the <br /> other side of an opening, the side with no PF-HD needs to show the detail for a min. 1,000lb HD to restrain the <br /> post on that side. <br /> ;.._blank DOCUMENT 2 - PG 13 OF 15 Bilo <br />