My WebLink
|
Help
|
About
|
Sign Out
Home
Ordinance 07-084
PublicDocuments
>
County Clerk - Council
>
County Clerk
>
County Code
>
Ordinances
>
Ordinance 07-084
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/30/2011 12:10:16 PM
Creation date
8/30/2011 12:08:12 PM
Metadata
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
45
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
(18) Deleting Sections 413.0 through 413.7. <br />Sections 413.0 through 413.7 are deleted. Table 4 -1 may be used <br />as a guide only. See Department of Health Chapter 11, Sanitation, <br />paragraph 11 -11 -9 Minimum sanitary facilities for assembly, <br />school, dorms, restaurant and liquor dispenser type occupancies. <br />See State Department of Labor and Industrial Relations, Division <br />of Occupational Safety and Health, Chapter 67 Sanitation, <br />paragraph 12 -76 -4, Toilet facilities and lavatories for the required <br />toilet facilities for employees. (See also UBC amendments Section <br />303.5 which requires Group A Occupancy (assembly) area to have <br />two female water closets for every male water closet.) <br />(19) Amending Section 420.0. Section 420.0 is amended by adding: <br />"EXCEPTION: Tub - mounted hand -held shower heads do not <br />require an anti -scald valve." <br />(20) Amending Section 501.0. Section 501.0 is amended by adding a second paragraph to <br />read: <br />"Provisions in NFPA (National Fire Protection Association) <br />Standard No. 211 -1996, Chimneys, Fireplaces, Vents and Solid <br />Fuel Burning Appliances, and Part 7, Venting of Equipment, in the <br />National Fuel Gas Code, NFPA 54 -1996, may be used in lieu of <br />provisions in this chapter covering the same subject and as <br />guidelines for design, construction and workmanship." <br />(21) Adding Section 505.4. Section 505.4 is added to read: <br />'`505.4. A vacuum relief valve, dip tube with perforated inlet or an <br />approved method shall be provided to prevent siphoning in any <br />water heater tank or hot water boiler tank." <br />(22) Adding Section 506.3. Section 506.3 is added to read: <br />"506.3. A vacuum relief valve, dip tube with perforated inlet or an <br />approved method shall be provided to prevent siphoning in any <br />water heater tank or hot water boiler tank." <br />(23) Amending Section 507.3.1. Section 507.3.1 is amended by adding to the end thereof: <br />"The upper combustion air duct shall extend horizontally or <br />upwards to the outside of the enclosure." <br />17 <br />
The URL can be used to link to this page
Your browser does not support the video tag.