(29) Amending Section 511.4. Section 511.4 is amended by deleting the second and third <br />sentences. <br />(30) Adding Sections 512.9 and 512.10. Sections 512.9 and 512.10 are added to read: <br />"512.9. Listed gas fired water heaters need not be provided with a vent to the <br />exterior when installed in an open parking garage or carport under the <br />following conditions: <br />(1) Such a garage shall comply with the openings provisions of the <br />Building Code for open parking garages or carports. <br />(2) Floor mounted heaters shall be installed in the garage so that <br />the bottom of the combustion chamber is at least eighteen (18) <br />inches above the floor and outside grade level. <br />(3) Heaters shall be protected against mechanical damage as <br />provided in Section 510.3. <br />(4) An acceptable vent cap shall be provided unless not required <br />by the heater's listing or the manufacturer's instructions. <br />(5) When location of the heater may result in unsatisfactory <br />dispersions of combustion products, venting by means of a <br />mechanical draft system to the exterior wall line or to other <br />approved point of termination shall be provided. <br />(6) Installation of heaters under these provisions shall be approved <br />by the administrative authority and the serving gas supplier. <br />512.10. Listed single and two- family gas fired water heaters rated <br />at less than 55,000 Btuhs need not be provided with a vent <br />extended through the roof of the building or enclosure when <br />installed outside of the exterior walls of the building unenclosed or <br />in approved enclosures. Protection of such water heaters from the <br />weather shall be provided either by the appliance design itself or <br />by an approved enclosure, when climatic or safety conditions <br />warrant. In addition, such installations shall meet the following: <br />(1) Adequate openings and clearances shall be provided by the <br />enclosure in accordance with Sections 507 and 508. <br />(2) Enclosure openings or vent caps shall be located in accordance <br />with Section 517.5. <br />19 <br />
The URL can be used to link to this page
Your browser does not support the video tag.