My WebLink
|
Help
|
About
|
Sign Out
Home
PV Electrical Review Bulleten 060817
PublicDocuments
>
Public Works
>
Building Division
>
PV Electrical Review Bulleten 060817
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/9/2017 10:31:25 AM
Creation date
6/9/2017 10:31:24 AM
Metadata
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
3
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
(2) Rated maximum power-point voltage <br />(3) Maximum system voltage <br />(4) Short-circuit current <br />(5) Maximum rated output current of the charge controller (if installed) <br />9) Interactive System Point of Interconnection. All interactive system(s) points of <br />interconnection with other sources shall be marked at an accessible location at the <br />disconnecting means as a power source and with the rated ac output current and the <br />nominal operating voltage. – NEC 690.54 <br />10) Photovoltaic Power Systems Employing Energy Storage. Photovoltaic power <br />systems employing energy storage shall also be marked with the maximum operating <br />voltage, including any equalization voltage and the polarity of the grounded circuit <br />conductor. – NEC 690.55 <br />11) Identification of Power Sources – NEC 690.56 <br />i) Facilities with Stand-Alone Systems – NEC 690.56(A). Any structure or building <br />with a photovoltaic power system that is not connected to a utility service source and <br />is a stand-alone systems shall have a permanent plaque or directory installed on the <br />exterior of the building or structure at a readily visible location of the building or <br />structure at a readily visible location acceptable to the authority having jurisdiction. <br />The plaque or directory shall indicate the location of system disconnecting means <br />and that the structure contains a stand-alone electrical power system. <br />ii) Facilities with Utility Services and PV Systems – NEC 690.56(B). Buildings or <br />structures with both utility service and a photovoltaic system shall have a permanent <br />plaque or directory providing the location of the service disconnecting means and the <br />photovoltaic system disconnecting means if not located at the same location. <br />12) Inverter Output Connection – NEC 690.64(7) <br />WARNING <br />INVERTER OUTPUT CONNECTION <br />DO NOT RELOCATE <br />THIS OVERCURRENT DEVICE <br />C) Backfed Circuit Breakers <br />1) Suitable for backfeed. Circuit breakers, if backfed, shall be suitable for such operation. <br />– NEC 690-64(B)(5) <br />D) Equipment Locations <br />1) The location of all PV equipment shall be located in plan view, any roof mounted <br />equipment shall be indicated as such. <br />E) Equipment Specification Sheets <br />1) Provide all PV equipment specification sheets for verification of calculations. <br /> <br />Brandon Pearsall <br />Electrical Engineer, PE <br />brandon.pearsall@hawaiicounty.gov <br />Issued by: David Yamamoto, Building Division Chief <br />County of Hawai`i is an Equal Opportunity Provider and Employer. <br />
The URL can be used to link to this page
Your browser does not support the video tag.