2007 SUPPLEMENT TO THE IRC <br />1. Nominal 1 -inch -by -4 -inch (19.1 mm by 88.9 mm) continuous diagonal braces let in to the top and bottom <br />plates and the intervening studs or approved metal strap devices installed in accordance with the <br />manufacturer's specifications. The let -in bracing shall be placed at an angle not more than 60 degrees <br />(1.06 rad) or Tess than 45 degrees (0.79 rad) from the horizontal. <br />2, Wood boards of 5/8 -inch (15.9 mm) net minimum thickness applied diagonally on studs spaced a maximum <br />of 24 inches (610 mm). Diagonal boards shall be attached to studs in accordance with Table R602.3(1). <br />3. Wood structural panel sheathing with a thickness not less than 3/8 inch (9.5 mm) for 16 -inch (406 mm) or <br />24 -inch (610 mm) stud spacing. Wood Structural panels shall be installed in accordance with Table <br />R602.3(3) and Table R602.3(1), <br />4, One -half-inch (12.7 mm) or 25/32 -inch (19.8 mm) thick structural fiberboard sheathing applied vertically or <br />horizontally on studs spaced a maximum of 16 inches (406 mm) on center. Structural fiberboard sheathing <br />shall be installed in accordance with Table R602.3(1). <br />5. Gypsum board with minimum 1h -inch (12.7 mm) thickness placed on studs spaced a maximum of 24 inches <br />(610 mm) on center and fastened at panel edges including top and bottom plates at 7 inches (178 mm) on <br />center with the size nails specified in Table R602.3(1) for sheathing and Table R702.3.5 for interior gypsum <br />board. <br />6. Particleboard wall sheathing panels installed in accordance with Table R602.3(4) and Table R602.3(1). <br />7. Portland cement plaster on studs spaced a maximum of 16 inches (406 mm) on center and installed in <br />accordance with Section R703.6. <br />8. Hardboard panel siding when installed in accordance with Table R703.4. <br />Exception: Alternate braced wall panels constructed in accordance with Sections R602.10.3.2.1 or <br />R602.10.3.2.2 shall be permitted to replace any braced wall panel in any of the above methods of braced wall <br />panels. <br />R602.10.2.1 Braced wall panel interior finish material. Braced wall panels shall have gypsum wall board <br />installed on the side of the wall opposite the bracing material. Gypsum wall board shall be not less than 'h inch <br />(12.7 mm) in thickness and be fastened in accordance with Table R702.3.5 for interior gypsum wall board. <br />Exceptions: <br />1. Wall panels that are braced in accordance with Method 5. <br />2. Wall panels that are braced in accordance with Section R602.10.3.2 . <br />3. When an approved interior finish material with an in -plane shear resistance equivalent to gypsum board <br />is installed. <br />4. For Methods 2, 3, 4, 6, 7, and 8, gypsum wall board is permitted to be omitted provided the percentage <br />of bracing in Table R602.10.1(1) is multiplied by a factor of 1.5. <br />R602.10.2.2 Adhesive attachment of sheathing in Seismic Design Categories C, Do, D1 and D2. Adhesive <br />attachment of wall sheathing shall not be permitted in Seismic Design Categories C, Da, DI and D2. <br />R602.10.3 Minimum length of braced panels. For Methods 2, 3, 4, 6, 7 and 8 above, each braced wall panel <br />shall be at least 48 inches (1219 mm) in length, covering a minimum of three stud spaces where studs are spaced <br />16 inches (406 mm) on center and covering a minimum of two stud spaces where studs are spaced 24 inches <br />(610 mm) on center. For Method 5 above, each braced wall panel and shall be at least 96 inches (2438 mm) in <br />length where applied to one face of a braced wall panel and at least 48 inches (1219 mm) where applied to both <br />faces. For Methods 2, 3, 4, 6, 7 and 8, for purposes of computing the percentage of panel bracing required in <br />Table R602.10.1(1), the effective length of the braced wall panel shall be equal to the actual length of the panel. <br />When Method 5 panels are applied to only one face of a braced wall panel, bracing percentages required in Table <br />R602.10.1(1) for Method 5 shall be doubled. <br />Exceptions: <br />1. Lengths of braced wall panels for continuous wood structural panel sheathing shall be in accordance <br />with Section R602.10.4. <br />2. Lengths of alternate braced wall panels shall be in accordance with Section R602.10.3.2.1 or Section <br />R602.10.3.2.2. <br />3. For Methods 2, 3, 4, 6, 7 and 8 in Seismic Design Categories A, B, and C: Panels between 36 inches <br />and 48 inches in length shall be permitted to count towards the required percentage of bracing in Table <br />R602.10.1(1), and the effective contribution shall comply with Table R602.10.3. <br />IRC -44 <br />Copynghted it 2007 ICC (ALL RIGHTS RESERVED), licensed to Neil Erickson pursuant to License Agreement wim ICC No further reproductions authorized or dennbution authonzed <br />ANY UNAUTHROIZED REPRODUCTION OR DISTRIBUTION ISA VIOLATION OF THE FEDERAL COPYRIGHT ACT AND THE LICENSE AGREEMENT AND SUBJECT TO CIVIL AND CRIMINAL PENALTIES THEREUNDER <br />