Laserfiche WebLink
§ 27-18 HAWAII COUNTY CODE <br />(c) <br />(3) New construction, improvements to repetitive loss structures, and substantial <br />improvement shall be designed and constructed with electrical, heating, <br />ventilation, plumbing, air-conditioning equipment, and other service facilities <br />including, but not limited to, furnaces, heat pumps, water heaters, washers, <br />dryers, elevator lift equipment, electrical junction boxes, circuit breaker boxes, <br />and food freezers located above the base flood elevation plus any required <br />freeboard. <br />(4) Within Zones V and VE, new construction, improvements to repetitive loss <br />structures, and substantial improvements shall comply with the standards of <br />section 27-23. <br />(5) Recreational vehicles placed on sites within Zones AH and AE on the FIRM <br />shall be elevated and anchored or be on the site for less than one hundred <br />eighty consecutive days or be fully licensed and highway ready. <br />Encroachments. <br />(1) Within a floodway, encroachments (including fill), new construction, <br />improvements to repetitive loss structures, substantial improvements, and <br />other developments, shall be prohibited unless certified by a professional civil <br />engineer licensed in the State of Hawai`i, with supporting data, that the <br />encroachment will not cause any increase in base flood elevations during the <br />occurrence of the base flood discharge. <br />(2) Require, until a regulatory floodway is designated, that no new construction, <br />improvements to repetitive loss structures, substantial improvements, or other <br />development (including fill), shall be permitted within Zones AE on the FIRM, <br />unless demonstrated that the cumulative effect of the proposed development, <br />when combined with all other existing and anticipated development, will not <br />increase the water surface elevation of the base flood at any point. <br />(3) Within all zones of special flood hazards, but not including floodways, filling <br />which would result in the blockage or impediment of flow and/or induce or <br />aggravate flooding shall be prohibited unless certified by a professional civil <br />engineer licensed in the State of Hawai`i, with supporting data, that the <br />encroachment will not cause any increase in base flood elevations during the <br />occurrence of the base flood discharge. <br />(4) Within floodway fringe areas, filling to elevate the lowest floor of a <br />nonresidential structure may only be permitted where the structure: <br />(A) Is floodproof'ed so that below the base flood elevation plus any required <br />freeboard the structure is watertight with walls substantially <br />impermeable to the passage of water, and <br />(B) Has structural components capable of resisting hydrostatic and <br />hydrodynamic loads and the effects of buoyancy. <br />(5) In Zones V and VE, use of fill for structural support of buildings shall be <br />prohibited. <br />27-18 <br />