Loading...
HomeMy WebLinkAboutORD 1933-103._ ____ __ } 1,.. I ) ~ `' COUNTY OF HAWAII, TERRI- TORY OF HAWAII ORDINANCE NO. 103 An Ordinance to Be Known as the EUILDINC CODE Relating to the Erecting, Con- struction, Removal, Alteration or auy oilier impravetnen is and Re- pair} and Occupancy of Building and other Structures in the County of Hawaii; providing for a De- partment of Building; providing for a Building Inspector and Defin- ing his Powers and Duties; Provid- ing certain duties for the Firc Chief of Hilo; Providing for estab- :~shfng Zonin6' Districts in the Oity of Hiio and elsewhere in the County of Hawaii, relating to buildings and their use and oc- cupancy; Providing for the Is- suance of Permits and Fixing Fees Therefor, and for other Fees and Charges. and Providing Penalties for Violations of this Ordinance. Be It Ordained 6y the Board of Supervisors of the County of Ha- waii: CHAPTER 1 ADAIdNISTRATION Section 1.110. APPLICATION FOR PERMIT. Pefore proceeding with the construction, enlargement, alter- aL10n, OT ally other lIDproV elnents, ropair or removal of any bnild- tu3 or other structure, a Pet•- mit therefor shall be first obtained by the corner, or the lessee or agent of either, from the Building Inspec- tor. The application for such per- mit shall be made on a form which shall be furnished by the Building Inspector, on which the applicant shall state the site, the character, the proposed use, the names oP the owner, architect and builder, the es- timated time to complete, the di- ntenslcnc, the eshimated cost and the use proposed of the structure con- tcnrtlated, together with whatever additonal data may be deemed ne- cESary by the Building Inspector. Estimated Cost to be based on the _'^,en careent market value of labor an!t material. Provided, however, where such work is otttside the City Limit of the City of Hilo, that the provisions of this scrtlon shall not apply to fa) the restoration of plaster, papering, or painting and lbl to repair work rcC exceeding One Hundred Dollars i$100.C0) in cost, and which does rot involve the exterior or party walls, trusses, bearing columns. stairs, fro escapes or any structural members. Nate: The approval of the Ter- ritorial Board of Healbh shall Ge obtained on all building permit ap- l:lications, before sucks construction wor_~ is undertaken. Buildings to be moved on or across streets or other public thor- ougP.fares in whole or in sections shall also have the approval of the Counts' Engineer before the work cf moving is started. Section 1.111. FEES FOR PER- 94ITS, for inspection by the Build- ing' Inspector shall be ae follows: R'orlc to cost not more than ,3100.00-the sum of $1.00. Wot_~c to cost more than $100.00 and not more than $500.00-the sum of $2.00. V JOrIC to cost more than $500.00 anal not more than $1500.00-the sum of $3.00. 4Jorlc to cost more than $1500.00 end not more titan 52400.00-the a:u:u of $4.00. Worh to coat n.ore tixon 5250000 and not mote luau $3500.00-the suxn of $5.00. Werlc to coat more than $3500.00 ~ , ,~ ki' ~ and not more than $5000.00-the sum of $7.50. Worlc to cost more than $5000.00 and not more than $100,000.00-$7.50 far the first $5000.00 and 10 cents for each $100.00 or fraction t9tereot in excess of the sum $5000.00. Work to cost more than $100,000.00 -$110.00 for the ffist $100,000.00 and S cents for each $100.00 or fraction thereof in excess of $100,000.00. Section 1.112. MORE THAN ONE 6TRUCTURE. Where separate structures are contemplated on the same site, one permit may be issued and the charge made as though one structure were contemplated, pro- vided such application covers one contract or project as a working unit. Section 1.113. FILING OF PLANS. Plans axtd specifications fot• all work to cost more than One Thousand Dollars ($1000.00) shall be filed with the Building Inspector. Plans in du- plicate shall Ue permanent process copies or ink lined drawings on per- manent paper and shall show suffi- cient detail to clearly define the etrnctttral elements and general character of the word proposed. In tkxe case of a new building or addition a plot plan showing the location of the building with rela- tion to other buildings on the same property, if any, must be filed. One set of plans with the mark of approval of the Building Inspec- tor shall at all times be kept on the work. Specifications shall be typewrit- ten or permanent process copies. Pencil copies of plans or spe- cifications shall not be accepted. Fer work costing less than Ono Thousand Dollars (51,00200) a statement mt au approved form set- ting Corth the Uarticulars oC the work may be Ciled in lieu of plans and specificatioxts. (Note: See Act 165, S. L. 1931, regarding a licensed architect or engineer on Certain works) Section 1.115. AMENDMENTS TO ITLEll PLANS. Any change involy- ing elements prescribed by this Code in the details of the plans and specifications after the issuance of the building Permit therefor, shall be made as a separate plan and filed in duplicate, bqt otherwise in the same manner as the original application. IP no increase in cost i, involved. no additional charge shall be made for the amendment permit. Sttch amending permit shall be obtaived before any change is made in the original planned work. Section 1.116. PERMITS FOR TEMPORARY FRAME STRUC- TURES WITIIIN THE FIRE LIM- ITS of the City oT Idilo. Temporary sheds and buildings may also be ererted when gsed in connection with the erection, alteration or re- pair of permanent buildings, if such is approved by the Building Inspector. Section 1.117. APPROVAL OF PERMITS BY FIRE CHIEF. No permit shall be issued for the erec- tion, alteration or removal of any building for public assembly with- in the fire district of the City of Hilo unless approval therefor be first obtained from the Chief of the Hilo Fire Department. It shall be the duty of the Fire Chief to inspect all such building plans, visit the work dttring construction and make him- self familiar with all such new structures. Section 1.118. PERMIT INVALID. The Building Inspector shall not is- sue any building permit for any building or structure to be erected in violation of the building code, and any such permit issued contrary to the building code shall be void. Section 1.119. RESPONSIBILITY FOR DAMAGE. The approval of any plans and specifications shall not relieve the architect, engineer, ecntractor or owner from any ]iahl- lity as regards damages or loss of ,j ~,~' life from the failure of any sU•ucture or part thereof, or from any liability that may accrue by reason of the use or occupancy by either oT such persons of the sidewalks, street, or sub-sidewalk space, or any liability that may accrue by reason of the axon-ecmpLiance by any of sucks persons with any of the provisions of the Building Code. Section 1.120. ISSUE OF PER- RIITS. The Budding Inspector shall without delay examine the plans and applications for a building per- mit, and s?ta11 determine whether such plans conform to the require- ments of law applloable thereto and the Building Code, and if the regturements be met, shall, upon payment of the stated fee, issue a permit to perform the work con- templated. Section 1.121. PERMIT POSTED 017 SITE. The applicant shall Cause the permit, or an approved copy thereof, to be conspicuously pooled on the site oY the work. Section 1.122. EXPIRATION OF PERMIT. If work authorized by auy permit has not commenced within 90 days of the issue thereof, cr if the a•orlc has been abandoned for the same period, or iP the work violates any of the provisions of the building Cade, such permit shall be- come null and void, and in the event of abandonment of work or failure to commence, a new permit with the fc-e therefor shall be required. Section 1.130. CERTIFICATE Or' OCCUPANCY. Upon the comple- tion of the construction or the a]- terations or the repairs of every building excepting dwellings, for which a permit has been issued, or c/hcnever iC is proposed to change the class of occupancy as defined elsewhere in the Building Code of a Buildin@;, a certificate of occupancy shall bo issued by the Building In- speetor; upon an approved fozm, setting forth the use proposed and the maximum live load and number of persons that may be accommo- dated on each floor. Such use shall conform to the requirements of the uses permitted in the Building Code. Provided that in the case of alterations or repairs where the use is in no way changed, a new certi- ficate need xrot be issued. Tempor- ary occupancy certificates may be issued by Uhe Building Inspector whore such change is necessitated b7 cYterafions or repairs, or similar tetnpcrary uses which do not defeat file spirit of the use restrictions else- where in the Hulling Code. Section 1.13E It shall be unlaw- ful for the owner and/or occupant of any building or structure here- after erected, altered or repaired to exceed the maximum allowances in his certificate of occupancy or to change the use or nature of the oc- cupancy without first obtaining a cer- Cfiaute oY occupancy as herein-be- ]ore, stipu'.ated, and each and every clay of such failure to comply with or to obtain a certificate shall con- stitute aseparate violation; provid- ed, however, nothing in this section ;.hall aplily to the class of occu- pancy of buildings lawfully existing znd used prior to the enactment of the requirements of this section. Sec Section 5.225. Section 2.140. CHANGE IN 000U- PANCY AND OTHER REQUIRE- MENTS. It shall be unlawful for any owner or occupant to fail to report a change in occupancy as provided in the foregoing requil'e- ments, or for any owner or occu- pant to fail to obtain a Certificate of occupancy prior to such occupan- cy or to give a misleading or false description of such occupancy, and the Building Inspector is hereby authorized and empowered to cause to be forthwith vacated any occu- pancy contrary to the requirements of the Building Code, and it shill be his duty to institute proceedings to prosecute all violations of this provision. Section 1.150. ALTERATION OF EXISTING BUILDINGS. No build- ing shall be enlarged or built upon unless at the completion oP such work the whole building and every part thereof shall conform to the Building Code, provided, however, that when any portion of a build- ing is cut or altered by necessity for public use, through conderrxna- tion proceedings or otherwise, as in the case of increasing the public ways, then it shall be lawful to re- pair the remaining portion with the same class of material as originally used thereon, and further provided that such repairs or changes do not violate the amount of such repairs stipulated in the Building Code. (See Sections 4:130 and 4.140 of this Code). And further provided that no enlargements to existing business buildings may be made in residen- tial districts. Section 1.160. COOPERATION WITH HEALTH DEPARTMENT OF THE TERRITORY AND THE VARIOUS COUNTY OFFICIALS. It shall be the duty of the Building Inspector to cooperate with the Ter- ritorial Fire Marshal and the Board of Health in all legal and proper matters in which there is a joint in- terest of Law and Building Code enforcement, and he shall also co- operate with the City Planning Commission, the Chief or Chiefs of Fire Departments, and all City and/or County officials in all mat- ters where there is a common de- partmental or official interesE. He shall also give free access to the tax assessor's oPIice of al] records in De- partment of Building office. The Building H~speotor may also recommend to the Board of Super- visors of the County of Hawaii, three qualified persons to constitute a Board of Electrical Examiners and three qualified persons to con- stitute a. Board of Plumbers' Exam- iners to cxamire the various appli- cant; who apply for license under the ordinance requirements of the County of Hawaii. The Electrical and/or Plumbing Inspector of the Department of Buildine under the cognizance of the Building Inspector shall he a member ox-officio and 6ecretary of the Electrical and ,Plumbers' Exam- ining Boards without additional v.ompenea ion. 'fhe three other mem- bers of the P.onrd of Electrical Ex- aminers shall each receive Ten ($10) Dollars for each day examinations are held and the three abhor mem- bers of the Board of Plumber's Ex- aminers shah each receive Ten ($10) Dollars for each day examinations are held, in examining apphcnnts for license in their respective branches and grades as provided by ordinance ENFORCEMENT Section 1J?10. BUILDING IN- SPECTOR. There is hereby created a Department to be known as the Department of Building, and the Chairman and Executive Officer with the approval of the Board of Supervisors, shall appoint a regis- tered Architect or Engineer as Building Inspector, to have charge of said Department. The salary o1 the Building Inspector shall be fixed by the Board. The person holding the office of Building Inspector may be removed froxn office at the pleasm•e of the Chairman and Ex- ecutive Officer with the concurrence of two-thirds of the Board. The Building Inspector shall maintain his office at Hilo and shall not engage in any other employ- ment or business, and shall have all the po•.vers, and shall perform all the duhics necessary, (ll. to see that al] of the requirements of the Building Cade are properly carried out, [2), to supervise the mainte- nance, structural condition and re- pair of al] public buildings and grounds under the control of the County government, exclusive of school buildings and grounds and public parks; (3), to keep an accu- rate record in such form as shat] be approved by the Auditor of the County of Hawaii, of all fees re- ceived, moneys allotted, expended and obligated, and other money transactions of his offioe; (4), to de- posit all fees received with the County Treasurer at least once each week; (5), to render an account of al] permits issued and moneys re- ceived, epee each month to the Board; (6), to maintain in his oi5ce for public inspection a record of permits issued, a map or maps showing the districts within the City of Hilo, or elsewhere in the County, which have restrictions of use axtd generally to keep available to fhe public all necessary information on building restrictions and the results oi' structural tests of methods and materials, departmental rulings and requirements pertaining do mat- ters hereinbefore delegated to him, and l7), to employ and remove an electrical inspector and/or a plumbing inspector and such assist- ants, clerks or other employes uPOn whom may be conferred by him the same powers as held by himself, and to employ and remove as may be neoessary to properly execute the duties of his office, when authorised so to employ, and at compensations fixed by the Board. Section 1.220. INSPECTOR'S RIGHT TO ENTER BUILDINGS. The Building Inspector ax1d the Fire Chief and their assistants, so far as may be necessary for the per- formance of his or their duties, s`ixall have the right of way to en- ter upon, at any reasonable time, any new or unoccupied building or structure under construction, re- pair, alteration or removal, or any building or structure alleged to be unsafe. Section 1.230. TEST OF MATER- IALS. The Building Inspector shall have the power to require bhe test- ing of any material, appliance or method of construction by disinter- ested Forties competent to execute such work. Such tests shall be, whenever possible, by methods adopted as standard by the Amer- ican Society for Testing Materials. No new class of structural material shall be used until shown by test to be adequate to fu'.flll the requirements of construction safety as indicated by the Building Code. Previous tests by competent parties may be ac- cepted in lieu of new tests by the Building Inspector. Section 1.240. CONDEMi7ATION AND REPAIRS. Whenever any structure is found to be whol- ly or partially iu a damaged condi- Cion, the Building Inspector shall notify and order the owner thereof 4o make the same safe and in con- formity with the requirements of the Building Code, or to demolish the same within such period of true as may be reasonable under the circumstances. It shall he aalawful for any own- er to maintain upon his premises any dangerotus shucture which has been so declared by the Building Inspector. Whenever in the judgment of the Building Inspector imminent dan- ger exists, as an emergency meas- ure he is hereby empowered to or- der such structure and/or adjoin- ing premises vacated until stteh danger is abated, and it shall be unlawful far any person to disre- gard such order. f Bee also Fire Marsha] and De- puty Fire Marshal's powers re: con- demnation and repairs. Section 3463, R. L. 1925) Section 1.250. PENALTY. Any person, firm or corporation violat- ing, or failing to comply with any of the provisions of the Building Code, as hereinbetore defined, shall upon conviction be punished by a fine not exceeding Five Hundred Dollars ($500) in the discretion of the court. 'fhe continuance of any such vio- lation aster conviction snail be deemed a new oRense ror each day of such continuance. Section 1.260. APPEAL FROM DECISION OF BUILDING IN- SPECTOR AND CBIEF OF FIRE UEPAR'iH1EIQT. An applicant who has been refused a permit or the holder of a permit which has been revoked, or any ene believing any m'der by the Building ?xvspector or the Chief of the Fire Department to be improper or unreasonable, may appeal from such decision as fol- lows: An application for a heating as hereinafter described, shall be filed in writing with the Building Inspec- tor together with a deposit of Sev- enty-flee Dollars ($75.00) whicix sum shall not be deposited with the Treasurer, other provisions herein to the contrary notwith- standing, but receipted for and dis- bursed as hereafter set forth. Unless the applicant and the Building Inspector shall mutually agree to leave the final settlement oP the issues to the decision of an Arbitrator who has had the required engineering or architectural train- ing or to a licensed engineer or architect, to be mutually selected by them, then, within three (3) days after the sling oP application as aforesaid, the Building Inspector shall appoint a disinterested licensed engineer or architect, the applicant shall do likewise, and the two per- sons thus selected shall appoint a third party who shall have had the required engineering or architec- tural training, and these three shalt constitute an Arbitration Board to hear all parties concerned at an ap- pointed time and place and shall consider the matter and points in- volved in the appeal. Their findings, decision or rulings shall decide the question at issue and shall be spat and binding upon the parties, sub- ject only to such action as allowed Uy law. All findings and decisions of such Arbitration Board shall be in writing and signed; one copy filed in the office of the Building Inspec- tor and one copy to the applicant. The decision of a sole Arbitrator need not be filed unless requested by either party. The Building In- spector shall furnish clerical and stenographic services required by such Arbitration Board with out cost. The County Attorney shall render legal services and advice upon request of such Arbitration Board. Should the question at issue be satisfactorily settled and the find- ings filed, if requested, by the aforesaid arbitrator, he shall be paid the sum of Twenty-five ($25.00) Dollars and the balance of the Sev- enty-five ($75.00) Dollars deposit shall be immediately returned to the applicant. Should the question at issue be placed before the aforesaid Arbitration Board, each member shall be paid the sum of Twenty- five ($25.00) Dollars from the Sev- enty-flue ($75.00) Dollars deposited with the Building Inspeotor, upon filing their fixdings. CHAPTER 2 DEFINITIONS Section 2.109. DEFINITIONS. The following terms when used in this code shall be construed to have Lhe meaning hero given them. Words used in the present tonne include the future; the singular number in- cludes the plural, the plural the sin- gular; the word "person" includes a copartnership and a corporation; "writing" includes printing and printed, photographic or typewrit- ten matter. Section 2.101. ADDITION means any enlargement. Section 2.1011. ALLEY is any pub- lic space, public park or thorough- fare less than twenty (20) feet but not less than ten (10) feet in width which has been deeded to the pub- lic for public use, or publicly ac- quired by right of prescription. Section 2.1012. ALTERATIONS mean any change. Section 2.102. APARTMENT HOUSE, Same as tenement. Section 2.103. APPROVED refers to any device, material or construc- tion which has been approved by the Building Inspector as a result of tests or investigations made un- der his direction, or upon the satis- factory evidence of competent or impartial investigation `conducted by others. Section 2.104. AREA OF BUILD- INGS. The areas of the horizontal cross-section at the ground level, measured to the center of party or fire walls and to the outside of other walls. Section 2.105. ASHLAR MASON- RY. Masonry of sawed, dressed, tooled or quarry faced stone, bonded. Section 2.106. ASHLAR FAC- INGS. Ashlar masonry used fn fac- ing masonry walls. Section 2.107. ASHLAR RAN- DOM FACING. Ashlar masonry of various sized members. Section 2.108. BASEMENT. A story partly or completely below the level of the curb. See "Story." Section 2.109. BEARING WALL. A well which supports any load other than its own weight. Section 2.110. BOARD, Shall mean the Board of Supervisors of the County of Hawaii. Section 2.111. BOARDING, LODGING OR CLUB-HOUSE. A building used for Hoarding or lodg- ing purposes containing not less than four (4) nor more than four- teen (14) sleeping rooris for guests. Section 2.111-1. BUILDING means a combination of materials to form a construction that is safe and stable, and adapted to permanent or con- tinuous ocoupancy for residence, business, assembly or storage pur- poses. Tha term "building" shall be construed as if followed by the words "or part thereof." Section 2.111-2. BUSINESS OR INDUSTRIAL DISTRICTS. These are defined in Chapter 5 of this Code. Section 2.112. CELLAR. That part of a building more than 40 0 of which is below the grade of the street, and in third class buildings that part which is below the sills but not more than seven (7) feet in height. It shall not be counted in determining the height or spacing of a building. On sloping lots, the mean elevation of the ground sur- face at the oorners of the cellar shall be taken for height determination. Section 2.113. CEMENT. The term cement shall mean Standard Portland Cement which meets the tzst specifioations of the American 6ociety for Testing Materials. Section 2.114. CEMENT MOR- TAR shall mean a mixture com- posed oP one (1) part Portland Ce- ment with not more than three (3) parts sand, and not more than fifteen (15) percent hydrated lime by volume. Section 2.115. CEMENT LIME MORTAR shall mean one (1) part Portland Cement, one (1) part of (lime putty) dry slacked lime or hy- drated lime and not more than six (6) parts of sand by volume. Section 2.116. CHURCH shall mean any building designed to be used, and used, as a place of wor- ship by any religious sect or organi- zation. Section 2.117. THE CITY OF HILO as used in this Code shall be that area included in the metes and bounds defined in Section 1576, Revised Laws of Hawaii, 1925, and any amendments made thereto. Section 2.118. CLASSES OF BUILDTNGS. For the purpose of this Code buildings are classed as FIRST, SEMI-FIRST, SECOND and THIRD CLASS buildings, and SLOW" BURNING HEAVY TIM- BER COTISTRUCTION BUILD- INGS. Section 2.118-1. C O N C R E T E BLOCKS. Precast hollow or solid blocks of concrete made in standard sizes to be laid in walls in mortar. Section 2.119. CURB. Whenever the curb refers to the height of a building, the weighted mean height shall be considered of the street frontage or frontages, that is, the mean considered shall be the sum of the products of the average front- age curb elevations and their hori- zontal lengths divided by the total horizontal frontages, provided, how- ever, that not more than 300 feet of frontage be considered at one tim°. Section 2.120. CURTAIN OR PA- NEL WALLS. Any exterior non- bearing wall between columns or piers, which is not supported by beams or girders at each story, or in skeleton construction a non- bearing wall supported by the build- ing frame at each floor. Section 2.121. DEAD LOADS. Dead loads shall mean the weight of the floors, walls, roofs, partitions, and all permanently attached con- struction. Section 2.121-1. DISTRICTS. These are defined Under Zoning, in Chapter 5 of this Code. Section 2.122. DWELLINGS. A residence building designed for use as the home of not more than two (21 separate and distinct families. A dwelling within the meaning of this Code shall include necessary out- buildings, servants' quarters and private garage therefor, and may include a private stable for not more than three (3) animals, or a separ- ate garage with stalls for not more than four (4) cars. Section 2.123. EXTERIOR WALLS. Any outside wall of a building other than a party wall. Section 2.124. FACED WALL. A wall having a bonded facing which acts as an integral part of the wall. Section 2.125. FACTORY. A building or portion thereof designed goods, wares or merchandise, the or used to manufacture, assemble work performed wholly or partly by machinery. Section 2.125-1. FENCES. A solid or other type structure not to ex- ceed eight (8) feet in height, and in Fire Districts to be constructed of incombustible materials. Section 2.125-2. FIRE DIVISION WALL, is a wall of masonry or re- inforced concrete which sub-divides a building to restrict the spread of fire, such wall beginning at the foundation and extending continu- ously through all stories to and above the roof. Section 2.126. FIRE-DOOR. A door frame and sill which will suc- cessfully resist fire for one (ll hour in accordance with the test specifi- cations of the Underwriters' Labor- atories. (See Section 11.600 of this Code.) Section 2.127. FIRE LIMITS. Fire limits shall mean Fire Districts Nos. 1, 2, and 3, as defined in Chap- ter 4 of this Code. Section 2.127-1. FIRE-PROOF. A.s used in this Code, except as else- where prescribed by test for particu- lar types of construction, refers to materials or construction not com- bustible in the temperatures of or- dinary fires, and which will with- stand such fires without serious im- pairment of their usefulness for at least one hour. Section 2.128. FIRE RESISTING. For the purpose oY this Code a five-ply felt, car and gravel, or gal- anized corrugated iron roof over woad framing or sheathing, lath and plaster work, fire doors and shutters of woodwork completely covered with sheet metal which comply with sections 2.128 and 2.130 hereof when approved, wire glass, or any material of equal or greater fare-resistive properties than these enumerated, if such is approved, shall be consideerd fire-resisting, and only such construction and materials of construction not com- bustible in the temperatures of ordi- nary fires and which will withstand such fires without serious impair- ment of their usefulness for at least one hour. Section 2.129. FIRE WALL. A wall which subdivides a building to prevent the spread of fire. (See Sections 9.470 to 9.474 of this Code.) Seotion 2.130. FIRE WINDOW. 9 window with frame, sash and glazing tvhich will successfully resist a fire for one hour in accordance with the Standard Test Specifications of the American Society for Testing Materials. (See Section 11.800 of this Code.) Section 2.131. FOUNDATIONS. That part of a wall below the level oP the highest part of the street curb, or if a wall is not on a street, that part of the wall below the le- vel of the highest ground next to the wall or that part of a party or partition wall below the cellar floor. Section 2.132. HEIGHT OF BUILDINGS. The vertical distance from the curb level to the highest point of the roof beams in the case of flat roofs, or the average height of gable in the case of roofs hav- ing pitch of over 20° with the hori- zontal. In case of buildings not flush with the street, the height shall be measuretl from t'he average height of the corners of the buildings. In measuring the height of a wall the height of the parapet shall not be included. (See Sections 2.122 and 2.119 of this Code.) Section 2.133. HOTEL. Any build- ing or portion thereof designed or used far supplying shelter and/or food to residents or guests and con- taining more than fourteen (14) sleeping rooms for guests. Section 2.133-1. INDUSTRIAL DISTRICTS AND USES. Defined under toning. Chapter 5 of this Code. Section 2.134. LIME MORTAR shall mean a composition of one (ll part slaked lime (lime putty) or dry hydrated lime, and not more than four (4) parts sand, by vol- ume. Secticn 2.135. MASONRY. Stone, brick, concrete, hollow tile, con- crete block or file gypsum block, or other similar building units or mat- erials or a combination of the same, bonded together with mortar to form a structural part of a build- ing. Section 2.136. MEASUREMENTS OF DISTANCES. The distance be- tween buildings, or the distance to the lot lines shall be taken to mean the minimum distance measured horizontally from any portion of the building projected vertically giving the minimum measurement. Eaves and cornices to the extent of 2' 6" are exempt. Exterior wooden steps not exceeding seven (7) feet in height and metal or fire-resisting exterior ladders or stairs are ex- empt. Section 2.137. MEZZANINE STO- RY OR FLOOR. A partial low story introduced in the height of any sto- ry of a building which shall be not less than seven (7) feet clear height, either above or below same. The total of such mezzanine floor shall not exceed 50 per cent of the area of the floor in the room in which such mezzanine floor is con- structed. If the area of such floor exceeds t'he above limit it shall for the purpose of this Ordinance be considered as forming an addition- al story, Section 2.135. NATURAL CEM- ENT MORTAR. A mortar composed oY one (ll part nahural cement to not more than five (6) parts oP sand, by volume. Section 2.138-1. OCCUPANCY. For the purpose of this code the word "occupancy" means the purpose for which a structure is used, that is, the nature and kind of use to which it is devoted. Section 2.139. OFFICE BUILD- ING. Abuilding which is intended and used for office purposes, no part ox which is used for living pur- poses except by the janitor and his family. Section 2.141. PARAPET WALL. That portion of a wall which ex- tends above the roof line and bears no load except as it may serve to support a tank. Section 2.142. PARTITION WALLS. An interior subdividing wall, other than a lire wall. Section 2.143. PARTY WALL. A wall that separates two buildings, and which is used or adapted Tor the use of more than one building. Section 2.144. PENT HOUSES. A structure erected on the roof of a building for the purpose of enclos- ing stairways to the roof, elevator machinery, water tanks, ventilating apparatus, exhaust chambers, ox other Uuilding equipment machinery housing, or janitor's quarters. When used only far the above enumerated purposes and not exceeding 14 feet in height above fire ceiling oY the story below, such structures shall not be considered in determining the height of a building. Section 2.145. PIERS. All bearing columns of four (4) square feet or less, not banded into adjoining walls. Section 2.146. GARAGE means a building, shed, or enclosure, or a part thereof in which a motor vehi- cle containing volatile inflammable oil in its fuel storage tank, is stared, honsed or kept. This ahall include a motor vehicle repair Shop iP there is gasoline in the tank of any car. Section 2.146-1. PRIVATE GAR- AGE means a garage mr not more than three motor vehicles, in which no business or industry connected .directly or indirectly with motor vehicles is carried on. Section 2.146-2. PUBLIC GAR- AGE means a garage not included within the term "private garage:' Section 2.148. PUBLIC HALL. A public hall is a room for public as- semblages, having a total seating capacity of one hundred (100) or more persons, but which does not include a theater. Section 2.149. REINFORCED CONCRETE shall mean an approv- ed concrete mixture in which steel or other metal is embedded in such a Wanner as to resist tensile stres- ses, and/or add rigidity and strength to concrete in compression. Section 2.150. RETAINING WALL is any wall used to rest lateral displacement of any material. Section 2.151. RUBBLE, COUR- SES. Masonry composed of approx- imately squared stones fitting on le- vel beds and well bonded. Section 2.152. RUBBLE, RAN- DOM. Masonry composed of rough- ly shaped stone, laid without reg- ularity of coursing, but fitting toge- ther to form well-defined joints. Section 2.153. RUBBLE, ROUGH OR ORDINARY. Masonry composed of uxtsquared field stones laid with- out regularity of field ooursing. Section 2.154. RUBBLE OR BOULDER CONCRETE. Portland Cement Concrete in which the finer materials form a matrix for large stones and boulders. Section 2.155. STORY. A story is that part of a building between any floor and the floor or roof next above. Section 2.156. STREET. A pub- lic or private open passage, lane or right of way at lest twenty (20) feet in width suitable or intended for pedestrians and vehicles. Build- ings abutting public parks, beaches or similar permanently open spaces shall be considered to abut a street on such abutting side. Section 2.15'. STRUCTURE. In- cludes the terms buildings, appur- tenances, wall, platform, staging or flooring used for standing or seat- ing purposes, a shed, fence, sign ar bill board on public or private prop- cx~ty, or on, above, or below a pub- lic highway. Section 2.150. TENEMENT HOUSE OR TENEMENT. Shall in- clude apartment house or apart- ments and shall designate any house cr building or portions thereof which is designed, built, rented, leased, let or hired out to be oc- cupied or whioh is oocupied as the k:oxuc or residence of three or more familiea living independently of each other and doing their cooking in the building. Section 2.159. THEATER. A building containing a romn for athletic, theatrical or operatic ex- hlbltions or other public entertain- ments, having a total seating capa- city of 300 or more persons. Section 2.160. THICKNESS OF WALL shall mean the minimum thickness of the wall exclusive of any protective covering. Section 2.ipi1. VENEERED WALL. A non-bearing masonry facing cov- ering the bearing construction. Section 2.162. WIRE GLASS. Glass not less than one-quarter P/,) inch in thickness enclosing a layer of wfre fabric reinforcement having a mesh not larger than soven- eighths f?k) of an inch and the size of wire not less than 24 Brown & Sharpe gauge. Section 2.103. WATERFRONT. Shall mean the contour of the mean lower low tide. Section 2.164. WAREHOUSE. A warehouse is a building used for the storage of goods, wares or xner- chundse. CHAPTER 3 CLASSIFICATIONS Section 3.100. THIRD C L A S S BUILDING RESTRICTIONS ON OCCUPANCY. No third class build- ing shall be used for any of the fol- lowing occupancies: 1. .^eaters. 2. .easements, hotels, apartments, boarding houses, clubhouse, or any axe otikter than as a private dwell- ing, housing not more than two (2) families, if such third class Uuilding is more than two (2) stories in height. Provided ,however, that the foregoing shall not apply to indus- trial buildings such as crusher plants, ohemical plants, elevator towers or similar industrial struc- tures which are not for Lhe storage of combustible materials and which have a human occupancy of not more than ten (10) people during the hours of their employment. Section 3.200. CLASSIFICATION OF TYPES OF BUILDING CON- STRUCTION. For the purposes of this Code buildings shall be classi- ficd into flue (5) general types oP construction-First, Semi-first, Sec- ond and Third Class, and Slow Burning Heavy Timber Constx•uc- tion, each of which is defined as follows: A FIRST CLASS BUILDING is constructed of non-combustible materials throughout with floors and root constructed of steel or re- inforced concrete beams, filled be- tween with terra cotta tile, or con- cxrote, or masonry arches, or with concrete or reinforced concrete slabs and otherwise constructed as iu this section provided. The outer walls shall be constructed of con- crete, brick, stone, hollow terra cot- ta tile, wncrete blocks or similar approved materials. No woodwork or other combusti- ble material shall be used in con- struction of any First Class Build- ing except wooden floors, sleepers, grounds, bucks and nailing blocks when entirely embedded in incom- bustible material, also the finish flooring and the interior doors and windows when not otherwise speci- fied, with their frames, trims and casings, and also interior finish when solidly backed wit4t fireproof materials may be of wood. Finish within the meaning thereof shall include ornamental paneling on the walls when such does not exceed three-fourths ('yi) inch in thickness and is backed with fire-proof mat- erials. There shall be no air space under Lhe finished flwring. All exposed structural steel shall be fireproofed with cement plaster, terra cotta or other fireproofing maicrial as elsewhere prescribed. lSee Chapter Il-Section 11.210 of Gh15 Code) Within the Fire and Industrial Distracts, First Class Buildings shall be provided with fire doors and shutters or wire glass and metal frames uu all exterior openings which do not abut a street. Such fire doors and shutters shall be ap- proved. (See Fire Doors and Win- dows-Sections 11.600, 2.130 and 2.135. Also Chapter 7 oP this Code) A Semi-First Class Building is a building constructed in all respects as prescribed herein for first-class building, except that the roof may be of wood planking not less than two l2) inches thick with splined or sitip-lap joints supported on steel or heavy timber trusses, or beams of steel or heavy timber or reinforced concrete, and with the plank covered with terracotta tile, slate or other incombustible material. The steel trusses ox beaxns shall be protected by behtg en- closed in concrete at least one and one-halt fPh) inohes rohick, or by being wrapped with metal lath and plastered at least one (ll inch thick, or by a suspended ceiling of metal lath and plaster. Within the Fire and Industrial Districts and Business Districts, Semi-Firct-Class Buildings having exterior openings which da not face an abutting street shall be protect- ed v/ith approved fire doors and shutters or metal Prames and wire- glass. (See Fire Doors and Win- dows-Section 11.600, 2.126 and '2.130 and Chapter 7 of this Code) All restrictions in this ordinance referring to second-class Buildings shall apply to Semi-First Class Buildings, exoept restrictions as to floor area. (See Section 4.301.) Semi-First Class Building may not be ereoted within the First Fire District, A SECOND CLASS BUILDING is a building with walls of brick, concrete, or equivalent approved masonry or fireproof material with floors and partitions of wood joist and stud construction, with all col- umns, walls and ceilings lathed and plastered, or protected with other equivalent fire-protective covering the supporting posts and girders may be of protected wood or of me- tal protected as required by Chap- ter 11 oP this Code, with the roof covering 5-ply felt tar and gravel aver wood sheathing, or corrugated iron over wood framing or sheath- ing or other equivalent exterior fire-resisting Covering. Within the Fire and Industrial Districts and Business Districts, Second Class Buildings having ex- terior openings which do not face an abutting street shall be protected with approved fire doors and shut- ters or metal frames and wire glass. cSee Eire Doors and Windows-Sec- tions 11.000, 2.130 and 2.135. See also Chapter 7 of this Code.) SLOW BURNING HEAVY TIM- BER CONSTRUCTION. The term "Slow Burning Heavy 'Pimber Con- struction" shall designate bulldings having outside parapeted walls of masonry, fire doors and windows on all sides not facing a street or streets, roof oP two (2) layers of full 1" lumber, laid with broken joints and covered with 5-ply tar and gra- vel or equivalent fire-resisting roof- ing and supported by beams and columns, rather than trusses, with laminated floors at least 3" in thick- ness, laid on heavy beams not less Lhan 6" wide, or with fire-proof ftoms, with no concealed spaces in the wood structural portions, with no partitimxs of wood, and with the stairways or elevator shafts enclos- ed with masonry and fire doors, and the whole construction so de- signed that fire may be readily hosed from outside the building and all combustible portions construct- ed of heavy timber to insure their slow combustion in the event of fire. THIRD CLASS BUILDINGS are all those not First or Second Class or Elow Burning Heavy Timber Oonstruction as hereinbefore de- scribed. CHAPTER 4 GENERAL BUILDNGG RESTRIC- TIONS IN THE CITY OF HILO Section 4.100. FIRE LIMITS. The Fire Limits of the City of Hiio shall consist of Fire Districts Nos. one Ill, two (2) and three (3), as de- fined in Sections 4.110, 4.120 and 4.130 hereof and the Business Dis- tricts elsewhere set aside Por busi- ness purposes (See 6ection 5.190 of this Code.) Section 4.110. FIRE DISTRICT No. 1 shall Include that portion of the City within the following boun- daries as defined in Ordinance No. 54, as amended by change of street names: Beginning at a point on the bank cf Wailuku River on the center lluc of I{inonle Street extended; Thence running southerly on the center line of Kinoole Street to a point in the center of Kalakaua Street; Thence running northeasterly on the center line of Kalakaua 6treet Go a point at the water edge of FIilo Bay; Thence following northerly along the shore line of Hilo Bay to the bank of said Wailuku River to the point of beginning. Section 4.100-1. FIRE DISTRIOT NO. 2. That the boundaries of Fire District No. (2) of the General Fire Limits of the City of Hilo should be as follows: Beginning at a point at the inter- section of center lines of Kalakaua Street and Kinoole 6treet; Thenoe running southerly on the center line of Kinoole Street to a poix.c in the center of Kinoole Street and one hundred (100) feet from the south side of Kalakaua Street; Thence running northeasterly parallel to and one hundred (100) feet from the south side of Kala- kaua Street to a point one hundred (100) feet from the southwest side of Keawe Street: Thence running southerly parallel to e.nd one hundred (100) feet from the southwest side of Keawe SLreet to a point in the center line of Mamo Street; 'T'hence runninE northeasterly on center lice of Mamo Street to a ,point In the center line of Keawe Street; Thence running southerly on the center line of Keawe Street to a point in the oenter of Kilauea Ave- nue; Thence running southerly on the center line of Kilauea Avenue to a paint on the center line of the Ha- waii Consolidated Railway, Ltd.'s Right of Way spur track to the Ha- waii Mill; 'thence running easterly on the center line of the Hawaii Consoli- dated Railway, Ltd.'s Right of Way directly across Mooheau Park to e point on the water edge of Hilo Bay; Thence following northerly along the shore line of said Hilo Bay to a point in the center line of Kala- kaua Street; Thence running southwesterly on the center line of Kalakaua Street to the point of beginning. Section 4.100-2. FIRE DISTRICT NO. 3. That the boundaries of Fire District No. Three (3) of the General Fh'e Limits of the City of Hilo should be as follows: Beginning at a point on the bank of the Wailuku River one hundred (100) feet from the west side of Kinoole Stx'eet extended; Thex:ce running southeasterly parallel to and one hundred (100) feet from the west side oP said Ki- nools Street to a point one hundred (100) feet from the south side of Haiti Street; Thence running easterly parallel to and one hundred (100) eeet from the south side of Haiti Street to a point one hundred (100) Peet from the soutl-,west side of Kilauea Ave- nue; Thence running southeasterly pa- rallel to and one hundred (100) feet from the south side of said Kilauea Avenue to a point one hundred (100) Peet Prom the south side of Ponaha- wai Street; Thence running easterly along the Ilawaii Consolidated Railway, Ltd.'s Right of Way to the center of Kilauea Avenue; 'Phcxca running' nortnwesterly along' the center oP Kilauea Avenue to the center oP Keawe Street; Thence running northwesterly on the center line of Keawe Street to the centsr ]lne of Mamo 6treet; Thence running southwesterly on the center line oP Mamo Street to a point in the center of Mamo Street one hundred (100) feet from the southwest side oP Keawe Street; Thence running northwesterly pa- rallel to and one hundred (100) feet from the southwest side of Keawe 6treet to a point one hundred (100) feet from the south side of Kala- kaua Street; Thence running southwesterly parallel to and one hundred (100) fret from the south side of Kala- kaua Street to a point in the cen- ter of Kinoole Street; Thence running northerly on the center line of Kinoole Street ex- tended to a point on the bank of the Wailuku River; Thence running westerly along the bank of the Wailuku River to the point of beginning. Section 4.130. CONSTRUCTION REQUIRED IN FIRE DISTRICT NO. 1. Ecery building hereafter to be erected within Fire District No. 1 shall be first Class construction as defined in Section 3.200. Provided, however, that buildings without walls may be erected as provided in Section 4.500. Buildings extending into another district shall be of the construction required in the more stringently regulated distrlet, unless a division fire wall is constructed making, in effect, two separate buildings. In addition to the above restrictions, all buildings shall con- form to Cne requirements oP height, area of lot covered, fire pipe lines, fire escapes ,and structural require- ments elsewhere Provtded 1'or in this Cude. (See particularly SecGtons 310u, 4.430 and Chapter 7.) This section shall be construed to affect existing buildings when altn~ations and/or repairs on such Uotal more tnan one hundred percent (100%) of the assessed value of the struc- ture in the case of Second Class buildings and slow burning heavy timber construction buildings, and fifty percent (50 ib) of the assessed value of the structure in case of Third Class Buildin^<. The assessed value used shall he 'cat for taxation purposes and ;~~all be taken just prior to the px cposed repairs. When the total c_ alterations and/or repairs exceed the above, such structure shall be made to entirely conform to the requirements of this Section, or shall be removed. Provided further, that when any part of an existing building is tak- en for public use by coudumna- tion, or otherwise, it shall be lawful Co repair the remaining portion of such building with materials sim- ilar to those with which the build- ing was originally constructed. Provided further, that nothing in the foregoing requirements for First and Second Class Building's within Fire District No. 1, Flre District No. 2 ai a Pyre District No. 3 shall be construed to affect Third Class temporary buildings to be erected in acoordance with the following re- quirements: 1. Permits for such struotures shall expire thirty (30) calendar days from the date of issue. 2. Such structures shall be con- fined to open lots, parks or similar open spaces and span not be closer than twenty (20) feet to the ,nearest CxlSting StrnetllTCS. 5. Such structures shall be so constructed and maintained as to reduce the probability of fire to a reasonable minimum and shall be subject to the approval of the Build- ing Inspector and shall conform to the requirements of structural safe- ty provided in this Code. Section 4.140. CONSTRUCTION REQUIREll IN FIRE DISTRICTS NOS. 2 and 3. Within Fire Districts Nos. 2 a.nd 3. every building here- after erected shall be of First Class, 6em1-Fist Glass, Second Class, or Slow Burning Heavy Timber Con- structi :;, as defined in Section 3.200, provided, however, that buildings without walls may be erected as provided in Section 4.500. Buildings extending into another district shall 6e oL the construction required in the more stringently regulated dis- trict, unless a division fire wall tvtthout openings is constructed, rrakixzo', in effect, two separate buildings. In addition to the above, all buildings shall conform to height restrictions, area of build- ing without firo walls, area of lot covered, fire pipe lines, 5re escapes and structural require- ments as elswehere provided for in this Code. Provided, however, that this Section shall be construed to affecC existing nonconformh~g build- ings when the alterations on such total more than fifty percent (50 I ) of the assessed value of the struc- ture just prihr to the proposed al- terations, in which event Lhe owner shall make the entire building con- form to the requirements of this Chapter and/or remove the struo- ture or adopt such other procedure as may conform to the intent of this Section. All fences constructed in fire districts shall conform to the requirements of section 2.125-1 of this Code. Section 4.150. CLASS OF BIIILD- ING IN DISTRICTS OUTSIDE THE FIRE LIMITS. Within Indus- trial Districts of the County of Ha- v/aii, buildings may be First, Semi- First, Second or Third Class Build- ings, or Slow Burning Heavy Timber Camstruction, but subject, however, to the spacing, area and height or other applicable require- ments elsewhere in this Chapter. iFOr spacing see Section, 4.330; for height see Section 4.200; and for definitions oP classes of building see Section 3.200 of this Code) Section 4.200. HEIGHT RE- STRICTIONS. No building or stx'uc- ture hereafter ereoted, except church spires, water towers, olock towers, :anokestacks or chimneys, shall exceed in height twice the width of the widest street upon which it fronts within Fire District No. 1 or one and one-half times the width of the widest street upon which it fronts in Fire District Nos. 2 and 3, or once Lhe width of the widest street upon which it fronts within the remainder of the City of Milo, nor shall Lhe height exceed the following limits elsewhere in the County: Scone Ht. Stories in feet Frmme buildings used Pox purposes other than a single dwell- ing _ __._........____.. 2 30 Frame dwelling oc- cupied by hat mare than one family.... 3 35 Buildings having bearing walls of hollow terra cotta _ building tile or con- crete blocks (See Section 9.42ll ._ 4 50 Second Class Build- ings ___._.._....______. 4 55 Slow Burning Heavy Timber Oonstruc- tion 5 65 First Class Buildings.. 7 80 Semi-First Class Buildings _.__._____ 7 80 If a single story building exceeds thirty (30) feet in height the roof shall be 5ro-resisting. A single story building not ex- ceeding thirty (30) feet in height may have a skylight, monitor ar penthouse, not exceeding ten (10) feet in height, no such penthouse shall exceed one-fourth of the total area of the building, and no such monitor shall exceed one-third of the total area of the building. Yrovxded that additional height on First Class buildings will be permitted above the height Limit oP eighty BO) feet provided such additional con- strtxetion is act intersected by any line making an angle of thirty (30) degrees with the verf.ical and orig- inating from the height limit of eighty (30) Sect cn the exterior proncrty lin.;: and continuing to its intersection with the interior prop- erty ]inr~ Exterior property lines refer to those boundary liars bor- rlering ox. a street as herein de- fined. Section 4.300. AREA RESTRIC- TIONS, FIRST CLASS BUILD- INGS. All First Class Buildings used fm~ public ge therings, light and pow- er sUations, office buildings, machine shops, foundariea, factories, and other similar buildings, where little or no tnflainmable material is stnek- ed or kept shall have no restrictions as to area. Section 4.301. FLOOR AREA RESTRICTIONS, for Semi-First Class, Second Class and Slow Burn- ),ice. Heavy Timber Construe±kon Buildings shall be in accordance with the following' table: Second-Class and Slow Burning Heavy Sari-First Timber Con- F'roeting Claw strucl;ion on Buildings Bnihfings 1 Street 10.000 sq. tt. 10.000 sq. ft. 2 SLreet5 12.500 12,500 " 3 Streets ]5.G00 15.000 " The above areas may be increased anc hundred percent (100%) if the building is equipped with an ap- proved automatic sprinkler system. In Semi-First Class Buildings, if fire walls are erected dividing the build- ing into floor areas not greater than Lhose given in the above table, then Lhere shall be no limit to the total floor area. Such fire walls shall be constructed of approved masonry or ro:~uforceil cauctt~fe or of bric)c, four (4) inches tixick, laid in cement- nx o r t a r, or cement-lime-mortar plastered on both sides, not less than one-half PFz) inch thick hollow clay, or hollow eemerit the six (fi) inches thick, laid in cement- mortar or cement-lime-mortar plas- tered on both sides not less than one-naxx ult inch thick and having at least two (2) cells in thiokness of the partition, or cored gypsum blocks four (4) inches thick laid in gypsam mortar composed of one Q) part of retarded gypsum and not more than two (2) pasts of sand proportioned by weight, to whioh a fibrous binding material is added when necessary. 5'ection a.330. FLOOR AREA AND HEIGHT RESTRIDTIOIdS FOR THIRD CLASS BUILDINGS VJ7TY.IN THE INDUSTRIAL DIS- TFLICTS. (a) Third Class Buildings within Industrial Districts shall be built in accordance with the following areas and corresponding interior line dis- tances; except as provided in para- graph "Y' of this section. 0 0 v ~ ~ .~ ~ ~ w q ~'~, s o' J, o v ~ N '', ~ '~, ~ c. m I o ~'~ ~ m o m ~ o ~ ~. G c -~ B N . o ~ a o ~ G "s o o ~ o o~:, ~s V ~ V ;r ~ v L', I+ C ~ G `n' r3 V C m s ~ y o v o y c. Q Q ~; f.4 w 5' feet 10 1,000 2,000 3,000 10 feet 20 2,000 4,000 6,000 In the foregoing table, the mini- mum distances and areas are given, a.nd whichever distarces from either lot or boundary or the nearest build- ing gives the lesser corresponding area, that distance shall govern. tb) No Third Class Building with- in Industrial Districts shall be clos- er than five (5) feet to any interior loU boundary, or within Uen QO) feet eY any other building', nor shall it CXCCCd 6,500 SquftTe feet In area eX- a~pt as provided In paragraphs "d" e" and "f" (cJ Any Third Class Building may be built on any street property line provided the allowable area does not exceed the requirements of pa- ragraph "a" of this Section for dis- tance from the nearest buildings. td) Any Third Class building within Industrial Districts may be increased sixty-six and two-thirds percent (662/3 %) in area if equip- ped with approved automatic sprinkler system. (e) Third Class buildings within the Industrial Districts may be con- structed adjacent to each other pro- vided the sections arc separated v,dth a fire wall extending three (3) i'ect above the roof and six (6) inch- es on the sides with all openings protected with approved Ilre doors, and provided, further, that the floor area of any section shall not exceed 2.300 square feet nor shall any part of the structure be nearer than Ilftcen Ofi) feet to any interior lot boundary, nor shall it be over one (ll story, or thirty i30) feet in height, nor sllaa such adjacent structure be used as a tenement, ay;artment, or dwelling or living quarters CD Buildings of corrugated iron on steel 17amcs which contain no v/ood partitions or other combusti- ble material in their wnstrttction, and which house non-combustible materials, or are to br. used and used as factories, machine shops, foundaries, canneries, or other user in which little or no combustible materials are contahxed, may be constructed within the Industrial Districts in accordance with the following table, provided, however, that the maximtuu size of such bvi]dings shall not exceed 60,000 square Peet or one story in height. yo G r. o w to N 0 ~ % w s N A /+ N a ~ I M d ti y o mom, y y d q w d~ m o a, i C u C 3 N o ~ o ~ C C A i ~ G O O (J ax eo m nn,; ~~ G d C F G w nt~ m~ ~s° h `n ~ o o ° A a w w F. 5 min. 10 min. 10,000 20,000 30,000 10 20 2Q,000 40,000 60,000 Buildings constructed as above but which have all exterior walls constructed as required Por First Class Buildings, with all openings therein protected with fire doers and shutters, and which walls are parapeted above the roof, may be constructed as above provided ex- cepting that the walls of sash build- ings may be placed on the lot boundary line. 'Phe foregoing areas may be in- creased sixty-six and two-thirds percent (66 2/3";~) if equipped with approved automatic sprinkler sys- tem. Note: See definition oY Street, Section 2.150 of this Code. Section 4.340. RESTRICTIONS ON THIRD CLASS BUILDINGS OUTSIDE THE FIRE AND INDUS- 'pRIAL DISTRICTS. (a) Outside the Fire and Indus- trial Districts the areas of the Third Class Buildings and distances of said buildings from interior lot boun- daries shall be as follows: One Story Not Over 30 feet in Height. o i G ` ly Op °- Y w '~ V ~ x, d ~^ -. Q Ll~ N °' a U ~ V . . ~ .~ a`i ~ y w ti .~ ,~ o ~ Cw ti Cw w ~' o g v 'i i o ~ I q •+ F O .° S p C ~ Q ~.o v" w m su ' ro R ~~ o F C~ N Q Q w w w 5 10 1,000 2,000 3,500 10 15 2,000 3,500 6,000 15 20 3,500 6,000 8,000 20 25 6,000 5,000 10,000 M ore Than One St ory in He ight. 10 15 1,000 2,000 3,500 15 20 2,000 3.500 6,000 20 25 3,500 6.000 10,000 25 30 3.000 10,000 10,000 30 35 10,000 12,000 12,000 (b ) No T hird Cla ss Buildi ng in the City of Hilo and outsid e the Fire and Industrial Districts shall exceed 12,000 square feet in area fi nor shall the same be nearer any interior lot boundary than the mini- mum distances in the preceding tables, except that garages and ser- vants' quarters not exceeding 800 square feet or one story in height may be place)3 on the rear lot boundaries if such is approved. Section 4.400. RESTRICTIONS ON BUILDING ON INTERIOR LOTS. (a) No building which does not face a street for a distance of one complete ditnension of the building shall be in excess of the following table of allowable heights and areas: Dxstrict cr any other facings projections shall not exceed twelve (12) inches beyond the street property line, ex- cept that eaves not to exceed four (4) feet beyond the street property line may be constructed. Such pro- jections shall be less than five (5) percent of the area of the wall face, provided, however, that awnings as provided by Section 4.430 shall pe dxcluded. Section 4.430. AWNINGS AND MARQUEE AWNINGS are permis- sible in all districts, provided that such are not less than nine (0) feet above the sidewalk, clear meas- urement, and provided further that 2nd Class Bldgs. 3rd Class Bldgs. Max. Helgitt, Max. Heigh,, Story Max. Stor-y iKa-:. Area, sq. ft. Area. sq. ft. Not permitted Not permitted 2-30 ft. 5,000 Not permitted 2-30 ft. 6,000 1-25 ft. 1,500 2-30 It. 5,000 2-30 ft. 3,000 Fire District No. 1 __._..____..._.._..__._..__. Fire Districts Nos. 2 and 3..........._.._._._... Industrial Distract ._.._ _....._.._. Remainder of City of Y.ilo and County' Buildings shall be considered to face a street if no structure on the same lot other than a fence not over eight (8) feet high exists be- tween such buildxng and the street. (See Section 1;.156 of this Code for definition of Street.) (b) No Third Class Building shall be constructed on an interior lot over one .story or 30 feet in height. (c) In tho case of a deep lot which allows the construction of several buildings, but abuts a street, all portions of the lot bet and a line seventy-five (75) feet back from the street property line and which does not have a direot fronting on the street, shall be for the purpose oY this Chapter considered as an in- terior lot, and all buIldings erected thereon shall comply with the re- quirements for an interior lot. (d) Every building on an inter- ior lot shall be provided with an unobstructed minimum passage of five (5) feet for the occupants oP such building or buildings thereon and an additional one (1) inch width for oath ten (10) persons over fifty (50) persons who occupy or for whom accommodations are provid- ed by such building or buildings. A single apartment or dwelling shall he considered Uo accommodate five (5) persons. Section 4.410. FURTHER RES- TRICTIONS AS TO LOCATION ON PROPERTY. In addition to the foregoing spacings applicable to the Fire Limits, Industrial Districts :rod interior Lots, no building shall hereafter be erected within the Re- sidential Section of the Oity of Hilo or in the residential section of any town in the County of Hawaii, near- er I';nan five (5) feet to any inter- ior lot boundary provided that: (a) Garage and Servants Quar- ters not exceeding an area of s00 square feet or one story in height may be constructed on the rear property line if such is approved by the affected property ownere and is approved by the Building Inspector. Ib) Garages on the Joint Boun- dary of two owmars may be erected (if mutually agreed in writing„ which agreement shall be attached to the permit application), but shall not exceed one story in height or 800 square feet or area on each side of the common boundary. All garages shall have fireproof floors. Section 4.420. CORNICES AND WALL PROJECTIONS. Cornices, belt courses and all similar facings rot all First and 9econdClassBUfld- Ings shall be non-combustible, well anchored and so designed that fac- ings will not be shaken from the ba^l'ing. All anchors of fading, cor- nices, the or simL'ar veneers for such purpose shall be of copper, bronze or other corrosimr-resisting metal, or iron and steel completely enclosed with not less than one (1) inch of dense concrete protective covering. Ali such belt courses, bays, within the fire limits such are con- strucl:ed entirely oP non-dombustible materials. All awnings shall be se- curely braced and anchored and shall conduct the rainwater there- `rom into the building line, and under the sidewalk to the gutter. Section 4.440. CANVAS AWN- INGS. No ccmbustible awning shall be constructed on the interior wall lines of any building in the fire limits. Section 4.450. MINIMUM SPAC- ING RE:~UIREMENTS IN ALL DISTRICTS. Except as hereinbe- fore provided, ¢ll buildings except theaters, special industry buildings and tenement houses shall have un- covered spaces for providing light and air. These spaces shall be open to the sky from the top of the sec- ond story window sill and shall be in accordance with the following provisions: (ll Rooming Houses, Club Hou- ses, Hotels and Lodging Houses on lots other than corner lots: 20 0 of total lot area. (2) Buildings as enumerated in provision (D on corner lots: 7510 of total lot area. (3) All buildings not enumerated in provisions l1) and (2) on Lots other than corner lots: 10 I of total lot area. 4) All buildings not enumerat- ed in provisions (D and (2) on corner lots not exceeding 2,500 square fe~'~ la area: 5% of total lot area. (5) Ninen buildings are an cor- ner lots more than 2,500 square feet in area, that portion of the building upon the excess lot area over and above 2,500 square feet shall be pro- vided with open spaces in accord- ance with the requirements oY pro- visions (ll, (2) and (3), as the case may be, of this Section. e8) Every building other than buildings enumerated in paragraph f2) which occupies lots fronting on three [3) or more streets may oc- cuRy the entire lot area. (D The total area of the un- covered spades of all buildings which are more than seventy-five (75) feet in width and occupy the entire block front facing upon three (3) or more streets may be less by twenty-flue (26) percent than re- quired by provxsions (3). (4), (5) and (8) of this Section. t8) There shall be a clear space not less than flue (5) feet in width at and above the second-story win- dow sills between the rear line of every building and rear lot except corner lots. This shall not apply to buitdings which extend through from one street to another. <0) Ixr every court or yard the minimum width between walls shall be flue (5) feet. (10) 9dditions to existing build- ings snail be considered together with the original construction as on11' one complete unit for space re- quirements. Section 4.500. SHEDS A N ll BUILDINGS WITHOUT WALLS. Within any district garage sheds consisting of metal roofing and sup- ports will ue permitted-one (D story or twenty (20) feet in height, the sides of which are open and the interior exposed. Such sheds may Lava one Q) wall of masonry. On the exposed sides there shall be a rlrar space of not less than ten 1101 Icet between the edge of the eaves and any other structure. The expos- ed sides shall net be enclosed with metal wire or other obstruction, but shall be kept entirely open. No such shed shall be wider than thirty-five l35) feet, measured from eaves to eaves, but ma3' be of any length. Such sheds may also be erected on the roofs of First Class Buildings and in such cases the use need not be restricted to garage purposes, but the total height of the building and the shed shall not exceed the height limits required by section 4.200 of this Code. CHAPTER 5 ZONING Section 5.100. USE DISTRICTS. For the purpose of this Code the City of H11o, as defined in Chapter 2, is divided into the following IIse DistTlCLS: 1. Industrial Districts. 2. Noxious Industry Districts. 3. Business Districts. 4. Hota1 and Apartment Districts. 5. Residence Districts, single or multiple dwelling's. 6. Residence Districts for single family dwellings. Section 5.110. INDUSTRIAL DIS- TRICTS. Within the Industrial Districts as defined 6y Chapter 2 of this Code, all classes of uses are permitted with the exception of noxious industries as hereinafter defined. Section 5.120. NOXIOUS INDUS- TRY DISTRICTS. Within the Nox- ious Industry Districts any use is permitted excepting any building which is designed, arranged or in- tended to be used in whole or in part as a dwelling, hotel, lodging house, boarding house or tenement, or for any living quarters with the exception of one dwelling upon a premises for a watchman and his Iamily. The. term "noxious industry" shall be taY.eu Lo include such in- dustries as fertilizer works, soap works, fish canneries, g4ue works, chemical plants which emir, noxious fumes, asphalt plants, yas works, creosote treatment plan's, tanning works, slaughter houses, cremator- ies, lime Kilns, or a":y works or plants which emit noxious or offen- sive odors, fumds, gzs or excessive smoke. Section 5.130. BUSINESS DIS- TRICTS. Within the Business Dis- trial uso.. Phe term Industrial Uses shN] ha_ taken V includ, such usos as bode- and steel works, planing mills, lumbar yards, foundaries, ship works, canreries, oil storage plants, fartoria•' lannrirics end macbin^ shops employing more than five (5) people and all such works other than nox:ovs industries as defined in Section 5.120 of this Chapter. 6ection 5.140, HOTEL A N D APARTMENT DISTRICTS. With- in the Hotel and Apartment Dis- tricts, any use is permitted except- tricts, any use is permissible ex- cepting noxious industry and indus- ing noxious industry, industrial uses, and business uses. The term "Business Uses' shall be takdn to in- clude all retail irnd wholesale stores, shops, public garages, blacksmith shoes, milk depots, gasoline service stations, restaurants except in hotels or apartments, amusement houses, theaters. movin6 picture shows, dance halls, undertaking parlors, automobile sales rooms, automobile repair shops, small carpenter shops, office buildings, and similar uses other than industrial uses and nox- ions industries as defined in Sec- tions 5.120 of this Chapter. Section 5.150. RESIDE N T I A L DISTRICTS. Within the Residen- tial Districts only dwellings, board- ing houses, buildings for truck and flower gardens, greenhouses, hos- pitals, sanitariums, churches, schools and public owned buildings shall ba erected or used. Section 5.160. SINGLE FAMILY RESIDENCE DISTRICTS. Within Lh_ Single Family Residence Dis- tricts only single family dwellings and publicly owned buildings shall be erected or used. A single family dwelling shall include the same ac- cessory buildings Permitted for dwellings as defined in Chapter 2 of this Code. Section 5.170. NONCONFORM- ING BUILDINGS AND USES. Any building being used at the present time in non-conformity with the re- quirements of Chis Code may con- tinue such use, but any use now ex- isting' in non-conformity with this Code shall not be. changed into a different non-conforming use. Section 5.180. METHOD OF AP- P]~YING FOR RESTRICTED USE DISTRICTS. If the owners of prop- erty within any area in the Oity of Hilo desire a change in the use now oxisting of any district or por- t.lon thereoT, other than as provid- ed for business Districts as provided in Section 5.19q they shall present a petition upon forms to be pre- scribed by the City Planning Com- mission, accompanied by a map showing the property involved, and tho owners and rho areas involved, to the City Planning Commission. Such petition shall present the rea- sons therefor, and the area desired to be altered by the petitioners. Ex- cept in the case of business districts to be set aside within the residential dish'1ets, as hereinafter provided, such aria shall not be less than 50,000 square feet. The Planning Commission shall as soon as possi- hle pass upon such application, con- sidering the desirability and need for the orderly development of the City, and submit their recommen- dations thereon to the Board of Supervisors fur such action as may be advisable. Section 5.190. BUSINESS DIS- TRICTS IN RESIDENTIAL SEC- TIONS.Business Districts, Hotel and Apartment Districts may be revert- ed to Residential Districts, by a petition signed by sixty-five (651 percent oY the property owners within a radius of six hundred and fifty (L50) feet oP the Center Of the street front of the proposed di,- trict if such petition be granted by the Board. Leased property, the unexpired term of which is five (6) years or more, to be considered shall renuire the signature of both the owner and lessee, which shall be construed one signature for the purpose of computing the percen- tage of consent. All new districts shall be as nearly rectangular as practicable in shape, abut a publio street and shall be one hundred U 00) feet in depth from the street boundary where possible. Such Pe- tition shall be on forms furnished b3' the City Planning Commission, with whom such petition shall be filed in duplicate, and the sum of fifty dollars ($60.00) paid the Treas- urer of Lhe County for publishing and posting of notices, which post- ing shall be done by the City Plan- ning Commission at ]cast every two hundred (2001 fe°t tv±thin the pro- posed district ,and published at least two times within ten days in a paper published and oY general circulation in the County of Ha- waii. Such notices shall set forth all the requisite facts and set a date of public hearing before the Plan- ning Commission not Sooner than ten [LO) dogs Prom tho first pvblish- ing andi oC pn5ting of SUCK nat!Ces. At such public hearing the Citv Planning Commission shall note al] protests and suggestions offered. Names may be added to ox with- ds~awn from the petition up to the close of the public hearing. The Planning CommlSSion shall there- upon consider the petition, if such is still supported by sixty-flue (65) percent of the property owners, with particular reference to Lhe orderly development of the Oity, and chalk, if favorable action be determined, prepare an ordinance with the as- sistance of the County Attorney covering the matter and forward such, together with a report on the entire proceedings and their recom- mendations, to the Board for such action as may be deemed proper. In determining fire percentage Uf consent, all public areas shall be deducted from Lhe total area and all owners of property already using property for the purposes asked for in the petition shall be considered as having signed the petition in consent. Section 5.191. PLANNING COM- MISSION TO RECOMMEND CHANGES IN USE DISTRICTS. Tho City Planning Oommission shall recommend from time to time, either with or without petitions therefor, any changes, extension, re- tractions, corrections, adjustments or alteraC!ons that may appear to them desirable for the orderly dev- elopment of the city, to the Board of Supervisors for surh action as ntav be deemed advLSable. Section 5.192. BUSIN"E56 DIS- TI(1CTS TO BECOME PART OF I1S DST'RICTS NOS. 2 and 3. All districts set aside for business purposes in the City of Hilo =hall become subject to the regulations and privileges applicable to, or to beccrxte applicable lo, Fire Districts Na. 2 and 3, Provided that metal automobile service stations contain- ing little or no wood with metal roof and sides map be constructed in such districts providing that such building is not nearer than (20l Peet from nnv other buikding on Lhe same lot, or nearer any in- terior lot boundary than twenty r20) feet. (Note: No spacing is re- aull'ed within the fire limits on the side lines of the lot). Section 5.193. HOTEL AND ~~.PARTMENT DISTRICTS LIMIT- ATI01Q. SECOND CLASS BUILDINGS. Within the Hotel and Apartment Districts, second class buildings for hotels and apartments may be con- structed with any multiple of the allowable areas given iu the preced- ing tables for second class buildings, adjacent to each other, provide$ a masonry or concrete fire-division wall subdivides such areas. THIRD CLASS BUILDINGS. Within the Hotel and Apartment Districts, single third class build- ings for hotels and apartments shall be not more than two (2) sto- ries in height, nor shall the same be nearer any interior lot boundary Chan the minimum distance given in Che preceding tables of allowable areas. t Note: Far district Boundaries of Industrial Districts, Noxious Indus- try Districts, Business DisLrkets, Hotel and Apartment Districts and Residence Districts, see Ordinances and maps in the office of the Building Inspector) CHAPTER 6 LFGHT AND VENTILATION Section 6.100. LIGHT AND PEN- TILATION OF DWELLINGS. Each and every room ixrtended or used for kabitation shall be provided with at ]east eight B) square feel of window area having unobstruct- ed access into the open air for each one hundred (100) square feet of floor space is said room, and free eccess shall, at all times, be had to the same by the occupants of the room; and at least one-half ('-<) of such window space shall Fie mov- able and available for ventilation. No room designed or used for sleep- ing purposes shall have less Uhan seven (7) feet clear space between the rioor and tike ceiling for aC least two thirds (2/37 of its area, nor shall any such ceiling be less than five l5) feet above the average ground elevation adjoining such rooms. Section G.110. VENTILATION O"~' WATER CLOSETS AND URINALS. Every ap¢rtment or room conLflln- iug a water closet or urinai shall be properly ventilated by means of a window opening directly into the open air, provided, however, that an interior room coxxta;ning a water closet or urinal xnay be construct- ed iT sach room be ventilated by a positive mecitanicai system in such a manner as to completely change the atmosphere of such room aL toast six (6) times each hour. Section 6.120. LIGH'i' COURTa. Narrow courts or shahs for light and ventilation shall in no case be less than four (41 feet between walls. All openings into such courts in first and second class buildings shall be protecCed by metal frames and wire glass. Section 6.130. VENTILATION OF ATTICS, BASEMENTS AND CEL- LARS. No second or third class building shall be so constructed that unventilated spaces are left below the ground Boor or above the ceil- ing. Section 6.140. AIR SPACE UN- DEIt BUILDINGS. Every building slxall have at least twenty (20) in- ches of clear air space between the bottom of the floor joists and the top of Lhe highest point of Lhe ground, and shall be opened and cleared to a free access of fresh air and light at all times. This space s'not' not be excavated except in cases of full basements and cellars or in free draining sail. Provided, however, that flootis of masonx'y tiie or similar construction with or without woad surfacing may be used if such is so constructed that no poeLetS exist whioh might be- come rodent harbors or vermin in- icsted. Section 6.1.50. OUTSIDE DIS- TRICTS. Outside the City oi' Hilo as defined in Chapter 2, of this Code, no third class building shall be constructed nearer than five (5) feet to the property line, or ten (10) feet to the next nearest building on the same lot or of greater height than two (2) stork, if used for other than industrial uses. Provided, however, that single family residences may be three (3) stories in height. Theaters, public assembly halls, and moving picture show houses shall be subject to the same regulations for seating, ex- its, fire protection, and other regu- lations pertaining to theaters and moving Uicture houses within the City of Hilo. CHAPTER 7 MEANS OF EGEESS Section 71011. STAIRWAPS. 1. First, Somi-First and Second Class Buildings which are three (3) or more stories in height shall have at least two (2) stairways, except as provided hereafter, not less than thirty (30) inches wide each for ftte first flfry (50) oc- e.opants and one (1) additional ine.h of width for each ten 10) additional occupants. In Second Class Buildings these stairways shall be entirely enclosed with masonry fire walls of not less than eight Qf) inches of masonry; shall be protected at each floor, exeapt We etreot entrance, which may be left open, with self- closing fire doors which shall open with the direction oP exit and shall be unfastened except that panic bolts may be used. In First, Semi- First and Second Class Bufldings one stairway shall continue up to and enter upon the roof, but the last flight from the top floor to the roof may )x constructed with a metal ladder; and these stairways shad be built of first class construc- tion except as otherwise noted herein. Both stairways shall enter into streets or open spaces at the ground level deemed adequate for the occupants by the Building In- spector. One of such stairways shall have a standpipe as provid- ed in Section 11.910. Provided, however, that for first, semi-first, and second class warehouses, and other uses not for human oc- cupancy, and for all first, aemi- first, and second class buildings sot over two (2) stories in height and not over 4,000 square feet in area, only one (1) such stair- way shall be required, and fur- ther provided that horizontal exits constructed by means oY fire- proof balconies which lead around a party or fire wall, and the en- trances to which are protected with fire doors, or an exterior stair fire escape, may be deemed equiva= lent of a stairway as required here- in. Horizontal exits may be re- cessed into the building if the outer wall is open to outer air, or other construction, so as to obtain the same isolation as with the balcony above described. All balconies, stairs, landings and platforms required by this Sec- tion shall be designed for a live load of one hundred (100) pounds per square foot, and shall be pro- tected with substantial metal or mansory railings. (See Section 11.211, provisions 6 and 7 of this Code) In buildings not exceeding 7,500 sq. ft. in area, one of the two stairways may start from the sec- ond floor level, if connected by a corridor or other means of free access to the other stairways, and if the corridor has at least one opening in an outside wall. 2. Third Class Buildings o1 two (2) stories, other than single fami- ly dwellings and which are design- e•Y to, or do, accommodate more than five (5) persons on the second floor, and all two-story third class tenements, apartments, rooming houses, boarding 'houses and hotels shall be provided with not less than two (2) stairways, so located that no matter in which portion the fire might occur, one stairway shall be available to any occupants. These stairways shall lead to the ground floor and shall be not less than thir- ty (30) inches in width each, witlx an additional one /D inch for each person over ten O.0) persons to be accommodated on the second floor; horizontal salt may be used in lieu of one of these stairways. Section 7.110. ENTRANCES TO STAIRWAYS. In factories and warehouses all entrances to stair- ways as required 1n Section 7.100 shall be so proportioned as to be adequate for their portion of the stair width required, but in no case shall sucn doors be less than thir- ty-six (36) inches in width. Such entrances shall be so con- structed that access is made avail- able by an opening leading from the floor or story to an outside balcony, from which balcony an- other door leads into the stairway. The stairway shall be completely enclosed by eight (8) inch fire walls excepting on the outside, which shall be open to the outer air. Doorways shall be protected with fire doors. Instead of the balcony herein provided, a re- cessed stair well may be used, provided, however, that an addi- tional fire wall be constructed to enclose the stairway, with a fire door leading from the floor to the ante-chamber thus formed, and a second fire door leading into the stairways. The outside of the stair well shall be open to the outer air. No openings except Lo the street, or street side, or court at least l20) feet wide, stxall be constructed into stairways in first, semi-first and second class construction other than the fire tloors provided in Section 7.100. Such stair wells, however, may be provided with skylights at the top. Section 7.200. FIRE ESCAPES. Every building of three stories or more in height shall be pro- vided with adequate fire escapes, so located that no matter in whae portion of the building fire might occur, at least one stair or fire es- cape shall remain readily accessible to the occupants. Fire escapes shall be galvanized steel located on the exterior of the building, or enclosed, or horizontal exits, as described in Section 7.100. Every fire escape shall reach to the ground on the sides and near, and not higher than the first story ceiling on street fronts, and shall continue up to and over the roof, and shall be maintained unobstructed, safe and readily ac- cessible to every floor of the build- ing. Fire fighting pipe lines shall be constructed on every fire escape as described in Section 11.910. All types of fire escapes shall be designed to safely sustain a live load of one hundred (100) pounds per square foot of available space. (Note: For Theater exits see Section 13.100 of this Code) In buildings of first-class con- struction having two or more stairways, one of these stairways, if enclosed with fire doors as required for second-class buildings in Sec- tion 7.100 of this Chapter, maybe considered in lieu of a fire escape. Section 7:300. EXIT DOOR. All exit doors in all buildings except dwellings shall open outwards, pro- vided, however, that this require- ment shall not prohibit the use of doors which swing inwards and out- •.vards, nor of sliding or rolling doors in wharves, warehouses, ship- ping rooms and in industrial and xnerckxantile buildings, where condi- tions make such necessary, or the ground floor of stores which do not exceed 5,000 sq. ft. in area. Tne width of opening of exit doors shall Ue as required for stairs and as stipulated in Section 7.110 of this Chapter. Every room having an occupancy of more than seventy-five (75) per- sons shall have at least two i2) doorways four (4) feet in the clear, remote from each other, leading to exits (Note: For theater exits see "Theater;' Chapter 13 of this Code.) Section 7.400. EXIT LIGHTS. In all hotels, rooming houses, dormi- tories, or other buildings two (2) or more stories in height furnish- ing sleeping accommodations for more than Twenty-five (25) persons, ail fire escapes and exits shall be plainly marked by signs having the word "exit" written in letters at least three (3) inches high, which sign shall be illuminated at night, on a separate electric circuit from the building mains. (See 6ection 13.100 of this Code for Theater Exit Lights.` CI~APTER 8 MATERIALS, LOADS AND STRESSES Section 8.110. QUALITY OF MA- TERIALS. All building materials shall be of a quality and standard to meet the requirements of this Code and such tests as [nay be deemed necessary by the Building Inspector. In establishing standards for materials, the Building Inspec- tor shall be guided largely by the standards established by the Amer- ican Society for Testing Materials, and recognized good practice in methods and results, and where no standards are specified in this Code the standards and tests prescribed by (,he American Society for Testing Materials shall apply. 6ection 8.111. ALL TESTS SHALL BE CONDUCTED UNDER THE SUPERVISION AND DIRECTION OF THE BUILDING INSPECTOR. Laboratory tests shall be made at some testing laboratory of recog- nized standing by a competent and disinterested expert acceptable to the Building Inspector. Tests shall be at the expense of the owner or builder. Certified copies of the re- sxxlts of ail tests shall be kept on file in the office of the Building In- spector and shall be open to public inspection. The Building Inspector may, in his discretion, accept certi- fted copies of tests made by reput- able persons in lieu of tests con- ducted under his direction, but in either event the requirements of this Code shall be satisfied. Section 8.112. BRICK. Brick shall be sound, hard burned, or other approved brick of regular shape. Used brick shall be thor- oughly cleaned before re-using. Not more than fifteen (15) percent shall be bats or broken brick. All brick intended for uses where strength is required shall test an average of 3000 Ibs, per square inch, and no sample shall fall below 2000 lbs. per square inch, tested flat (half bricks permissible) and the average ob- tained on at ]east five (5) samples. Section 8.113. SAND. Sand shall be clean coral, beach or crushed rock sand. Section A.114. LIME shall be the standard lime of commerce, or fresh burned quicklime free from deleter- ious matter. Section 8.117. CONCRETE. Port- land Cement concrete shall be so proportioned, mixed and placed that the uses for which it is intended shall be safely satisfied, The mix- ing, handling and placing shall be carried out by persons oP sufficient competency to insure results within the structural requirements of this Code and such additional tests as may be deemed necessary by the Building Inspector. Section 8.118. LUMBER. All lumber used shall be structurally adequate to serve the purposes in- tended within the safety factors re- quired by this Code. No lumber shall be used in any building which is in- fected with dry rot, or termites. Under no circumstances shall any ]umber which is infected with woed- boring insects be used in any build- ing. All such material shall be either disinfected to the satisfaction of the Building Inspector or burned. No such infected lumber shall be transported excepting as may be necessary for disinfection or de- struction. Section 8.119. WROUGHT IRON shall be taken to mean either the true paddled wrought iron or the mild steel usually sold as such with a tensile resistance of not less than 48,000 lbs. per square inch, and shall be fibrous, tough and ductile. Section 8.120. CAST IRON shall be a good fo- rdry mixture produc- ing aclean, tough gray iron. Cast- ings shall be free from cold shuts, blow holes ,and shall conform to the standard test requirements of the "Arbitration Bar" of the American Society for Testing Materials. With the bar supported on twelve (12) inch centers, and loaded in tho middle, the breaking load shall be not less than 2900 lbs. Section 8.121. STEEL. All Rolled Structural Steel shall have an al- timate tensile strength of not less than 64,000 Ibs .per square inch. Rivet Steel shall have an ultimate strength not less than 45,000 lbs. per square inch. Reinforcing Steel for concrete shall meet the require- ments of the current standard spe- cifications of the American Society for Testing Materials for Billet Steel Concrete reinforcing bars. No reinforcing steel produced from re- rolled material shall be used with- out the approval of the Building In- spector. Cold drawn steel wire made froxn open hearth billets or from Bessemer billets may be used as reinforcement in floor :tnd roof slabs and column hoopinF;: and as reinforcement for temperature and shrinkage stresses. It shall have an ultimate strength of nog less than A5,000 lbs. per square inch and shall bend 180° anon its own diameter without fracture. Section 8.200. LOADS, GENER- AL. Buildings and all parts there- of shall be of sufficient strength to support safely their imposed loads, live and dead, in addition to their own proper dead load, provided, however, that no building or part thereof shall be designed for live loads less than those specified in the fallowing sections. Section 8.210. DEAD LOADS. For the purpose of this Code, the fallowing weights shall be taken for the materials listed. Actual tests may be used for these or other materials as provided in this Chap- ter. Brickwork, burned brick _._____..120 lbs. per cu. ft. Brickwork, cement brick _____._..150 lbs. per cu. ft. Concrete, stone and sand ___..150 lbs. per cu. ft. Dense blue lava stone ................170 lbs. per cu. ft. Oak ... _....._____.._.. 50 lbs. per cu. ft. Douglas fir ____._. 35 lbs. per cu. ft. Section 8.220. LIVE LOADS, HU- MAN OCCUPANCY. (ll For rooms of private dwel- lings, hospital rooms and wands, guest rooms in hotels, lodging houses and tenement houses, and for simi- lar occupancies, the minimum live load shall be taken as forty (40) pmmds per square foot uniformly distributed, except that where floors of one and two family dwellings are of monolithic type or of solid or ribbed slabs, the live load may be Lak^_n as thirty (30) pounds per square foot. (2) For floors Por offioe purposes and for rooms with fixed seats, as in churches, school classrooms, read- ing rooms, museums, art galleries and theaters, the minimum live load shall be taken as fifty (50) pounds per square foot uniformly distri- buted. Provisions shall be made, hmvevcr, in designing office floors for a load of 2,000 pounds placed upon any space two and one- half (2?~s) feet square wherever this load upon an otherwise un- loaded floor would produce stresses greater than the fifty (50) pound distributed load. (3) For aisles, corridors, lobbies, public spaces in hotels and public buildings, banquet halls, assembly halls without fixed seats, grand- stands, theater stages, gymnasiums, stairways, fire escapes, or exit pas- sageways, and other spaces where crowds of people are likely to as- semble, the minimum live load shall be taken as 100 pounds per square foot uniformly distributed. The re- quirements shall not apply, however, to such spaces in private dwellings, for which the minimum live load shall be taken as in Paragraph 1 of this Section. Section 8.221. INDUSTRIAL OR COMMERCIAL OCCUPANCY. In designing floors for industrial or commercial purposes, or purposes other than previously mentioned, the live load shall be assumed as the maximum caused by the use which the building or part of the building is to serve. The following loads shall be taken as the minimum loads permissible for the occupancies list- ed, and loads at ]east equal shall be assumed for uses similar in nature to those listed in this Section. Minimum Floors used for Live Load lbs. per sq. fc. Storage purposes, gen- eral 250 Storage purposes, spe- cial 200 Manufacturing, light.... 75 Printing plants ............ 100 Wholesale stores (light merchandise ._____. 100 Retail sales room s (light merchan~ise).. 75 Stables 75 Garages: All types of vehicles 100 Passenger cars only .. 80 Sidewalks: 250 pounds per square foot or 800 pounds concentrated, whichever gives the greater shear. Section 8.222. ROOF LOADS. Roofs having a rise of four (4) inch- es or less per foot of horizontal pro- jection shall be proportioned for a vertical live load oP thirty (30) pounds per square fooC of horizontal projection ,applied to any or all slopes. With a rise of more than four (4) inches and not more than twelve (12) inches per foot, a ver- tical live load of twenty (20) pounds per square foot, on the horizontal projection shall be assumed. If the rise exceeds twelve (12) inches per foot, no vertioal live load need be ssumed, but provision shall be made for a wind force acting normal to the roof surface of twenty (20) pounds Per square foot. Varying slopes shall be considered independ- ently. Section 8.223. A L L O W A N C E POR MOVABLE PARTITION LOADS. Floors in office and pub- lic buildings, and in other buildings sub.{act to shifting of partitions without reference to arrangement oY floor beams or girders shall be de- signed to support, in addition to other loads, a single partition of the type used in the building, placed in any possible position. Section 8.224. REDUCTIONS IN LIVE LOADS. Except in buildings for storage purposes, the following reductions in assumed total floor live loads are permissible in design- ing all columns, piers or walls, foun- dations, trusses, and girders. P.eduction oY Total Live hood Carried: Per Cent Carrying one floor 0 Carrying two floors ___.....-._. ]0 Currying three floors -_.__.-.._ 10 Carrying Your floors .._.....__. 30 L"arrying flue flom~s _- __._. 40 Carrying six floors .. _.._.___. 45 Carrying seven floors or more 50 For determining the area of foot- ings the full dead loads plus the live loads, with reduction figures as Uermitted above. shall be taken, axcept that in buildings for human occupancy, ]ietod horeinbefore, a ihrther rodnctimx oP one~half (x/a) the live load as permitted above may he resod. Section 8.226. LIVE LOADS' TO BE POS'fNa. The live loads for which each floor, or dilTeriug parts thereof, of a omumercial or indns- triai building ot]t er than an offim or similar buihting is designed shall be certified by the Building llxspector and shall be conapimt- ously posted ht that part of caclx story where they apply, using dur- able metal signs. Lt shall bo u~- lawful for any person W occupy a Auilding mail a certificate uP oc- cupancy has been issued, and no certilcate 'shall he issued mail the load rating regntred by Clue Sec- tion has been pasted. (Soe Sec- tion 1.130 of this Code) 6oction 8.230. WiNU PRliS- SURES. For tho Hurposoa of de- sign tha wind pressure upon all vertical place surfaces of all build- ings and stnmtures shall be taken at not leas than ten (10) pounds per square foot Yor those pm~timts less than forty (40) feet abova Ground and at not less than twenty (20) pounds per square foot [or those portions more tha¢ Yorty (40) feet above ground. The wind pressure upon sprinkler tanks, sky signs, or apon similar exposed strnetures and their sup- ports shall be taken at not less than thirty (30) pounds per square foot oY pla.ne surface acting in any directimr. In calculating the wind pressure ou circular tasks or stacks this pressure shall be assumed to act on six-tenths (8/10) of the pro- jetted aroa. Whe¢ it shall appear that a hnilding m' structure will be ex- posed to Lhe full force of the wind throughout its en the height and width, the pressure upon ali ver- tical surfaces thus exposed shall be taken at not less than twenty l20) pounds per square Loot. Section 8.301. A L L O W A B L E ~i'ORI{ING STRESSES, GEN- 191tAL RE~i ULHElIlENTS- All members shall be so framed, an- chored.tied and braced together as (o develop the maximum strength and rigidity consistent with the purposes for which Yhey may be used or to which they are likely to be subjected, and the stresses here- inafter recommended are based ou the axes mptio¢ that iho details and Connections nsod are Yully as strop R' as Che members connected. Workmanship in Cabricatimt, pre potation and iustallatiou of ma- terial shall conYm~m throughout to good engineeri¢g practice. Section 8.302. W O R K I N G STRESSES IN REINFORCED CONCRETE. 1. Concrete in reinforced con- crete construction, when mixed in the following proportions, stated by volume, shall be assumed to de- velop a laboratory cylinder com- pressive strength at 28 days as follows: TABLE 1 ASSUMED STRENGTH OF CONCRETE MIXTURE Plastic Mass Concrete (Slump 1 to 3 inches) Approximate mix: volume of Port- land cement to sum of separate volumes of fine and coarse aggre- gate. Water-cement ra- tio U. S. gals.l Assumed ulti- per 94-1b. sack of mate strength cement. at 28 days. Lbs./in.° 1 - 6 .........._.......____ .... ............._..__._..__.........-.T/a 2,000 1 - 5 6t/x 2,600 1 - 4 .............................. ... .................5Ya 3.000 Moderately Wet Concrete (Slump 6 to 8 inches) 1 - 6 _._- .___._. ......_ _..-..8 1,600 1 - 5 7'/a 2,000 1 - 3°/a._._.._...__..__._.__... ____._.__....._...._............6i/a 2,500 1 - 2'h.___...___._ ............ .__....______._.__...___._5ria 3,000 Very Wet Concrete (Slump 10 inches or more) 1 - 5 ....._______.._ .................. ..._....."'__..........--.8 1.600 1 - 4 _ _... ' -' ' - .--- T/a 2,000 1 - 3'/aa-._._........_______......_........ ._'__._ .....................e'h 2,500 1 - 2~/z .__........____......-.5'/a 3,000 to In no case shall concrete for any assumed strength be placed with a water-cement ratio exceeding that shown. Where the aggregates are such that the mixes shown do not produce proper workability with the given water-cement ratios, Eire mixes shall be changed, but not the water-cement ratios. The graded sizes oP the combined aggregate shall be such that when separated on a No. 4 standard sieve the weight retaining shall not be less than one-half or more than two-thirds of the total The fine aggregate may be crusher sand, and/or a mixture of coral sand and crusher sand. 2. If and when it is shown by evi- dence of tests made by competent authorities satisfactory to the Building Inspector that concrete of a higher strength than that speci- fied in the preceding paragraph will be used and that competent field control of mixing and placing is assured, or that concrete of less strength will be employed, the stresses shall be proportionately modified, provided that in no case shall a strength of more than 3,000 pounds per square inch be assumed. 3. The working unit stress in steel reinforcement shall not exceed 16,000 pounds per square inch, pro- vided that this stress may be in- creased to 18,000 pounds per square inch when certificate oI test is furnished the building In- spector that the material conforms to the American Society for Test- ing Materials Standard Speciflca- tlons far Billet 6tee1 Concrete Reinforcement Bars, serial designa- tion A 15-14, or for Rail Steel Concrete Reinforcement Bars, seri- al designation A 16-14. The tensile stress in cold drawn steel wire meeting the tentative specifications A 82-21T of the American Society for Testing Materials shall not ex- ceed 18,000 pounds per square inch. Goncxrote shall not be assumed to resist direct tensional stress. Except as otherwise specifically provided in this Code, the assumed formulas and specifications of the IuLest report of the Joint Commit- tee on Standard Specifications for Concrete and Reinforced Concrete shall not be exceeded in calculating the strength of slabs, beams, columns, and other elements of re- inforced concrete structures, and designs shall conform thereto, which are, in part, as follows: DIRECT STRESS IN CONCRETE: Direet Compression (a) Columns whose length does not exceed 40 R ._.........__.._0.201"c (D With •spirals, varies with amount of longitudinal reinforce- rneut. !b) Piers and pedestals ....__.:-.0.25f'c Compression in Extreme Fiber la) Extreme fiber stress in flex- xn'e _._..__ ______......_0.40f'c [b) Extreme fiber stress adjac- ent to supports of continuous beams 0.45f'c SHEARING STRESS IN CONCRETE Lon.;itudinal Bars Without Special Anchorage la) Bums without web reinforce- ment _.... ....__ ____....._D.02f'c <b) Beams with stirrups ox kept- up bars, or combination of the two ....___ ____....__ _._. O.O6Pc Longitndinal Bars Raving Special Anchorage (a) Beams without web reinforce- ment ... _._.. _ _...________ 0.03f'c [h) Beams with stirrups or kept- up bars, or combination of the Lc~o _..... _ ____._ _____._0.12f'c Fiat Slabs (a) Shear at distance from Capital or dropped panel _........__-.._..0.03f'c Footings ~a) hongitudinal bars without spe- cial znchorage _-__._.__.__. 0.02f'c (b) Iamgitudinal bars having spe- cial anchorage 0.03f'c Bond Between Concrete and Rein- forcement (a) Beams and s l a bs, p l a i n bars ._..._._.___._.__.__ _._____..-0.04f'c (b) Beams and slabs, deformed bars _._.______.._......__-____--O.O5f'c (c) Footings, plain bars, o n e waY .__ __ -__-____.__._.....0.04f'c [d) Footing, deformed bars._.0.05f'c (e) Footings, bars two ways, (G or (cU reduced by 25%. hx the foregoing, Fc is the uiti- nxate compressive strength oY con- crete at twenty-eight (28) days Cased on the Standard Laboratory tests as specified by the American Society Pox Testing Materials. Section 8.303. CAST IRON. Compressive stresses in hollow cast iron shall not exceed urines determined by the formula. P/A equals 9,000-40L/r in which Y/A equals compression in Founds per sq. in., L equals length of the column In inches, and r ecuaU minimum radius of gyration of the column. The maximum allowable ratio of L to r shall r.ot exceed 90, except that when allowable working etressos romputed by the above formula are reduced one-third (1/3) the ratio of L to r may be increased but shall not exceed 120. Cast iron columns shall not be used in any case where the load is so eccentric as to cause tension fn the cast iron, nor shall they b2 used for parts of the structural frame oP building which are rc- qulred to resist stress due tc wind. Tensaw stresses in the extreme fiCre cast iron linteh or else- where, esccpG in co;wnns, shall not exceed 3,000 pounds per square inch. The material and workmanship of cast xrcn columns shall be equal in all respects to that de- scribed in the American Society for Testing Materials Standard Specifications fox Cast Iron Pipe and Special Castings, serial desig- nation A44-04. All columns rest- ing on or supporting other columns shall have their ends machine faced to a plane sux•tace perpendicular to the axis. Section 8.304 WORKING STRESS- ES IN STRUCTUAL S T E E L SHAPES. For steel acceptable to the Build- ing Inspector, but of which the ori- gin and physical characteristics are not definitely determined, the maximum working stresses shall not exceed those given in column (a) of the following table: TABLE II. MAXIMUM WORKING STRESSES IN STRUCTURAL STEEL Direct axial tension on net section ..._.._. Direct axial compression, maximum for (a) (b) Acceptable Steel Standard Steel Lbs./in. Lbs./in:" ....................16,000 18,000 short column ...........__.____________________ _______.______________.._ _12,500 14,000 Compression in columns .._..._ _ _ _.__ ____...__.16,000- GOLjr 18,000-70Ljr Fiber stress in flexture, in tension ar in com- pression when the unsupported length (1) is not more than 15 times the breadth (b)__.._.. .16,000 18,000 Compressive fiber stress in flextures for values Ljs between 16 and 40 _ ............... ......__.10,600-240E/s 22,000-270L,~s F:her stress in pins _.._....... _ _._...... _____ 24,000 27,000 Fearing on plane faced or rolled surfaces...___..__ .24,000 27,000 Shear in gross section of webs of girders and rolled shapos in which (d) the unsupported depth between flanges or the distance be- Lween stiffeners, if less, divided by (t) (the thickness of web) does not exceed 43__-__.... .10,700 12,000 Shear when d/t ex,:eeds 43 ______._._..____ 13,300- 62d/t 15,000-70d/t Shear in power-driven rivets or in pins ___.__.___ 12,000 13,500 Shear in hand-driven rivets or in rough bolts._.___ . 9,000 10,000 Bearing neon power-driven rivets or in pins sub- jected to single shear on one side of bearing in questior, ..____. _. _.___......_______........___.._.._..__. .24,000 24,000 Bearing upon power-driven rivets or in pins when the bearing meta] lies between the planes of shear of opposite character immediately adjacent ...__.._.._____...._____.___.__._._..__...._______ 30,000 30.000 Bearing upon hand driven rivets or on rough bolts subjected to single shear on one side of the bearing in question .._.._._.....____...____...._._.__...__ 16,000 16.000 Bearing upon hand-driven rivets or on rough bolts when the bearing metal lis between two planes of shear of opposite character im~- medxately adjacent Compression stresses in columns, comPUted by the formulas for column design, may not exceed in any case the maximum for direct axial compression in short columns, L equals length of column; r equals least radius of gyration. 3. For main compression members, the ratio L/r shall not exceed one hundred and twenty (120) and for bracing, struts and similar mem- bers two hundred (200). Com- pression flanges of beams and girders shall not exceed in length between '9ateral supports" forty f90) times their width. By the term "lateral supports" is meant points where definite resistance to lateral deflection is provided of sufficient strength to prevent buck- ing. Combined stress due to flexure and axial stress shall not exceed that allowed for Flexure. The axial strass alone. if compression shall not exceed that allowed in columns. (See tables) 20.000 20,000 4. For stresses either direct or flexural produced by wind loads or by a combination of wind loads and dead and live loads, the work- ing stresses allowed in paragraphs (ll and (2) may be increased by twenty-flue B5) per cent, provided fire resulting sections are not less than those required for the dead a,nd live loads alone. Section 8.305. W O R K I N G STRESSES IN WOOD MEMBERS: 1. All wooden structural members shall be of sufficient size to carry the load safely without exceeding the allowable wozking stress of the material specified in the following table. The strength of such mem- bers shall be determined from actual dimensions of the pieces and not from nominal dimensions. 2. The stress due to dead and live loads acting singly or in combina- tion, without wind load, shall not exceed the allowable stress speci- fied in the following table. For 11 stresses produced by wind loads or by a combination of wind loads and dead and live loads the work- ing stresses allowed below may be increased by fifty (60) per cent, provided the resulting sections are not less than those required for dead and live loads alone. 3. Stress in corxtpression perpendi- cular to the grain may be increased by fifty l50) per Dent above that specified in the following table in the case of joist supported on a ribbon board and spiked to the studding rather than resting upon or in masonry. 4. The restrictions and limitations of the two preceding paragraphs apply to all timber structures in which the lumber is in a dry loca- tion and not exposed to the weather. Timbers exposed to the weather shall be designed on a basis of working stresses twenty- five (25) per cent lower than those recommended in the follow- ing table: aY different soils shall be as da tcrmined by Lhe Building hrspector, hut. in Lho absence of Tests shall nr,t exceed Lhe followng values: Soft sciL _..____.. 1 ton firer sq. fl. Firm clay, hno Baud, or coarse compacted black sand _ 3 Lm~s per sq. ft. Grave; and biucK nand _.____.._ 4 taus per sq. ". L. Solid coru.l (de- pendiug on clxaracterletics m' Lestl ..---_ 4 xous Der sq. ft. Solid cm'al (des p ending nn characteristics cr test) _._._ .. 3-16 tons per sq. ft. Solid rock .. __15-70 tone per sq. 1't. CdiAPTER 9 CONSTRUCTION Section 9.100. WOliK1bIANSHIP. 1*h rong7tonL Uxis Oodo Lhu values established for the strengths of structures, meIDods m' materials, WORKING STRESSES FOR TIMBER m x n a a ~ w° wo Ul av° n' [ham w ~ G' mua P. o m~ '6 om _.,y m ~5K w ~•~ ~ R ,'y w m ~ O ro as ~ 'S y O .. 0 w1Dx u m 7 ~ N m ° ~ i 9ti a m K ~ b 9m Mb ry ~'~ ° ~ s G+y ow w woF ~ m °~a Cm ~ .. r ao G `" m N m in ~ " o L bs.j in.' Lbs./ in! Lbs./in: Lbs./in: Lbs./in: 1. Douglas flr (Western Wash- ington and Oregon) _.__._ _ 1,600 90 345 1,175 1,600,000 2 . Douglar fir (WesternWash- ington and Oregon) dense _.1,750 105 380 1,290 1,60Q000 3. Oak, commercial red and white _.__._...._____-___._ ............. ...1,400 125 500 1,000 1,500,000 4 Pine, white sugar, west- ern white, western yellow_ .. 900 85 250 750 1,000,000 5. Redwood ......_._. ___.._____... ...1,200 70 250 1,000 1,200,000 Mininwm distance, center to ce~~er2 feet Maximum unit load, at the halt --5c0 lbs./'srl. inch. -fuximum toLUl load-20 tons. Any pile twosty (20) feet or xn ore in length shalt be not less than twelve (12) inches at the butt, Lor Uxe proceeding loud ullu~a- avccs. The safe sustaining power of a pile not driven Lo refusal shall be, in the absence oT test, computed by the following formula: L= 2Wi1/P}I For drop hammers. L~2WH/P}I Fox steam hammers. ID= allowable load in tong Lm¢xi- mum 20 tons). W= .the weight of the hammer in tons. H=the fall of the hammer in feet (maximum 15 feet). PJthc average penetration in inches for the last 5 blows. Sec~iou 9 322. L' O i'V Olt H7 T i.. I'ILSS. In tha abaen ce oP acln a.I test, the followh~g shall be r.oemed a guide for acceptable design: (;oumete, L,000 pmmds crush%ng sllrngth at 28 dups. Not mere than one (1) splice to a pile. When driven Lo refusal, maxi- mum unit load equals 500 lbs. per sq. inch on Lhe concrete- Clcar space between heads of piles, 16 inches. fteinlorcmuont shall be not less than two (2) per cent lonfdtu dinttl wifll beeping not less than threo- eighths (~i~) inch round spaced not more than sire (6) inches cn centers. 'I'bo average dia~m star oC tllo pile not lass than twelve (12) inches, and minimum fliam star six (G) inches. The length shall not exceed sixty {60) diameters in fairly firm material, and shall be con- sidered as a column in very soft material overlying firm coral or rock. SAFE STRESSES FOR SQUARE AND RECTANGULAR WOODEN COLUMN Ratio of L ength to Least Dim ension 11 or Species Grade less 14 17 20 23 26 20 32 35 40 50 Lbs/ Lb/ Lb/ Lb/ Lb% Lb/ Lb/ Lb/ Lb/ Lb/ Lbi 2 2 2 2 2 2 2 2 2 2 2 loci- inch inch inch inch inch inch inch inch inch inch Douglas Fir Coast type dexvse._...Select ....... ..__. 1,285 1,222 1,147 1,023 83ll 649 521 428 358 274 175 Meech ....... ..__. 1,060 1,026 935 913 803) Douglas Fir Coast type ...__...__Select ._._ _...... 1,175 1,127 1,070 975 826) 649) 521 428 358 274 175 Meech _.... _...... 886 861 837 796 734) 640) Oak-Red and White .._.._.._.-Select ....._ ._... 1,000 967 927 860 755 608) 489 401 336 257 164 Common . _.._. 800 783 762 728 674 595) Pine-- white -_.-_._ ._._._._._..._.Select ...... ..._.. 750 71II 680 617 518) 405 326 268 224 171 110 Sugar ........ ~ ............ Common . ....... 600 583 564 532 481) Pine- Southern _ __..._.. _._.Select ...._ __... 1,]75 1,127 1,070 975 826 649) 521 428 358 274 175 Yellow ..._ ..._.._... Meech ..._. __.... 88G 861 837 796 734 640) NOTE: See 6ection 9.703 for Column for mula. 5. ~VOrking stresses in compression parallel to era.in for columns shall not exceed cnose in the table for the respective species and ratio of unsupported length to ]cast dimension. The ratio of unsup- ported length of clumps to least dimension shall not exceed fifty (50). 5octimx 5310. FACTOR OF S,~FhIT Y. When over nm~ device, matct~al or Construction is pro- Pcsel which is not covered by tha mininnnn working sues ses in this rode or not provided for in the sPt`t'itirnlluns of the Amerioan So- cir_ty for TesL9ng Materials, the B ni'd ing Iu space or shalh after dC term+natimr of the siren gLh of the Name_ fiv the Yadnr oY safety which shall b, apPlicahlre thereto. Such foster sh;r1L bo consistent wish Pao- tcr~ for similar malaria La or nso5 as stipnla let in this Coil e. Section 8.400 BF:IRINC) VALUL OT` SOILS The safe bearing value p r r s u xn e s good worlcmaoehip ihruughont, and no such structure, m eL'.rod or matecia] shall bo deemed Lo have cmnplicd with this Cade unless the standards coxmnon to tba art or science of coush~uckimr which are commonly applied by competent men and r•ecogniael by the bniklirg industry as good wm~k- mnnsbip shall obtain throughon t. Soctimt 9.200. F7%CAVATIONS. Fxuavntions Tor Ponnlotions shall be of eurh depth 'sod characim• as to insure the bearing values pea scribed by this Coda {See Section ]0.400 of this Code for Lateral Support.) Section 9..",]0. FOOTINGS. Post- ings shall bo so Proportioned that the load fs eveuLy diHtribntel there- mr amt withmrC unresisted orcen- 1:Icitles. Soetimt 9.820. WOOD I'ILP POTiP:Af. TION. hx the absence of uctnal Lest, wood Piles shalt cou- fm~m to the following: The requirements for proper coring, casting and mixi*,g oY con- crete sti'pnlaf ed elsewi~.ore in this Code shttl] be complied with. The sn'eugth of concrete piles nPmr delving shall he cmnpnted by fibs sa.rne formulae as stipulated in ills preeeding section for wood piles, but shall not exceed thirty (80) tons total load. Section 9J;30. ]L E T A 1 N I N C WALLS. For walls designed to retain embau]cxn en ts, or other uses. Lho stability shall be rletennined by either Lhe Rankine, Coulomb or Caitt formulae, LuL in no case shall the base of plain manum ;/ walla, witboat snreh arg~e loads, bo less than ono-four4t (yeJ the height. Secti mt 9.840. AliEAWAYS ANU SLllLWALK OI'ENINC,S. Thers shall be no permanent opening oC any sit ewalk, except ii be covered with metal sidewalk trap doors, the outer edge of which door shall not be closer t]?au two (2) feet of 12 the outside edge of file sidewalk mtrb. All such openings in side- walks shall have metal elvers flash with the walk, wiW upper surface roughened. Every such door shall be provided with met al guards for the protection of the public when open. AIL parts of sidewalks, in- cluding illuminating file or other structural parts, shall be capable of suetaiuing the loads hereinbeforo stipulated far the sidewalks. (See Section 8.221 of this Code.) Sectimt 0.410. SOLID BRICK WALLS. 4jlIALITY O F M A- TERIALS. Brick and sand-lime brick used Tor bearing walls or piers shall be of quaifLy at Least equal to the "medium brick" de- scribed by the Standard Specifica- tions for Building Brick of the American Society for Testing Ma- terials, except that when the aver- age compressive atrettb'th oC brick grading "soft" by the absorption test ie more thsn 2,b00 pounds Uer square in c)t, the requirements as to absorption may be waited. Whoa used for non-bearing pur- poses and not exposed to the weather, brick may be of quality not inferior in say respect to the "soft" brick described in Lhe above specifications. The average tom Pressi sa strength of concrete brick 29 d;tye after being mamlTactnrod, or when delivered on the job, shall be not less Lhan 1.600 ponuds per square inch of gross cross-sections! area tested in Uto position as laid in the wall, and the compressive sLrengU] of any individns] brick thus tested shall be not less than 1,000 Pounds per square inch. All oemont_s and limes used i^ mortar shall conform to Lhe re- quirements of the e!andard speci- fications for These materials issued by the American Society for Tnst- htg Materials. Saud used ii mortar shall be clean crusher or beach scud and free Lrom alilmal or vegetable maL- tEC. , Section 0.411. T.ATI9RAL SUP- PORT. Solid brick walls shun be supported at right angles [o the wall fsce at inLervsls not exceeding eighteen (1H) times the wall thick- ness iu ttte top story or twenty (20) times the wall thickness elsewhm~e. Such lateral support may be ob- tained by moss walls, piers or buttresses, when the limiting dis- tance is measured horizonf ally, or by floors when the limiting distance ie measured vertically. Sufficient bonding or a.n ch orage shall bo pro- vided between the wall and the supports to resist the assumed wind force, acting in alt outward direction. Piers or buttresses re- lied upon for lateral support shall have suffi rient strength and sta- hiliiy to transfer the wind force, eating in either direction to tits gronuil. When ws]ls n.re depend wit upon floors for their lateral sup port, provisions shall be made in the building to transfer the lateral fore.es resisted by all floors to the ground. Section 0.412. WORK 1 N G S'PI{EGSES. The maximum allow- able compressive stresses in brick mssonry due to combined live and dead loads shall not exceed the tOIIOWIDg ]lmlt0: BILICK MASONRY STRESSES Maximum unit worlc- (Continued from Page 30) ing strews( pounds per square inch) ti C ~ d G t. q^ ro V ~ U C ~ ~ 'rte n m 9 ~, m w ^ S 6 ~ J .7 .. % o Brick (clay) me- atnnt grade_..__. _ I7o l30 90 Sand-lime brick __ _ 170 130 !10 Concrete brick ...-.... 170 130 70 Where the etYects oY ecceuiric loading and lateral forces are fully analyzed and allowance made for [hem in the design, or under local cmn;eulrated loads applied Lo a limited proportion of the total area of the wall, the working stresses in this table may be increased by fifty (60 %) per cent. Section 9.413. THICKNESS Oh` ESThl{fOR WALLS O'I' H P R T IL A N : N SKELETON CON- STRUCTION. The thickness of solid brick bearing walls shall be eu[iicient at aL] points to keep the combined stresses due to live and dead loads for which Ute building i5 designed within the limits Pre- scribed by Section 9.412. The minimum Lhickuess for solid brick exterior bearhtg or party walls shall be 12 inches for the u-Permost thirty-five (35) feet oY Uteir height, and shall be increased tour (4) inches for each successive fifteen (16) feet or fraction thereoY measured downward from the top of Lhe wall; except Umt Lhe top story exterior bearing wall of a building' not exceeding three l3) stories or forty (40) Teat in height, or the wa!1 of a mte-sLOry commer- cial or iuduatrial building may be eight (&) lushes thick, provided that such 3inch wall does not ex- ceed twelve (12) feeC unsupported height and that Lhe roof beams are horizontu-.: and except that exterior solid hrh k bearing walls of one call Ltvo family dwellings may be eight (h) inches Utirk when not mm~e than thirty (301 feeC in height When gable constriction is used for such dwellings, an ad- ditional five (5) Yoet is permitted to the peak of Lhe gable. Where solid brick exterior bear- ing m~ party walls are stiffened aL distances not Kreater Lhaat twelve (12) Peet apart by cross walls, or by 1^tOTn31 OP exim'nal Offwts et' rotunts, at least two (2) feet deep, they may be twelve (12) inches Chick for the nPperm osL seventy the top of the wall, and shall be (iU) feet, measured downward front increased four (4) inches thickness Fm' each successive seventy (70) feet or Pra ctiou thereoY, The minimum thiclvtess of solid brick exterior nonbearing walls shall he~twelve (1`L) inches for Lbe uppermost seventy (70) Ceet of thou height, attd shall be increased four (4) inches Tor each suecessivo thirty-five (36) feet or Craotimt thereof, measured downward from the top oC the wall, except that the top story wall of a building not oxceoding three stories or forty (40) feet in height, or the wall of a one (1) story commercial or in- duslrial building may be eight (3) inches thick provided that such eight (8) inch wall does not exceed twelve (12) feet unsupported height, and Utat the roof beams are horizmttaL; and except that 6olld bC'ick 110ll-b Eating Walls OY Otle and two-family dwellings may be eight (3) inches in thickness when not more Lhan ffiirty (30) feet in }teight. When gable construction is need Yor such dwellings an addi- tional five (5) feet is permitted fo the peak oP the gable. Section 9.414. BOND. In all brick walls at least every sixth coarse ou both silos of Lhe wall shall be a header course or there shall be at least one fall length header in every seventy-two (72) agnate Inches oY Hach wall surCacE. ht walls more than twelve (12) inches thick the inner joints of headEr 00nTSea aha^ be COV P,red with another header course which shall break joints with the coarse below. Where tinning bond is used, every sixth course on each Yace shall be bonded into the back- ing by cutting the face brick course and iein.g diagonal headers behind it or by using a split brick. SectSon 9.416. P1ERS. The un- supported height nC brick piers shat] not Escecd ten (10) times their ]east dimension. Section 9.410. UFIASES AND IU.CESSES. There sllsll be no chases in b-iamb walls or within Ltle required area oC ally pier, and no chase in any wall or pier shall be deeper than one-third 1/3 the ws~l thickness. No horizon Lal chase shall exceed five (51 feet in leng'.h, nor shall the horiaontal projection of anY diagonal chase exceed four (4) teat. Recesses for stairways or eleva- tors lacy be ]eft iu walls, but in no rise shall the walls st such points be lose than Ute required Lhickueas oC walls oC Ute &nu~th story above the ground floor unless reinforced by additimtal Piers, by steel or reinforced concrete girders, Or Steel or I'eillfm'Ced EmtCI'EIE columns and girders, semlrely an- chored to the walls on each side of such recesses. Recesses fm' alcoves and similar purposes shall have not. less than eight (S] inohes of material at the back. Such re- cesses shall bo not more than eig;h[ (S) feet in width arld shall he arched ovm• or spanned with lintels. The agk'l'E.giti0 area. Of TEC,Eaaea and chases in any wall shall not exceed one~YOUrth Lhe whole area oY the face of the wall in any stm't'. No chases or recesses shall be pertnitl.ed in fire m' fire division walls that will reduce the thide- ness below the minimum specified in this Code. (Sectimts 9.470 to 9.473 oP this Code.) Openings for doors attd windows shall have well-buttresses, arches or lintels of masonrg or of metal with bearing at each end oY not less than Ymtr (4) inehos on [he wall. Section 9.420. HOLLOW TILE WALLS. (1) HOLf.OW CLAY TiT.E used for exferiar bearing walls or piers or for party walls shall be of qna]- itY at least equal to the "medium clase'• as prescribed by the Tenta- tive Specifications fm' Holln~,v Burned-Clay Load-Rearing ~V a 11 Tile of the American Society for Testing Materials. When used for non-bearing pur- poses and not exposed to the weather, hollow file may be of GualiLy not iu fe~ri or ill any respect to the "sell class" described in ^te above 5Peciflea.tions. (2) CONCI{ETN: BLOCK OR OONC,RETp.' TILN;S. The strength regniremen [s Tor compression 23 lave after to anufacGtre of conr•.rete block and concrete file shall be classified ae Load Bearing a,nd Non- Load Rearing and shall have the following breaking 5trengLh: ComprP.aaive 9L1'eltgth. lb. per sq. in. of gross cross~soction al ;tree as laid in Lhc wall. m r/I 4 ++ o'er c~ u.a Naxne of Classification ~ F ~ o '~ F 6 ~ > d q ti' `c ~ Load bearing block or file _..______..._..____. 700 600 Non-load bearing block OT the . .. ....... ......_.. 250 200 Tests no concrete block shall be conducted in accordance with the Standard Specification of the American Cmtcrete Institute. (3) BRICK. Brick for hollow walls shall conform to reguirements oP Section 9.410 of this Chapter. (4) MORTAR. ,Either Port;and cement mortar as defined iu Chap- ter 2 or cement-lime mortar shall be used for walls of hollow unit construction or hollow walls of brick. Section 9.421. LATERAL SUP- PORT FOH HOLLOW TILE. !halls of hollow file or of concrete block or tile, and all hollow walla oY brick 13 shall be supported at right angles to the wall face at intervals not exceeding sixteen (16) times the wall thickness eleswhere. Such lateral support may be in the form oP cross walla, piers, or buttresses when the limiting distance is hori- zontal, or by floors when the limit- ing distance is vertical Sufficient bonding or anchorage shall be pro- vided between the wall and the attpporta to resist the deauttted wind Tmne acting in an outward direction. Piers or buttresses re- lied upon for lateral support shall have sufficient strength and s[a- bflity to transmit the wind force, ar,ting in either direction, to the ground. When walls are depend- ent on floors for their lateral sup- port, provision shall be made in the building to transfer the lateral farce resisted by all floors to the ground. Soctlon 9.422. A9 O R K I N G ST11L<'SSES FOR HOLLOW TILE. The maximum allowable compres- sive stresses in masonry of hollow tile, concrete block or concrete tile, or hollow walls of brick, due to combined live and dead loads, shall not exceed eighty (30) pounds Per square inch of gross sec[imtal area, when laid with Yortland cement mortar, and seventy (70) pounds per square inch of gross sectional area when laid with cement-lime mortar. (See Chapter 2 of this Code for definition of Cement- Lime Mortar) Seotion 9.4'23. THICKNESS OF HOLLOW TILE E X T E R I O R WALLS. OTHER THAN SKELl9- TON CONSTRUCTION. Walls' oY hollow tile, concrete block or tile, or hollow walls of brick shall tier exceed fifty (50) feet in height oboes the top of foun~ation vrn76. The thickness of walls of the above materials and types shall be sufhoient at aFl paints to keep ffie stresses due to combined live and dead loads for which the building is designed within the limits pre- scr;bed by Section 9.422 oP this Chapter. The tninimnm thickness of ex- terior walls oY hollow tile, or cmt- crete block or tlle, or of hollow- wall construction shall be twelve (12) inches for the uppermost thirty-five (35) feet of their height, and at least sixteen (16) inches for the remaining lower portion; ex- cept that the top story wall of a building not exceeding three (31 stories or forty (40) Peet in height, or the wall of a one-story commer- rial or industrial building, map be eight f3) inches thick, provided that the roof beame are horiontal and that a concrete beam, rein- forced with lives-fmtrthe (%) Per teat of steel, be placed continuous- ly around the top of such walls at the lino oY the roof supporting mem- bers; and except that exterior walls oY one and two-family dwellings may be eight (8) inches thick fur the uppermost twenty (20) feet. \Vhen gable construction is used Ym' such dwellings-au additional fire (o) feet is permitted to the peak of the gable. Where walls are stiffened at dis- tances not greater Lhan twelve (121 feet, by cross walls or by infernal or external rehtens at ]east two (2) feet deep, the thickness may bo twelve (12) inches throughout, except that the top story, or Yor one and two-family dwellings the uppermost twenty (20) feet, may be eight (8l inches as previously provided- (For interior wall re- ~ptirements see Sections 9.470 to 9.473. and 9.475 and 9.47G of this Chapter. Sectimt 9.424. BOND FOR HOL- r.oAV TILE WALLS- Whm-e two or more hollow units are used to make up the thickness of a wall. the inner and outer conrees shall be bonded at veriicnl intervals not eXeeedlxlg three (3) COllTSea by la.Pping nt least one ill coil com- pletely over a cell oP the unit be- low. Section 9.425. BEAM SIIPYORT9 FOR HOLLOW T1hE WALLS. Suitable provision shall be made at each line of flour beams in hollow walls or walls of hollow units to shut off the spaces above from those below. and to ensure good bearing for beame and miiform dis- tribution of loads. Section 9.426. PIERS FOR HOI~ LOW TILE WALLS. Hollow file or hollow concrete block or ti;e shall not be used Tor isolated piers unless solidly filled with concrete. The unsupported height oY such piers shall not exoeod te^ (10) times their least horizontal dinten- alOYl. Sectimt 9.427. CHASES AND RE- CESSES I'OR HULLOW TILL WALLS. Chases and recesses in walla of hollow tile, hollow con- crete block or tile, or in hollow walls of brick shall not psceed in extent those Permitted for solid brick walla under the same con- ditions. Chases and recesses shall not be cut in walls of Cho above types, but may be built, in. No chasee or recesses shall be ner- mitted in flee walls that will re- duce the thickness below the mini- mum specified iu this Code. Openings Tor doors and windows shall have wall-buttressed arches or lintels oT masonry or metal with bearing at each end of not less than four (4) inches on the wall. On the in-;ids of openings less than flue (6) feet wide, in which [he thickness of arches and lintels fa loss than that of the wall sup- ported, timber maY be used, which will rest at each end not mm's than two (`l) inches mt the wall and be chamfered or mil to serve as arch centers. Section 9.480. C O N C R E T E WALLS, MATERIALS. Monolithic emuaete construction emiaining not more than two-tenths (2/10) pY one (1) Per cent of reinforce- ment shall be classed as plain con- C1'etP.. Materials for bearing walls and piers of plain cmmrete shall be mixed fu propm'tlons oP one (1) part oY Portland cement to not more than three (3) parts oY sand and five (5) Porte of coarse aggre- gate, by volume, or a mixture oY flue and coarse ag6regate giving an equivalent strength and density. Coarse aggregate shall ponsis[ oY crushed stmte or gravel, eighty'- five (85) Per cent of which Ss i'e- tainod on a No. 4 screen, and shall be graded in size from small to large particles. The particles shall be clean, hard, durable, and tree Yrom deletrious material. Cement for plain concrete shall conform to the requirements oY the Standard 5Peciflcalions and Tests for Pm'tland Comeni ~f the Amm'- ican 6ociety for 'Pasting Materials. Fine aggregate shall consist of sand, stone screenings or other similar inert materials, or a com- bination thereof, having clean, hard, strong, durable uncoated grains and free from injurious amounts of dust, lumps, sett or flaky part[cles, organic matter, loam or other deleterious sub- stances; and shall fangs from Line Ln coarse. Not less than ninety- five (96) per cent shall pass a No. 4 sieve, and noC more than thirty (30) per cunt shall pose a No. 5 sieve, when tested according W the standard practice Prescribed by tits American Society Yor Teeting Ma~ lariats. Section 9.431. LATERAL SUP- PORT, CONCRETE \VALLS. Plain concrete walls shall be supported at right angles Lo the wall trace at intervals of not exceeding twenty (20) times the wall thickness. Such lateral sn Ppnrt ma.y be in the Toren of cross walls, piers, or buttresses when the limiting spacing is hori- zontal, or by floors when the limll- ing distance Ss vertical. Sufficient bonding or anchorage shall be Fro- vided between the wall and the supports to resist the assumed wind force acting in an ounrm'd direction. Piers or buttresses, re~ lied upon for lateral su Pport, shall have sufficient strength mtd stm bitlty to U•ansYer the wind force, acting in either direction, to the ground. When walls are dependent upon floors for their lateral sup- port, provision shall be made in the building to G'ansfer the lateral force resisted by all floors to the ground. Section 9.432- W O R K I N G STRIvSSEB, CONCRb:TE WALLS. The maximum allowable sh'esses in masonry oT plain concrete oP the Propm-ti mis specified in Soc lion 'J~430 of this' Chapter as a minimum due to combined dead and live loads shall not exceed four hundred (400) pomtds per square inch in compression, thirty five (35) pounds per square inch in tension m' diagonal tension; or ninety (90) pounds per square inch in punching shear. When plain concrete of greater strength is used the foregoing stresses may be increased twenty (20) per cent of the ultimate compressive strength Por concrete in com- pression, two (2) per cent in ten- sion or diagonal tension, and four and one-halt (4x/z) per cent 1n Punching shear. Section 9.438. THICKNhSS Oh` CONCRE'PE WALLS. The mini mum thickness of plain concrete bearing walls shall be ten (10) inches Yor the uppermost thirty-five (35) feet of their height and srlll be increased Ponr (4) inches for each successive thirty-five (35) feet or Craotion thereof, measured downward frmn the top to the wall; except tint the trp story wall of a building not exceeding three (3) stories or terry (40) feeC in height, or the wall of a mie-story building may be eight (8) inches thick, provided that such 8-inch wall does not exceed Yonrteen (141 Ceet mtsupported height and that the roof beatna are hm•izoural, end except that exterior bearing walln of mte and two-family dwellings may be six (6) inches thick when noC more Lhan thirty (30) teat in height. When gable constnictimi is used Tm• such dwellings an addi- tional five (5) Peet is permitted to Lhe peak of the gable- When plain emlorete bearing walls of buildings more than three (3) stories high are stiffened at points not more than twelve (121 feet apart by cross walla, or by internal or external offsets or returns at least two (2) feat deep, they may he ten (10) inches thick Yor the uppermost seventy (70) feet of their height and shall be increased Ponr (4) inches in thickness for each Sueaesaive seventy (701 feet or fraction thereof. The minimum thichness of plain concrete exterior ncn fearing walls shall be ten (10) inches for the uppermost seventy (70) feet of (.heir height. and shall be increased four (41 inches for each successive thirty-flue (35) Peet or fraction thereof, measured downward from the top of the wall; except that the top story wall of a building not exceeding three stories or forty (40) feet in height, or rho wall oP a one-story commercial or indus- trial building tray be eight (8l inches thick, provided that such 8~inch wall does not exceed four- teen p41 feet unsupported height, and that the roof beam, are hori- zontal; and except that exterior non-Dearing walls of ono and two- family dwellings may be six (6) inches thick when of more than thirty (30) feet in height. When gable construction is used for such dwellings an additional five ;6) teat ie permitted to the Peale of the gable. FIOllow monolithic walls of Plain 14 veneered with brick, terra cotta, concrete shau nave the same net cross sectional area of material, irrespective of iris space wit]tin Lhe wall, as requtred for solid walls. The inner ant outer parts of such walls shall be securely braced and tied together with non-corrodible ties or other means to bring them into common action. Where (loot and roof systems are carried by such walls, provisimx shall he made for the distrLbutimx of these !oasis to the Pull cross section of the wall. l FOr interior wall requirements, see Sections 9.470 to 9.413, also 9.475 and 9.476 of this Chapter). Sectimx 9.434. REINFORCII- MENT. CONCRETF. WALLS. Re- inYm•coment, not lase than two- tenthe (2/10) of one (1) per cent computed on a vertioal height of twelve (12) inches, shall be placed over all wall openings and at corn- ers oY the strreture to prevent cracks. Flour and roof connectimt details shall he designed to trans- mit Safely the vertical and hori- zontal loads imposed. Section 9.436. PIERS. CON- CRE1'F. WALLS. The unsupported height oY isolated piers oY plain concrete shall not exceed ten (10) times (heir least dimension. (See definitimx, "Piers." Chapter 2 of this Code.) Section 2436. CHASES AND RECESSES, CONCRETE \YALT,S. Chases and recesses in plain con- crete walls shall not exceed in ex- tent those premitted for solid brink walla ender the same conditions. (See Section 9.416 of this Chapter) Section 9.440. W O R K I N G STRESSES. 9'PONE WALLS. The maximum allowable compressive stresses in rubble stmtework of sound and dense lava rock due to combined live and dead loads sImIL not exceed 140 Pounds per square inch when ]aid in Portland cement mortar, 100 pounds par square inch in natamal cement or cemm~t-limo mortar, and seventy (70) Pounds per square inch in lime mortar. The maximum allowable com- pressive stress in ashlar masonry due to combined live and dead loads shall not exceed the Yellow- ing limits: Maximum unit working stresses (Pounds per square Kroh) load in e~ ~ ~ ~ V [. V {, M `~ m o I::Iit C 7 L ~ LC ~ q ooS G.q .] Granite .__...__.__. 800 fi40 400 Limestone .-.._- ._- 500 400 260 Marble ______... _.. 500 400 250 Sandstone -__...__. 400 320 1G0 Blue Lava Rock._. 500 400 350 Section 9.441. LA'pERAL SCY- 1'ORT. STONE \\"AILS. Rabble stone walla shall bo four (4) inches thicker [ha~n is required for solid brick walls of the same respective heights, but in no Dart less than fourteen (14) inches. The minimum thickness fm' walls or piers oC ashlar masonry properly bonded shall be the same as re- mtired for solid brick walls and piers ender similar conditions. The lateral support for stone walls shall emtform to the same re- quirements specified for solid brick walls, Section 9.411 of this Chap- ter. Section 9.442. BOND F O R STONE WALLS. Bond stones ex- Lendiug through the wall and unl- i'ormly distributed shall be pro- vided to the extent. of not less than ten (10) per cent of the area, a.nd there shall bo at least one fll bond stone for every eight f8) stretchers. Section 9.443. CHASES AND RECESSES. STONE WALLS. Chases and recesses in stone walls shall not exceed in extent those permitted for solid brick walls un- der the same conditions. (See Section 9.416 of this Chapter.) Section 9.460. QUALITY OF MA- '1'ERIAI.S. VENL:E1tED WALLS. Materials used is the backing and veneering oY veneered walls shall conform in all respects to the re- quirements prescribed tar such materials in Sections 9.410, 9.420 and 9.430 of this Chapter. Stone or archlteetural terra-cotta, ashlar, m' other approved masonry ma- terial used for veneering, shall bo not less than three (3) inches nni- tiorm thickness- but all stones need not necessarily be the same thick- ness. Section 9.451. \\' O R K I N U STRESSES. VENEERED WALLS. The maximum allowable compres- sive stresses on the backing of veneered walls, due to combined live and dead loads, shall riot ex- ceed those elsewhere prescribed Tor masmxry of the type which fm~ms such backing. In no case shall 11te vmneering be considered a part oY the wall ir. computing the streng,h of bearing wells, nor shall it be cons-ldered a part of the re- quired thickness of the wall. Section 9.462. ATTACHMENT Oh' i'ENEERING. When walls are veneered with brick, terra cotta, stone or concrete trimstone the veneering shall be tied into the backinK either by a header for every 300 square Inches of wall sm•face or by substantial non- corrodible meta] wall LFes- spaced not. farther apart than one (1) Toot vertjeally and two (2) feet hori- zmxlally. Headers shall project at least three and three-YOnrths (8'Y,) iuehes into the backing cud anchm•s shall be of substan•ia.l pattern. 1Vhen veneering ie used special care shall be taken to fill all joints flush with mortar around wall openings. Section 2453. HEIGHT OF VE~ Nh;ERh:D WALLS. Veneer nn walls shall not exceed fi[tY (50) feet in height above foundations. Section 9.460. C?UALITY OF MATERIALS. FACED WALT.S. Materials need in the backing and Pacing of Laced walla shall conYm~m in all respects to the repuirements proscribed for such materials in 9ectious 9.410, 9.920 and 9.430 of this Chapter. Materials used for fixcinq shat] be not less Uxan three and three-YOUrths (3~+/~) inches Lhiek, and in no case less in thickness than one-eighth (''/H) flxe height of the unit, excepting that span- drel and other recessed panels, when approved, may be higher than eight ($) times their thicla rises, provided they are of the maximum thickness required; pro- vided, however, Lhat marble or Lerra cotta oC any thickness may be used for the first story walls only when such ie well secured by non-corroding ties to the walls. Section 9.461. WORK 1 N G STRESSES. FACED WALLS. The maximum allowable compressive stresses on faced walls due to com- bined live and dead loads shall not exceed those elsewhere prescribed for masonry of the type whioh Corms the backinK. Where bonded to the backing as provided in Sec- [imx 9.463 of this Chapter, the full cross section of the facing may be considered in comparing bear- ing strength. Section 9.462. THICKNESS. FACED WALLS. Faced walls shall be not less in thickness than Is re- quired for masonry walls of the type which forms the backing. \Vhere bonded to the backing as provided in Section 9.463 of this Chapter, the facing may be con- sid;.red a part of the wall thick- ]lee9. Section 9.463. BOND F O R FACED \VALLS~ Brick facing shall he bmded to walls rf brick or of hollow tits, or of concrete block or the with at least one fll header course in every cis (6) 15 courses, or there shag he at ]east one (1) full length header in every seventy-two (721 square inches oY wall surYaee. Stone ashlar facing sha^ have at least twenty (2U) per cent of the superficial area no[ lees than three and three fourths (33k) inches Uti eker ^xan the remainder of the Lacing to Porm bond stmtes, which shall be uniformly distributed throng9tout the wall. When some stones in every al- ternate course are at least seven and one-half (T4) inches thick, bonded into the backing at least three and threrfourihs (3'%) inch- es, and at ]east Twenty (30) pm' cent of the superficial area of the wall is constituted of such bond stone uniformly distributed, the ash tar facinK mxy be comnted as part oY the wall thickness. Every atone not a bond stone and every project- ing stone shall be secm•ely an- chored to the backing with sub- stantial non-corrodible metal an- chors. Section 9.470. BRICK A N D FLAIN CONCRETE FIRE WALLS. Solid brie.k or plain concrete fire walls shall not be less in thiclaxess than required for exterior bearing walls of corresponding height, brit not loss thou twelve (121 inches, except ]hat solid brick- fire walls Yor bni]dinKS of residential occup- ancy shall be not less than eight (8) inches thick Cor the nPpm~m oat riventY (201 feet of height and shall be at least twelve (1'2) inches thick for the remaining lower por- tion; and except that plain cou- rrete fire walls for such structures may be eight (8) inches through- out No 8 inch fire wall shall be broken into, anbsegnent to building, for the insertion of etruchtral mem- bers. (F'm• definitions of I9re Wills, see Chapter 5 oC this Code) ]'arty walls which ftmction also as fire walls shall conform to re- quiremmxts for fire walls. A separation of at ]east six (G) inches of solid masonry shall br provided in al] fire and party walls between combustible members which may enter such walls from opposite Sides. SecSOn 2471. FIRE WAT.hS OF HOLLOW TILE, C O N C R E 1' E 13LOCE OR CONCRETE TU,E, Olt OF HOLLOW WALL CONSTRUC TION. Fire walls oY hollow the or concrete block nr concrete tiler shall be not less than sixteen (1G) inches thick in anv part, excep7 that for rosidontfal buildings thc7 may be not less than twelve (12) inches thick throughout. Hollow walls of brick used as fire wa14. shall be not less titan twelve p21 inches thick throughout. Nn th'e walls oP the above type shall he broken into, snbseq}tent to arse Lion Cor the insertion of atructtn~a] members. Where combustible or unpro- tected steel building members frame into hollow party or fire walls oP thickness not greater than twelve (12) inches, they shall not prujert more than four (4) inches into the wall and shall be so spaced that the distance between enn- bedded ends is not less than Your f4) inches. The apace above. be- low and between lltem sha71 be filled solidly with burntrclay ma- teria,ls, mortar, concrete or equiv- alent fire-resistive material, to a depth of not less than four (4) inches on all sides of the members. All open cells i^ the or blocks occnring at wall ends shall be filled solidly with concrete for at ]east a depth of six (6) inches, or clns- nre the set in the opposite direc- tion shall be used. Party walls which ftmction also as fire walls shall conform to re- quirements for fire walls. Section 2472. FIRE DIVISION WALLS. Fire division walls of solid brick or plain concrete shall he not less than eight (8) inches thick. Fire division walls of hollow tile, or oT concrete block m' tile, shall be not less than twelve (12) inches thick in any part, and for buildings oY storage and heavy manufaclltring occupancy Lhey shall he not less than sixteen (lti) inches l.hick throughout. Hollow walls of brink used as faro division walls shall be not. loss Utan twelve (12) huhes thick throughout. Section 9.473. ALTERNATE R'U' (~UIREMENTS FOR FIRE ANll FIRE llLV1SlON WALLS. Wall oonstructioh that in fire tests con- ducted according to accepted stand- ards develop safe fire-resistau cc perloda of one and one-half (1',a) hours may be permitted Yor fire walls, and hie division walls be~ tw Bea residence occupancies, if otherwise adequate in point of strength and stability. for gon- ecal mercantile and mannl'actnring occupancies, exeludin6 buildings or portions of buildings' used for stm•- a6'e, wall construction developing. o^ the same basis, a safe fire-re- sistance pefiod of Wree (8) hours shalt bo similarly permitted. Section 9.474. PA RAYET Z~tALLS. lu al] first, semi-first, and second class buildings and "slow burning Ileavy timber conetrucfion" buildings, except as hereafter Pro- vided, all exterior walls mt all mercantile and coxnmercial build- ings shall continuo not less than three O feet above the roof and for other buildings two (2) feet above the roof, forming a parapet wall which shall be coped, which shall he of the same thickness as Lhe top story thickness, or eight tSl inches of masonry or six (d) inches of reinforced con- urete iY the Darapet is three (8) feet or under in height, and in the case of masonry shall he laid in cement nr cetncut-lime mor- tar Provided, however, that first lass buildings may have naves of reinforced concrete in lieu or Purape. s. All oponiugs In such eaves shall be cut off from the in- terior roof spate by suitable cut- off walls at least eight (3) inches in thickness. 1'rotided, Curtner, that second class buildings ntay have ouvee hr stead of parapets if such are e~~t- slructed as follows: 1. The rave or coping to have its cantor of gravity fn the tauter of the wall. 2. An effectual fire stop shall be mule at the ]unction with Lho $'ante roof dttpports. 3. Tice roof covering shall be rigid aebc;tos shingles, slate, clay tile, or other similar Pireproo covering. 4. Tho roof supports to be car- ried so that the weight of Lhe roof shall net affect the location of the center of gravity provided in Parer tp~aph of Lhis Section. Section 9.476. BEARING PAP,- TlT10N9. All interior bearing walls, except fie walls, fire divi~ s;ou walls and parry walls are cmtsidered as bearing partitions. Ibr bearing partitions, materials meeting the ordhtary aocePted local standards for the purpose may be used. Where not utilized ae party, fire m• Gre division walls, slid brink bearing partitions shall be not less ^tau eight (8) inches thick, sent those of hollow i.ile, concrete mock or concrete tile, or hollow walla of brick shall ho tent less in thickness Ihan one-eighteenth (1/18) oY the height between floors or floor beams. (N`or conditimts governing e.oucentratimte see Section 9.412 ui' this Chapter,) Secucn 9.47f. NON-BEAR LNG L'd It'1'Iq'ION S. For non-bearing partitions, materials meeting the ordinary accepted local standards for the purpose may be aced. 33ricl: non-bearing partitions shall be not less than three and one-fourth (3'G) inches thick for a height not exceeding twelve (12) feet between Boors or floor beams and for a length not ex- ceeding twenty (20) feet between vertical supports. Non-bearing Dartitions of hollow t11e, concrete block or emtcrete tile, plastered metal studded and metal lathed partitions, hollow walla of brick or of gypsum block or other similar materials shall be built solidly against floor and telling eonstrut- timt below and above, and shall not exceed the Loilowing' unsupported heights: ro ~ ~ a _ m .~ o r: y, ~~ n dam x7 a ~am ci o a ~k A' m ,~, ~ cz k a ~at ... N "~' A s' '~ A [. d o ~ a F[ o ~ 2 inches 12 feet fi inches 2J feet 3 inches 14 feat 8 inches 25 Ceet 4 inches Y6 Peet Suction 9.477. FOIINDATLON WALLS. Foundation walls Yor solid-wall tonstructlmt shall be of stone, solid brick tmtcrete (plain, rubble or reinforced), or concrete block. Solid brick foundation wails and those of concrete block or coursed stone shall be not less in thiclutese than the watts innne- diateiy above them and in no case less than twelve (12) inches thick, except Lhat when the inclosure is not excavated, they nmy be eight (8) inchos think iY included within the allowable height of eight (8) iueh walla. When built of concrete cast in Plato foundation walls shall beat least us thick as the walla sup- ported, but iu ten case less than night (8) inches. When built of rubb'.e stone, Lhey shall be at least sixteen (1G) inches thick. Rough or random rubble without bonding or level beds shall not be used as foundations for walls exceeding Lll ir~y-Gve (85) feet in height, nm• shalt coursed bonded rubble walls be used as fmmdationa Yor walls exceeding seventy-five (75) Peet in height. Foundation walls for hollow tile, ooncrete block or tile, hollow walls of brick, or frame construction, shall he oY the same thickness, reepett.vely, as required in the pares,,°raph above, and shall be built oi' brick, stone, conm•eto, (Dlain, cobble or reinforced). hollow tile. c xicre'e block or tire. or hollow walls of brick. Tile foundation walls shall bE 11 Ot le9S t}fall tW BiV f' (121 inches thick. VJhon the stresses doe to earth pre6snre and superimposed build- ing load exceed the maximum workinK stress elsewhere specified i'or brlek masonry, and the addi- tional stresses are not otherwise provided 1'or, the wall thickness shall be increased to bring thorn within these litni LS. Foundation walls for frame corv struction shall extend at least eight tS) inches above the adjoining ground surface. Yiaterials far Foundation walls shall be equal in quality in all respects to those required for ex- terior bearing walls, except that mortar containing lime in greater proportions by volume than one (1) part to one (1) part oT cement and six (6) parts of Saud shall not be used for exterior foundation wal!s- below grade. Soctian 9.478. PANN L AND F:N- OLOSTNG WALLS. Panel walls iu buildings of skeleton construction shall he not less than night (8) inches Gtick if of soled bri clr, hollow Gle, concrete block or tile, plain utncrote m~ hollow walls of brick. Inclosure walls shall be not lass than eight (3) inches thick nor less ht thickness than one-twentieth (1/20) the horizontal distance be- twoen anchors. Sectimt 9.488. NEW TYPN:S OF 1A4ASONRY CONSTRUCTION. Tho use of new or improved masonry materials or methods not covered by this Code may be permitted, providing that they conform to spa Cifi C&LIOn9 111511r1ng reasmlahle uniformity of the product; and t1mL Lhe stability and durability of such construction, and its resist- ance under fire expesnre, shalt have bent satisfactorily demou- etrated. Worklug stresses shall be fixed at not more Ihan twenty (20) per cent of Uto average ulti- mate strength oY masonry walls constricted of such materials, us deennined by res'p ~nsible authori- ties. Section 3.481. A N O II O R L N G WALLS- All waPs shall be se enrely anchored and bonded at points where they intersect. SOttIOCl 9482. l.SE Gig EA16T- 1NG WAT.LS. An existing brick wall may be used in the ran oval or extension of a building; or map he increased in height beyond that allowed 1'or constricoon, provided that such wall is atr'nc'.urally sound or can be made so by rcasmmble repairs. Walls increased in height shall be at least four (9) inches ihiclrer them is required by this Code for newly cents VUCted wul!s of such iam-eased height, and in uo case shall linings be less than eight (8) inches thick and ]aid in Portland cement mortar. The foun- dations and lateral supporC shall be equivalent Lo those elscwhcro required b}' this Code for newly coustructul walls under similar conditions. AL] linings shall be thoroughly bonded into existing masonry by toothings of brick m• stone to assure combined action of wall and lining. Such trtothinga shall be distributed fairly uniformly throughout the ty-all and shall ag~greg~ate in ver- tical cross soeLouaL area not less then Hfteen (16) per cent oP the total vertical area of the lining. No axis Cog wall shall he used for renewal or extension of a huilrl- iug, or increased in height wfWont special written permissimt from Lhe Building Inspector. Section 9.483. CORBELING OF CHIMNEYS. No brick wall less than twelve (L") in rh es thick sha^ bo used to support a corbeled chimney. Such corbeling shall not project more than xis (6) inches from the fare of the wall, and in all each cases the corbeling shall consist of at least five (5) ccurso-a of brick. No chimney shall bo corbeled from a wall built of hol- low tile, hollow concrete block, ton CLOLe tile, Or hollow waQ6 OY brick Section 9.484. CORNTCES. The centers of gravity of stone cornices shall he inside of the outer wall face. Terra cotta or metal car- nices shall be elnte[urally sup- ported from the roof oC the bnihl- ing, or as provided in Section 9.474. oP this Chapter. Suction 9.5011. REINFORCED CONCRETE. Roinforted concrete will he approved for al] types oY buildings, when such design con- forms to good r:nginem•iug prac- tice and Lhe stresses therein coxr form to the units provided by this Code. (Note: For quality and working stress, see Section 8.302 of this Code.) Section 9.602. TIIE CEMENT used in reinforced concrete shall pass the test specifications oP the American Society for Testing Mu- terlals for Pm•tland Cement. Section 9.603. INCREMENTS OF REINFORCFID CONCRETF, shall be such, and eo mixed and placed, Utat the designed strength shat] be met a~s stipula.ted in Sre- tione 8.801 to 8.303 of this Code. Suction 9.504. DESlU N. Rein- forced concrete computations shall be based upon the following as- sumption: 1. A plane seotion before bond- ing remains a plane seotion after bending. 2. Tho modulus of elasticity of concrete iu compression remains wustant witfiin flee working limits fixed by this Code 1d 3. The adhesion between con Crete and reinfm~cement is perfect. 4. Concrete has no resistance to tension. 5. Initial stress in the reinforce- ment duo to contraction or ex- pansion of the concrete is ^egli- gible. 6. "n" or the ratio of the moduli of elasticity of areal and concrete with ttn ultlmate crushing strength of 2,000 pounds shall be taken as fifteen (16), and "n" for 3,000 pounds concrete shall be taken as twelve (12). Section 9.506. THE SPA N LENGTH oY beams shall be taken center to center of supports, but need not be taken to exceed the clear span plus the over-all depth of beam or slab. Brackets shall sot be cmrsidored as reducing llxe clear span in the sense here in- tended. Section 9.506. BENDING MO- MENTS. The bending moments of slabs due to uniformly distributed loads shall be taken as not less than: 1/3 WL at canter when simply suPl~orted; 1/10 WL at center and continu- ous sapport when supported at one end and continmous at the other; 1/12 WL at center and interme- diate supports when contimtons over more than two (L) supports; W is the total distributed dead and live loads; h is the length o[ span. Section 9.607. RENDING MO- MENTS ON` SLABS SUPPORT7~ID ON FOUR SIDES. When slabs are reinforced in both directions, and supported on tour (4) sides, the same coe}iicients as prescribed in the preceding section Yor slabs may be used in each direction. Tho loading, however, shall be desiKn ed in accordance with the formula 1° r in which 1=the length 1'}h' and b the breadth of the slab, and r-the proportion o[ the load car- ried by the transverse reinforce- ment If 1 exceeds 1. 6 b, the trans-vers-e reinforcement shall be considered to carry the entire load. Section 9508. CONT1N UOl~S REAMS. In coulimxons beams, Lhe extreme fiber stress in concrete in compression may be increased fif- teen (16) per cent adjacent to Lhe supports. Section 9.509. SHEARING STRESSES. hx computing the section of concrete for shear, tLe depth below the center of com- pression and the center of tension shall be need. Section 9.510. BEiVDING MO- MENTS FOR REAMS AND GIRD- ERS. Beading moment coefficients for beams anfl girders shall be the same na Ynr slabs (see Section 9.606 of this Chapter) mxl~ss of unusual length, in which case ac- cepted theory of design shall be used. Sectimi 3.511. RENDING b10- MENTS oY slabs, beams or girders, which are conlinnons over two {`L) spans only, shall be taken as 'ls WL over the central sapport, and ]/10 WI, near the middle of the span. Section 9.612. NEGATIVE MO- MENTS AT SUPPORTS. Provi- simxfar bending of cmrtinuous slabs, beams and girders at supports shall be made with sufficient bend of steel therefor to insure proper de- velopment of tensile strength. Section 9.513. WEB R F 1 N- PORCh;ME1VT IN REAMS. Beams and girders shall be provided with stirrups or bent-up bare or both to resist the shearing stresses when such exceed the diagm~al shearing strength of the coum~eto. Stir- rups, iP necessary, shall not be spaced greater than three-Conrths ('$i) the depth of the beam or girder. Stirrups and bent bars shall be 9o fixed as [o dnvelop the necessary tensile strength of the reinfm•coment. Section 9.614. T BEAMS. With monolithic casting of slabs and beams the slab xnay be deemed a portion of the beam and so com- puted. The overhanKing slab on each side so considered shall be not more than one-sixth (1/6) the span or four (4) Limes the thickness of the slab. For the calculation of longitudinal shear and diagonal tension, the stem of the 'P only shall be considered. At supports, continuous T booms shall he reinforced for the nega- tive moment, if necessary, with reinforcement of sufficient length to insure proper bond. Section 9.517. BENDING AND DIRECT STRESS IN COLUMNS. BendinK and direct stress in col- umns shall be so computed that file safe working stress in the ex- treme fiber shall be not exceeded. The following formula may be used for this computatimx: My P Pl' A 1- -- lOF. in which Y,-:fiber stress due to bending; f,=fiber stress due to direct load- ing; y=distanre from neutral axis to the extreme fiber on the side of masimnm compression; M-=bending moment due to the eccentric load; P-the direct compressive load; 1=the length of the member i^ inches; -.-the unit compressive stress A in pounds per square inch. E=the modulus of elaetcity of material. Section 9.518. FLAT SLAB CON- STRUCTION. (a) Limitations. Flat-slab con- struction shall refer to concrete ;labs having reinforcement bars extending in two or four directions, without beams or girders to carry the load to supporting members and with a ratio of length to width of panel not greater than 1.33. The moment coefficients, mmnent distri- bution and slab thicknesses speci• fled herein are for slabs which have three or more rows of panels, in each direction, and in which tine panels are approximately uni- form in size. Slabs with paneled ceiling or with depressed paneling in the floor shall be considered as coming under the requirements herein given, provided the depth of the thicker portion of the slab does not exceed 1.5 times the depth of the remainder of the slab. (bl Panel Strips and Principal Design Section. A flat-slab panel shall be considered as consisting of strfns as follows: A middle strap one-half panel in width, symmetrical with res- pect to the pane] center line and extending through the panel in the direction in which moments are being considered; Two Oolumn strips, eaokx one- quarter panel in width, occupying the two 121 quarter-panel areas outside of the middle strip. Wl:mr considering moments in the direction of the width of the panel, the panel is similarly di- vided by strips, the v/idth of which are respectively one-half and one-fourth of the length of the panel. The principal design sections are located as follows: Sections for Negative Moment shall be taken along the edges of the panel; that is, along the lines joining the column centers. For the column strips, the section shall follow the center line be- tween the columns to the edge of the column capital and then around the circumference of the column capital for one-quarter ('/n) circumference. Sections for Positive Moment shall be taken on the center line of the panel, crossing the strips for which moments are being considered. (c) Moments in Interior Panels. Flat-slabs in which -the ratio of reinforcement, p, for negative mo- ment in the column strip is not greater than 0.01, the numerical sum of the positive and negative moments in the direction of either side oP a rectangular panel shall be not less than that given by Formula 19. M0.09w1 (12e/3D". _.....__(19) ld) Moments in Principal Design Sections. The moments in the prin- cipal design sections shall be those given in the accompanying table oY moments, except as follows: tD The sum oP maximum ne- gative moments in the two column strips maY be greater or less than the values given in the table of moments by not more than 0.03 Mo. (2) The maximum negative and the maximum positive moments in the middle strip and the sum of the maximum positive momenta in the two column strips may be greater or less than the values giv- en in the table of moments by not more than 0.01 Mo. BENDING MOMENTS TO BE USED IN DESIGN OF FLAT SLABS For Interior Panels Fully Continuous Flat-Slabs without Flnt-Slabs with Strip ~ Dropped Panels Dropped Panels Negative I Positive I Negative Positive Slabs with 2-way Reinforcement Column strip ..___ ~ U.23 Mo 0.11 Mo 0.25 Mo 0.10 Mo 2-Columnstrips._. 0.46 Mo 0.22 Mo I 0.50 Mo 0.20 Mo Middle strip -___. i 0.16 Mo 0.16 Mo 0.15 Mo 0.15 Mo Slabs with 4-way Reinforcement Column strip _._._ ~ 0.25 Mo 0.10 Mo 0.27 Mo 0.095 Mo 2-Columnstrips.._ I 0.50 Mo I 0.20 Mo 0.54 Mo 0.190 Mo Middle strip .___. I 0.10 Mo I'., 0.20 Mo 0.08 Mo 0.190 Mo (e) Lateral Dimensions of dropped panel. The dropped pan- nel shall have a length or diameter in each direction paralled to a side of the panel of not less than one-third the panel length in that direction. (f) Thickness of Slabs and dropped Panels. The total thickness of the slab through the dropped panel, t, in inches, or oY the slab if a dropped panel is not used, shall be not less than the value given by Formula 20. t, 0.038 (1-1.44 c/ll 1 Note. The values of R in the above formula are the co-efficients of Mu in the preceding table in this Section. For slabs with dropped panels the total thickness in inches at points beyond the dropped panel shall be not less than 17 The dropped panel shall have a thickness of t, not greater than 1.5t_. In determining minimum thick- ness by Formulas 20 and 21, the value of 1 shall be the panel length center to center of the columns, on the long side of panel and the value of 1. shall be the pane] width, center to center oY Lhe columns. The slab thickness t, or t: shall in no case be less than 1/32 for floor slabs, and not less than 1/40 for roof slabs. (g) Wall and Other Irregular Panels. In wall panels and other panels in which the slab is not continuous with an adjacent panel, the maximum negative moment at the edge of the panel opposite to the discontinuous edge and the maximum positive moment at the center of this panel shall be increased fifteen (15) per cent in the column strip perpendicular to the wall or discontinuous edge and thirty (30) per cent in the middle strip perpendicular to the wall or discontinuous edge. Such in- crease refers to the moments for interior panels as specified in pa- ragraph (d) of this Section. In these strips the bars used for positive moments perpendicu- lar to the discontinuous edge shall extend to the edge of the panel at which the slab is discontinuous. At the wall or discontinuous edge the negative moment in Lhe column strip shall be taken as not lees than ninety (90) per cent and in the middle strip as not less than sixty-five (65) per cent of the cor- respontling moments for a normal interior panel as given in the table in paragraph (d) of this Section. (h) Panels with Marginal Beams. A marginal beam which has a depth greater than the thickness of the dropped panel into which it frames, shall be designed to car- ry. in addition to the load super- imposed directly upon it, a uni- formly distributed load equal to at least one-fourth of the total live and dead load for which the adjacent panel or panels are de- signed. Slabs supported by mar- ginal beams on opposite edges shall be designed as freely supported slabs for the entire load. Colrunn strips adjacent to and parallel with marginal beams hav- ing adepth less than the thickness cf the dropped pane], shall be de- signed to resist the moment speci- fied for a column strip in the table of moments. Column strips adjacent to and parallel with mar- ginal beams having a depth less than the thickness of the dropped panel, shall be designed to resist a m^ment at least one-half as great as that specified for a column strip in the table of moments. In wall columns where brackets are used in place of capitals, the value of c in the direction in which the bracket extends shall be taken as twice the distance from the center oP the column to a point one and one-half (1'F~) inches back from the edge of the bracket and averaged with the value of c for an interior column capital in the computation for moments in Form- ula 19. The value of c for column strips parallel and adjacent to marginal beams shall be taken as equal to the width of the wall column if no bracket is used in this direction. (i) Flat-slabs on Bearing Walls. Whero there is a beam or a bearing wall at the center line of columns in the interior portion of a con- tinuous flat slab, the negative mo- ment at the beam or wall line in the middle strip perpendicular to the beam or wall shall be taken as thirty BO) pee cent greater than the negative moment specified in the table of moments in para- graph (d) of this 6ection for a middle strip. The column strip adjaent to and lying on either side of the beam or wall shall be designed to resist moments at least one-half of those specified in the table of moments for a column strip. (j) Points of Inflection. In the middle strip the point of inflec- tion for the slabs without dropped panels shall be assumed at a line 0.30 1 distant from the center of the span, and for slabs with dropped Fanels 0.25 1 distant from the center of the span. In the column strip the point of inflection for slabs without dropped panels shall be at a line 0.30 (1-c) distant from the center of the panel and 0.25 (1-c) Por slabs with dropped panels. (k) Effective Reinforcement. The reinforcement which crosses nny section and which fulfills the re- quirements given in paragraph (ll of this Section may be considered as effeotive in resisting the moment at the section. The sectional area of a bar multiplied by the cosine of the angle between the direotion of the axis of the bar and any other direction may be considered effective as reinforcement in that direction. (ll Arrangement of Reinforce- ment. The reinforcement shall be securely fastened in place. A]1 bars in rectangular or diagonal di- rections r:hall be carried to points at least twenty (20) diameters be- yond the point of inflection an each side of a section of oritical, 1: ositive, or negative moment. Lapped splices shall not be per- mdtted at or near regions of maxi- mum stress except as follows: In slabs, beams and girders, spiices of reinforcement s h a 11 not be made at points of maxi- mum stress without the approval of the Building Inspector. Splices, where permitted, shall provide sufficient lap to transfer the sCress between bars by bond and shear. Where changes in the cross- section of a compressior. member occur, the longitudinal bars shall be sloped for the full length of the member or offset in a region where lateral support is afford- ed. Where offset, the elope oP the inclined portion from the axis of the member shall not be more than 1 in 6. At least four-tenths (0.4) of all bars in each direction shall be of such length and shall be so placed as to provide reinforcement at two sections of critical negative mo- ment and at the intermediate sec- tion of critical positive moment. Not less than one-third of the bars used for positive reinforce- ment in the column strip shall ex- tend into the dropped panel at least twenty (20) diamaters of the bar, or in case no dropped panel is used, shall extend to within one- eighth P/a) of the span length from the center line of the column or the support. (m) Special Panel Arrangement. For structures having a width of less than three rows of panels, or in which irregular or special panels are usen, an analysis shall be made oT the moments developed in both slabs and columns. Sectio¢ 9.519. REINFORCED CONCRETE COLUMNS. (a? Limiting Dimensions. Re~n- forced concrete coiumns shall be not longer than forty (40) times the least radius of gyration, unless designed as long columns as speci- fied in paragraph (h) of this Sec- tion. Principal columns shall have a minimum gross diameter of not less than twelve (12) inches. (b) Unsupported Length and Ra- dius of Gyration of Columns. The unsupported length of reinforced concrete columns shall be: (ll In flat-slab co¢struction the clear distanoe between the floor and under side of the capi- tal or dropped panel above; (2) In beam-and-slab con- struction, the clear distance be- tween the floor and the under side of the shallowest beam fram- ing into the column at the next higher floor level; (3) In floor oonstruotion with beams in one direction only, the clear distance between floor slabs; l4) In columns supported lat- erally by struts or beams only, the clear distance between con- aeoubive pairs (or groups) of struts or beams, provided that to be considered an adequate sup- port, two such struts or beams shall meet the column at ap- proximately the same level and the angle between the two planes formed by the axis of the column and the axis of eaoh strut res- pectively is not less than seven- ty-five (75) deg. nor more than one hundred five (105) deg. When haunches are used at the junction of beams or struts with columns, the clear distance between supports may be con- sidered as reduced by two-thirds of the depth of the haunch. The radius of gyration of a column shall be computed from the concrete area of the core and the transformed section of the longitudinat steel area. That is, the actual area of the steel multi- plied by n, this being assumed to be distributed uniformly around the periphery of the core. (c) Design of Spiral Columns. The safe axial load on columns re- inforced with longitudinal bars and closely spaced spirals enclos- ing a circular core, shall be not greater than that determined by Formula 22. PA [l+ (n-ll pi [300+ (0.10+4p) f'c .. (22) The longitudinal reinforcement shall consist of at least six bars of minimum diameter of one-half (~Gz) inch, and the total effective cross- sectional area shall be not less than one (ll per cent nor more than six (6) per cent of that of the core. The spiral reinforcement shall be not less than one-fourth ('/,) the volume of the longitudinal rein- forcement. Ii shall consist of even- ly spaced continuous spirals held firmly in place and true to line by at least three vertical spacer bars. The spacing of the spirals shall be not greater than one- sixth (1/6) of the diameter of the Dore and in no ease more than three (3) inches. Reinforcement shall be protected by a covering of concrete, cast mo- nolithic with the core, of a thick- ness not less than that specified. (d) Design of Columns with Lateral Ties. The safe axial load on column; reinforced with longi- tudinal bars and separate lateral ties shall be not greater than that determined by Formula 23. P=(A'c+Asn) fc (23) fc shall not exceed 0.20 f'c. The amount of longitudinal rein- forcement shall be not less than five-tenths (0.5) per cent nor shall the amount considered in the cal- culations be more than two (2) per cent of the total area of the column. The longitudinal reinforce- ment shall consist of not less than four bars of minimum diameter of one-half ('Fz) inoh and shall be protected by a covering of con- crete, cast monolithic with the column. Lateral ties shall be at least one- quarter ('/) inch in diameter, spaced not more than eight B) inches apart and the points of successive ties shall be placed in rotation around the column. (e) Bending In Columns. The bending moments in interior and exterior columns shall be determ- ined on the basis of loading con- 1S ditions and end restraint and shall be provided for in the design. In flat-slab construction, a bend- ing moment at all interior columns equal to W.1/40 shall be assumed to cover all ordinary cases of un- equal loading in floors and roofs. In this formula W,= the total live load on one panel and 1= the span, center to center of columns, lengthwise to the panels. Known eccentric loads and uneven spac- ing of columns shall be provided for in the design. Resistance to these bending moments shall be provided in the columns immedi- ately above and below in dfrect proportion to the values of their radios of 1/h (See paragraph (b) of this Section). In columns sup- porting roofs the moment shall be resisted by the column below. Wall columns in flat-slab con- struction shall be designed to re- sist bending in the same manner as interior columns except that the total live and dead load in the panel shall be used instead oY the live load only when comput- ing the moment. Any counter mo- ment due to the weight of the structure that projects beyond the column center line may be deducted from the moment computed as just described. The limiting unit stresses due to the combined axial load and bend- ing shall be determined as follows: (ll Wlth Spiral Reinforcement -The compressive unit stress at (Continued from Page 11) the extreme f1Ure on the con- crete within the core area undel combined axial load and bend- ing shall not exceed the value given by the expression 3001 (0.10}4P> f'p. (2) With Lateral Ties-Ad- ditional longitudinal reinforce- ment may be used if required to provide for the bending stresses, and the compressive unit stress at the extreme fibre on the con- crete under combined axial load and bending may be increased to 0.30 f'c. The column section, however, shall be not less than that required by the provisions of paragraph (d) of this Sec- tion where axial load alone is considered. The total amount of reinforcement considered in the computations for combined stress shall be not more than four (4i per cent of the total area of the cohtmn. (f) Oomposite Columns. The safe load on composite columns in which a structural steel or cast- iron column is thoroughly encased in a circumferentially reinforced concrete core shall be based on a unit stress of 0.25 f'c on the area within the spiral core plus the unit compressive stress on the steel or cast-iron core as determined by Formulae 24 and 25 respectively. 18,000 fr h' .___..._.....(241 1} 18,000 R° but shall not exceed 16,000 lbs. per sq. in. fr=12,000-60 h/R........__._.(25) but shall net exceed 10,000 lbs. per sq. in. The diameter of tl.e cast-iron section shall not exceed one-half of the diameter of the core within the spiral. The spiral reinforcement shall be not less than flue-tenths (0.5) per cent of the volume of the core within the spiral and sYtall conform in quality, spacing and other requirements to the pro- visions for spirals in paragraph (c) of this Section. Ample section of concrete and continuity of reinforcement shall be provided at the junction with Ueams or girders. The area oY the concrete between the spiral and the metal core shall be not less than that required to carry the to- tai floor load of the story shove on the basis of a stress in the con- crete of 0.35 f'c unless special brackets are arranged on the metal core to receive directly the beam or slab load. (g) Structural 6teel Columns. The safe load on a structural steel column of a section which fully en- cases an area of concrete and which is protected by an outside shell of conorete at least three (3) inches thick, shall be computed in the same manner as for composite columns in paragraph (f) of Sec- tion 9.519, allowing 0.25 f'c on the area of the concrete enclosed by the steel section. The outside shell shall be reinforced by wire mesh weighing not less than two-tenths (0.2) lbs. per sq. ft. or by ties or spirals of equal weight, and with a spacing of not more than six (6) inches between strands or hoops. Special brackets shall be used to receive the entire floor load at each story. The safe load in steel columns calculated by Formula 24 shall not exceed 16,000 lbs. per sq. ln. (h) Long Columns. The permis- sible working load on the core in axially loaded columns which have a length greater than forty (40) times the least radius of gyration of the column core (40R) shall be not greater than that determined by Formula 26. P'=P (1.33-h/720 R)......_.._(20) Section 9.520. PLACING REIN- FORCEMENT. Metal reinforce- ment shall be accurately placed and secured and shall be supported by chairs, spacers, or hangers. The minimum clear distance between parallel bars shall be one and one- halP (h/s) times the diameter for round bars or one and one-half (ll/z) times the diagonal for square bars. The minimum clear distance between bars and forms shall be the diameter of round bars and the diagonal of square bars. If the ends of bars are anchored in an approved manner, the clear spacing may be made equal to the diameter of round bars or to the diagonal of square bars, but in no case shall the spacing between bars be less than one (ll inch, nor less than one and one-third (11/3) times the maximum size of the coarse aggregate. The main longi- tudinal slab steel shall be spaced not more than two and one-half (2'fa> times the slab thickness, and not less than one-tenth (1/10) of one (ll per cent of transverse steel shall be provided. Set ion 9.621. PROTECTION OF REINFORCEMENT. Steel re- inforcement shall have a mintmum protection of concrete on all sides as follows Columns, beams and girders _._..._______..._. 2inches Floor and roof slabs and 1Valls 1 inch Footings and foundations 2inches In all cases aufflcient bond shall be provided. Section 9 623. MIXING AND PLACING. Concrete shall be so mixed. transported and placed that the fall designed strength is as- sured consistently throughout the structure. Secton 9.624. FORMS. Form work shall be ao placed and se- cured that the designed shapes and concrete strength is assured con- sistenUy throughout the stnmture. Forms shall not be removed before sufficient strength of the concrete has been secured to insure its sta- bility, and except upon the aperial written permission of the Btalding Inspector. The following time al- lowable for stripping shall be not reduced: Walla and columna- eeven (7) days; Floor and ceiling slabs-ten (10) days; Beams and girders-twenty (20) days. Section 9.600. STEEL TRUS- SES. Steel trusses may be of tnh- ing or structural shapes, and may be welded, riveted, bolted or other- wise fastened, so that the stresses are carried in an adequate manner consistent with the permanency of the steel itaelY. Where gas or electric err, weld- ing is used, the spliced section shall be built up so that the metal at Gte splice is such that at least a consistent strength is provided for the whole. a safe vane ~s fifty (60) per rent greater se~~~iou spector may require the test of at the weld. 'Phe Bmlding In- specixnens and a demmxstra[ion of the competency of worktu en o^ this class of construction. Electric spot welding is permis- sible bat subject to test for design strength. 9uificient away and IateraL bracing shall be provided throughout. Section 0.601. llES1GN. Steel trusses s'.tall be so designed thai the whole is statioally determinate, disregarding rigidity of joints. Section 9.602. STEEL GIItllERS ANll BEAMS. The thickness of the web ht built-np girders shall be not leas than one-one hmtdredth and twentieth (1/120) oY the dis- tance between the flange angles or stifeners, nor less than one-fourth ('/,) inch. Witen the unsupported length (1) of the compression flange oY a girder exceeds ten (10) times its width (b) the unit etreas in aach flange shall not exceed 16,000-- 1 150-. The length and width t°e b in inches. The unsupported length of the compression flange shall not be greater than forty (40) times Ito width. S[i Renere shall be provided over supports, and under concentrated loads, and shall be sufficiently fast- ened or secured to tranamlC the stresses of the web. If the unsupported depth of web plate exceeds sixty (60) times its thleknesa, intermediate stiffeners shall be provided. All stiffeners shall be in Pairs with close bear- ing against the fiang~e angles. On masonry bearings, plates or cast seats shall be provided to dis- tribute the load wihin allowable limits. Section 9.603. RIVETING OF STEEL. The distance Yrom the edge of the hole to the edge of the piece shall not be less than one and one-half (1.5) d. where d is the diameter of the hole. Rivets shall be machine driven wherever possible. The pitch Of rivets shall not be lees than three (3) diameters of the rivet, nor more than eight (8) inches. Section 9.604. PROTECTION OF STEEL MF,MBF.RS. All structural metal work shall be cleaned of all scale, dirt and rust and except when embedded in cement or con- creie shall be thoroughly coated with at least one (1) coat oY nom corroding paint before leaving Lhe shop or before erection. After erection, all places left Yor ahoD marks, all abraaiona, and all rivet heads and bolts shall be painted, after which the entiro frame shall be painted with at least one (1) additional coat of tint diRerent from the first. All iron or steel used below the ground water level shall be in- closed by Portland cement con- crete. WOOD CONSTRUCTION Section 9.700. WOOD BEAMS AND JOISTS. Beams and joiata in fire or party walls shall be separated from any other beam on the opposite side of aach wall by at ]cask six (6) inches of tight masonry. All such beams or joists shall be self-releasing. Al] beams shall have adequate bearing areas. Section 9.701. THICKNESS OF WOOD BEAMS AND JOISTS. No wood beam or joist shall be less than two (2) Inches in [hlcknesa, commercial size. is Section 9.702. ANCHORS FOR BEAMS AND JOISTS. Beams and joists shall be anchored, when in masonry walls, at least every six (8) feet along the wall. When such beams or joists parallel the wall, anchor straps shall be an- chored in the wall and shall Bross and be flied to not leas than two (2) such beams, shall extend not less than three (3) feet out Crom the wall and shall be not more lhan six (6) feet on centers. (Sae Sec- timt 8.306 of this Code.) Section 9.703. TIMBER COL- UMNS. Timber columns which ex- ceed a ratio of length to diameter of twenty-flue (25) to thirty (30) and having pin end connections shall be designed according to the table in Section 8.305 or in accord- ance with the Euler Formula. P `L74 E A / L \' \ d / where - is the allowable unit col- A mm~ stress in pomtds per square inch, E is the modulus of elastic- ity; L is the unsupported length i^ inches; d is the ]east dimen- sion of column in inches. (For working strengths see Section 5.305 of this Code.) Section 9.704. CONSTRUC'pION DETAILS. WOOD COLUMNS. All columns shall be squared and so anchored as to insare an even and square seat at the bearing ends. Where columns continue through floors, girders or beams shall not separate the bearing ends of col- umns, but shall be connected by castings or plates or other approved connections. All bolts need shall have iron washers to diah•ibnte [he stress within the allowances of ma- terial strength stipulated in 6ec- tion R.305 oP this Code. Section 9.705. TERMITF, PRO- TECTION. Al] wood fopndation construction shall be given a Tho- rough and complete approved coat- ing of coal tar creosote or other approved deterrent. Foundation eonetrnctiou shall include :>Jl tim- ber below the Grst floor. as joists, braves, sills, posts and exterior trim. Exterior tom may be trea~ed with zinc chloride in lieu of the creosote above required. No wood aonstruotion shall be placed nearer than six f6) inches CO the gTOn1U1 6llrfaCB, lllllesa ap- proval therefor is obtained ill writ- ing from the Building inspector. All masonry foundation consll-nc- tion supporting Crams construction shall bo either Portland cement. con- crete or masonry laid np in Port- land cement mortar, or other ap- Droved equivalent termite resisting cmisunction All wood resting on ntaemtry which is within rivelve (12) inchex of the ground surface, whether above or below the first floor, sha71 be treated es hm•ein- bePOre provided for Poundatimt con- struction and shall bo capped with not lees than one (1) lush of Port- land cement mortar. On all posts and sills a termite shield shall be provided, cortin wing romplel ely around the foundation supports and including all supports and piping and so constructed that access to the supera'trpedlre by termites crawling from the grmmd is obstructed by such shield. Shields shall be of sheets of non- corrosive metal projecting at Least two (2) inches out from Ute sur- face. and bent doamward at an angle of forty-five (46°) degrees. and shall not exceed one sixteenth (1/16) inch in thickness. 911 openings into attics, roof spaces or other sf milar openings into unoccupied spaces except spaces below the first floor shall have non-corroding metal screen not larger than sixteen (16) mesh, and the wires of which are not smaller than No. 23 Browny sad Sharpe gauge. All wood forms ou concrete con- stnmtion shall be removed within forty-five (45) days from the pour- ing of the concrete. Section 9.706. FRAME BUILD- INGS. Frame third class buildings may be constructed of single one (1) inch nominal thickness board walls without studs for one (1) story in height where such hoe cross partitions at ]easC for every thirty (30) feeC of such wall 'pwo- etory third class buildings may be constructed oY single wall for the upper story, but shall he supported by studded walls below. Studding shall be not less than two by three (2x31 inches, and shall be so braced to amply carry the loads imposed. Section 9.707. BRACING FRAME BUiT.DINGS. When frame dweio- lugs are supported by posts, knee bracing shall be provided of suffi- cient strength tp stabilize the struc- ture against movement from wind pressure in any direction. Single wall construction shat] be braced with not less than two by six (2xf) belt course between the floor and the ceiling. CHAPTER 10 PRECAUTIONS DURING BUILD- ING OPERATIONS Section 10.100. STORAGE OF MATERIALS AND USE AND PRO- 'PF.CTION OF S1llEWALKS AND STREETS. Street and sidewalk areas may be used to facilitate building construction upon the foi- lowing conditions: 1. Sidewalks shall be protected witlr a substantial board fence at leasC eight (8) feet high con- structed along the center line of the sidewalk, and decked over to amply protect pedestrians passing below. 2. The street area shall not be used except under very special con- ditions, in which event application for street use shall be made in writing to the Building Inspector. A permit therefor may be approved by the Building Inspector in his smind discretion, and shall be for a period not to exceed twenty (20) days. Anew permit may be issued Yor Lur[her time if deemed advis- able. 3. Depositing of materials, ex- cavated earth, or debris on aide- wulk or street areas shall not ex- ceed twenty-four hours. This pro- vision shall not be defeated by re- placement oY ^ew material. Pro- vided, however, that a permit there- for may be issued as hereinbefore provided. 4. R'here sidewalk areas are excavated Yor basement areas or foundations, the street area be- yond the curb shall be supported and protected by anitabla retaining walls and the sidewalk area shall he maintained with suitable and sate temporary planking as pro- vided in Paragraph 1 of this Sec- tion. Section 10.200. PROTECTION OF PUBLIC. Wherever an ex- cavation is made Yor building, or material is stored, or blasting is being done, or the usual condition of the public ways diarilrbed in such manner as to produce a dan- gerous cond[tion, the person caoa- ing anv such condition shall main- tain proper safeguards either by proper Demons posted to warn the public, or by other approved means as railings, guards, signs or warn- ings, and at night by red warning lights conspicuously posted. Section 10.300. F'ROTECTfON OF WORKMEN. Temporary con- struction, scaffolding, ladders, stays, cables, hoists, temporary electrical lines. gangways, staging a.nd similar temporary devices used in construction shall be sub- stantially guarded, constructed and maintained to insure al] reasonable safety to the workmen employed on the premiaea, and it shall be the duty of the Building Inspectm~ to investigate and report upon the responsibility of all serious acci- dents on construction work to the Board of Supervisors as to the adequacy of precautions on xho work, apd in general to see that all reasonable precautions are Lak- en on all constnmtion work nndrr his snpotwieion. Section 10.900. PROTECTION OF ADJACEN'p PROl'ERTV. The depth 'oY ten (lU) feet below the adjacent curb eleva.linn is hereby fixed as the standard depth of Poundatlons. Any person excavat- ing to a greater depth Yhan the above standard shall protect the adjoining property from any dam- ages from such excavation. No per- son constructing foundations to the standard depth or less shall be liable Tor damages to adjoining property, provided, however, that the Superintendent of Buildings shall be given due notice of th^ possible damage or danger. It shall be the duty of the Buperintendent of Buildings, upon receipt of such notice, W examine the premises and notify the owner of the threatened building, his opinion of the work necessary to make his structure safe, and the owner of the threat- ened building shall have the right Lo enter upon the property of the adjoining owner in order to do the work necessary to make his building safe. Such work shall be promptly and expeditiously carried out so as to interfere as little as possible with the construction of the adjoining owner, and in the event of controversy the Super- intendent oP Buildings shall decide the questions at issue. Section 10.600. UTiLITV AND SANITATION REQUIREMENTS. All constrnetiou work shall provide sufficient toilets or portable ap- proved latrines for the accommo- datimt of the workmen, or arrange- ments made Yor the use of spch accommodations upon adjoining premises. CHAPTER 11 FIRE PROTECTION Sect ion 11.100. FIRE RESIS- TIVE MATERiAF.S. Whenever any new material is proposed not enumerated in Chapter 2 of this Code, ae "Fire-proof" or "Fire Re- sisting;' the National Board of Fire Underwriters' tests thereon shall be considered as a compara- tive guide for the determination oY its classificatioxl. Section 11.200. PROTECTION OF WALL COLIIMNS. All col- umns which support steel girders carrying exterior walls, and all columns which are built into walls and support floors only, shall he protected against corrosion by a coating of Portland cement mortar at least one-fourtlt (t/a) inch thick, and against moisture and fire by a casing of masmlry which shall be not less than four (4) inches of brick m• three (3) inches of eon- crete on all surfaces; all Lo be well bonded into the masonry of The enclosing walls. In the avant concrete is used the initial plaster coat may be omitted. Section 11.201. I'ROTF.CTION OF WALL GIRDERS. The wall girders shall have a casing of Port- land cement mortar and the same masonry protectimt as required Eor wall columns, all to be securely tied and bonded; but the extreme outer edge of the flanges of beams, or plates or angles connected to the beams may project within two (2) inches of the outside surface of such caein g. The inside surfaces of Lhe girders shall be similarly protected by masonry, or if pro- jecting inside the walls, they shall be protected by concrete, terra cotta, or other approved fireproof material not less than two t2) inches thick. Section 11.202. PROTECTION Ol` OTHER STRUCTURAL MEM- 20 BERS. All metal structural ment- bera which support loads or resist stresses other ^ian those provided for by the two (2) preceding pat•a- g=rapha shall have a protection of fireproofing as herein specified. The protection material shall be brick, concrete, rile or gypsum tllock, Concrete shall be not weaker than u 1:2:4 mixture. Tile may be solid or hollow, and shall be porous or 8eml-p OrmtB; Ilelther sheds nOr webs shall be less than five-eighths <"a) inoh think. Gypsum blocks shall be solid and of quality ap- proved by the Bnihling htspector. Plaster shall not be considered a part of any required fireproofing 1'or metal structural members ex- cept where specifically mentioned as such. Suction 1Y.203. MORTAR FOR MASONRY FIREPROOFING. All bricks or blocks used Por fireproof- ing shall be eet in Portland cement mortar, except that gypsum blocks may be set in gypsum mortar. Section 11-204. PROTECTION OF 1NT17RIOR COLUMNS. 1. The protection shall cover Lhe columns at all points to a thickness of not leas than three (3) lathes and be continuous from the base to the top of the column. The extreme outer edges of Lugs, brackets and similar supporting metal may project to within mte (1) inch of the outer surface oY the protection. 2. IC brick or blocks are used for fireproofing columns, they shall be accurately fitted, laid with brok- en jotrtts, and all spaces betwee^ trte outside layer and the metal solidly filled with masonry; or a oona'eto filling may be need. No voids between Lho metal and the protecting casing shall be permit- ted. S. Galvanized steel wire, not smaller than No. 12 gauge, shall be securely wrapped around block col- umn coverings so that every block is crossed at ]east once by a wire. The wire shall not be wmmd spiral- ly around the column, but each turn or band shall be a eeperate unit and shall be twisted tightly or otherwise securely bound. Other equivalent anchorage may be em- ployed if approved by the Building Inspector. No block used for this purpose shall exceed twelve (12) inches i^ vm•tica] dimension. Note: Any method which would securely lock the blocks in place, or hold them bS substantial interior meta] ties, world be superior to the wire wrapping above described. 4. Columns located in daxup placee shall receive a coat of a[ least one (1) inoh of Portland ce- ment mortar before application of Lhe fireproofing. 6. Columns made of steel or wrought iron pipe filled with con- crete shnll be protected by at lesst cue and one-half (P/z) inches oP fireproofing. G. Where the fireproofing of ool- mm~s is expoeed to damage from trucking or handling of merchan- dise, Lhe fireproofing shall bo jack- eted ou the autside Por a height of tint less than three (3) Peet from the seer with metal or other aIv proved coverfng. Section ll. °05. PROTECTION OF STEEI. GIRllh:R9 AND BEAMS. 1. The protection of Lhe webs and bottom flanges of girders and all members of trusses shall have a thickness of not less than two (2) inches at all points. The pro- tectiott of tits webs and bottom flanges of beams, lintels and all other structural members shall be not less than one mid one-half (1Y1) inches at any point. 2. If hollow clay rile be used fur protection, IIte lower flanges of beams and similar members shall be etleased either by lugs which form part of the skewhaeks and extend around the flanges meet- ing at the middle; or by rile slabs held in position by dove-tailed lugs projecting from the akewbacks. ]n either c2se care shall be taken to insure that all joints be solidly filled with mortar. Section 11.206. CONCRETF. PRO- TECTION for al] structural mem- bers shall be held in position by suitably designed interior steel au- chore hooked secw•ely around the flanges or angles of the met:there at intervals not exceeding eight (3) inches apart; these anchors shat] be not less than one-eighth (ys) inch in thickness if flat or one-tenth (1/10) inch in diameter if of wire, and shall be located at a distance not less than three- fourths (a/,t) inch, uor more than one (f)inch from the outside sur- faoe. Provision shall be made to prevent displacement of anchors while concrete is being deposited. When the flange width o[ steel members exceeds six (6) Inches, the wire used for anchoring the concrete protection shall be not loss than one-eighth (t/s) inch dia- meter. Section 11.207. STEEI. ANGLE OR CHANNEL STRUTS, or other structural framing ^ot elsewhere provided for, which are used Tor support in any wall, partition or i>tber cmtstruction, shall be 1h•e- proofed as required in this section, or in Section 11.'211, paragraph 4 of this Chapter. Sectimt 11.208. METAL PAN- ELS on the exterior oY buildings over one (1) story high shall be backed np or lilted in with masonry not less tl:an eight (8) inches thick. Soctipn 11209, MISCELLANE- OUS FIREPROOFING P R O V I- S1ONS. 1. UeYective or damaged fire- proofing maf erials shall not be need. Al] fireproof construction in- jured or damaged after being erected shall be repaired to the satisfaction of the Building IIv specter before any filling or finish is placed over same. 2. No pipes, wires, cables, or other material shall be incased within or embedded in the co- gnired fireproof protection of aa4 mints or other structrtral membm•s. 3 Ail meta] lath and plaster ceilings shall be supported by hangers or clamps attached to the floor m• root coustrnc[ion in an aUUroved manner. Such supports shall be oY such section and weight as will support the wet plaster without deserting more than mte- thirtieth (1/30) inch per foot oP span. 4. All atuddiug for metal lath partitions or wall furring shall be made from steel stock weighing not less than five-tenths (0.6) of a pound per lineal foot, shall bo spaced not over sixteen (16) inches center to tearer and shall be se- mtr~ly Gtsteued to the floor and ceiling construction. 5. Metal lath shall be of gal vanized steel weighing ^ot less thou fifty-four (64) ounces Uer square yard. Wire lath shall he not loss than No. 20 gauge, and sheet metal lath not less than No. 24 gauge. Metal lath shall be laced tc the supporting furring or studs at intervals not exceeding six (6) inches. Where lath ie bac)z-plas- Lered it need not be galvanized. 6. After fleece are constructed, no opening greater than two (`L) square feet shall be cut through them unless suitable metal Yram- ing or relnforciug is provided around the opening. After pipes or conduits are in place, al] open- ings around them shall be filled in solidly with fireproofing material unless approved close fitting in- dividual sleeves are Urovided. Section 11.210. PROTECTION ON' METAL 51'RUCTURAL MEM- BERS IN NON-FIREPROOF BUILDINGS. Steel girders and steel oc icon cohtmn5 whin] sup- port masonry walls, other than those facing upon a street, shall be protected by at least rive <2) inches of Hreproofing oP the same materials and a.pPLied in the mnrr ner specified horeiubefore for wall girders; or by two (2) inches oY meta] lath and cement plaster, the latter being applied in two (2) ]ay- ors wlih an air apace between them. AR other iron or steel col- umns shalt he Protected by at least one (1) inch of me[aL lath and cement plaster or its equivalent. The lath shall be of quality speci- fied in 6ectiwt 11.209, paragraph ~. of this Chapter. section 11.211. PARTIT10N5 1N F1RST CLASS Rti]LDINGS. 1. In fireproof bnildings, all par- titions enclosing public halls or separating the spaces occu Uied by different tenants, and all other per- manent partitious, shall be built not less than four (4) inches thick, oY solid or hollow brick, terra cotta, concrete or gypsum blocks or tile; m- not less than two and one-half (2t/i) inches thick of reinforced concrete or solid metal lath and cement plaster; or of such other incombustible materials a.nd thick- ness as shall meet the Standard Fire Testing for Partitions of the American Society for Testing Ma- terials. The required thickness 1'or block or file partitions shall be ex- clusive of plaster. All such parti- tions shall be securely fastened to the fireproof aonatruct.ion of the floor and ceiling. All bricks, blocks m' file shall ho laid with broken joints. 2. All partitions not enumerated above shall be of incombustible materials, except for woodwork permitted in Sectio¢ 3,200 of this Code. 3. All partitious in fireproofing bnildings shall be independently supported at each floor level, and where lateral support is not suffi- cient they shall bo stiffened by such steel reinforcement encased in the constnwtimt ae the Biulding ln- pector may require and aDProve. 4. Structural steel members necessary Pm• supporting a parti- timt, or for framing doorways or nth er openings through it, shall be protected by at least one (1) incl: oY flreproofinK. Cemmtt Ulaster, or cement-tempered plaster, may be aoceptcd for this purpose if prop- erly keyed. 5. Reinforced concrete Yor par- titions shall have n compreesive strength oP two ihmteand (2,000) pounds at twenty-eight (28) days. Olay file shall be porous or send-porous in quality, attd if hol- low shall have two cells in the thicknESS, with the thickness of shells inchtsive of plaster key tint less than three-fourths ('/ ) inch, and the thickness of ruche not less than five-eights (R/s) inch. The shells and webs or hollow gypsum m' concrete blocks or rile shall be not less than three-fmu'ths ('y4) inch. Gypsum shall be used only in dry locations. Metal lath and studding shall conform to the requirexnenta of Section 11.209 oC ^tis' Chapter. 6. If a stab hallway be con sidered as a part oY the stairway, and the latter is not separately enclosed as required by Sectio^ 11.600 of this Chapter, then the enclosing partitions for the hall- way shall be considered as the stairway shaft, and shall be en- closed wiUt masonry walls of eight (8) inch hollow concrete blocks, six (6) inches of hollow clay tile, or five (5) inches of rein- forced concrete. 7. If the partition surrounding a public ha!hvay be erected in ac cordance with the requirements for a fire exit partition, it may bo con- sidered as a horizontal exit for an ocmtpmmy equal to the area of the hallway in square feet. divided by three (3). Section 11.21L. FIRE-RESIS- TIVE PARTITIONS iN SEGOND ChASS BUILDINGS. 1. In Second Class non-fireproof buildings all partitions enclosing public hallways, or separating the spaces- occupied by different [en- 21 ants, shall either be built as re- quired in Section 11.211 of this Chapter, or they may be built of not less than three (3) inch up- proved solid or hollow partition or two (2) inch solid metal sGtd- ding and lath with cement plast- er, or by two by four (2x4) inch wooden studding with wood or metal lath and iln•ee-fourth ('/a) inch of cement or cement-tempered plaster on each side; or of any other matariala and thickness as shall meet the requirements of [he Partition fire test as pre- scribed by the American Society for Testing Materials for Fireproof Partitions. Wooden studs shall be set with four (4) inch dimension at right angles to the plane oP the wall. 2. All such partitions shall be fire-stopped the full depth oY the floor beams at each floor level by filling with tight-fitting brick or concrete or other approved means. 3. The principles governing hall- way partition omtstruction, as stated in Section 11.211, paragraphs 6 and 7 of this Chapter, shall ap- ply to the constriction of like partitions in nos`fireproof buil'd- ings-. Section 11.213 STEEL ROOF TRDSS PROTECTION. In lieu of the protection far steel members hereinbefore stipulated, a metal lath and plaster ceiling shall be deemed protection oC the truss members. 6ce Section 11.700 of this Chapter. Section 11.600. VERTICAL. OPEN- INGS. ^r al] First and Second Class Rnildings which are to be or are, used Tor any purpose other than a dwelling the stair walls, elevator shafts and all such openings con- necting i'rom one floor to another ahxll be enclosed by not less than eight (8) inches of brick or concrete blocks, or five (6) inches of rein- forced concrete, or six (0) inch- es of hollow clay tile, with aelf- cloaing or automatic fire doors pro- tecting all openings into such shafts. Section 11.600. WALL AND PARTITION OPE NLNGS. N'1RI7 DOORS ANll 9HUTTF.RS. Every exterior opening in all sides of firildings within the faro limits not abutting a street shall have motal- covered shatters or doors, con- strneted and arranged as apecilied in this Section, or in lien thereof may have frames and sashes oY hollow metal glazed with 24 R & S gauge wire glass not less thou one- fourth (',) inch thick, no pane in which shall be larger than twenty- fonr by thirty (24x30)inches. Rolling steel shurters may be used on the first story only. Fire doors and shatters shall be cmtstrncted of two (27 thiclmesses of matched boards not over six (0) inches wide, at right angles to each other, or crossing diagmtally, nailed with wire nails-, clinched, and securely covered with tin nn both aides and edges. sheet to be not larger than ten by fourteen (10x14) inches ip size, bat to- gether with tin roofers' lock joint xnd securely nailed, the nails to he driven inside the lap and the joints hammered dawn over the nail heads. No solder shall he used. Doors shall never he less than bvo (2) inches think. nor ahntl ers less than one and one-half (]. ~/a) inches thick. In tin-clad doors a vent hole shall he cuT tht•ongh one of the plates hear the, middle ttf fife exposed side oP the completed door or shutter. This vent hole shall have a dia- meter of tln•ee ($) or four (4) inches- bat shall not mtt Through t6n wood core. 'Phe plate armmd the wont hole shall be secured with small nails spaced mre (11 inch apart, and the exposed wood fl~nroughly painted. Hinges and hangers shall be of WPOlight iron and fa 9tP,lled to the, door or shatter with bolts. Latches shall be so arranged on shutters that they can be opened from either side. Swinging doors and shutters shall extend a.t least one (1) inch below top of sill, or they may close into the opening provided the wall be rabbetted mfg and mte-half (1~/z) inches at We top and sides and one (1) inch at the bottom. All sliding doors shall extend at least three (3) inches over the masonry at sides and top of door- way or opening, and efts (1) inGr below top of sill. Sliding doors may run at the bottom in a channel iron so set as to give rho door a bearing of one (Y) inch below the top of sill. Sills, except in exit doors in theaters, shall break the floor and rise at least oue (1) inch above floor level to prevent passage of flame and smoke, and be con- strneted of metal, masonry or con- crelo. Wood sills shall not be used. Rail or track Por eliding doors or shutters must be heavy enough to withstand heat without warping, and may be made of angle or chan- nel iron, mid both rails must be secured to wall whenever possible by bolts passing through the wall, otherwise expansion bolts shall be used Tn lien of channel or angle irmt, the track can be made of com- mon flat bar steel not less than three-eighths (3/s) inch thick and Year (41 inches wide. bolted through the wall with three-fourths fi) inch bolts or fastened with heavy expansion bolts. Binders shall be placed So as to prevent the door from rolling off the track at either omi, and also to hold it in position when rl oserl Section 17.700. CEILINGS. All ceilings, including basement ceil- ings, of Second Class Rnil dings shall be of lath and plaster, or other minimum equivalent flre~ resistive covering. If the base- ment is not to be occupied or used for storage, and only sufficient spare exists for ventilation, such ceiling need not be plastered. All suspended ceilings in First Class (mildings or ceilings protecting tress construction shall be plaster on mewl lath- Any opmrings in ceilin€e oP either First or Second Class buildings shall be carried through the roof with partitions Protecting the roof spare of not less than two (2) inches oC metal ;a*h and cement plaster, completely embedding the metal lath. Meta] lath shall be as described in Soa- tion 11.209 of this Chapter. The Poregoing does not apply to a coiling scnttlo, which shall be of fire resisLtng construction, includ- ing the frame. Section 11.810. WOOD SHIN- GLES. Within the Fire and in- dns[rial Districts the use of wood shingles m' other forms of combus- tible rooting other than felt tar and gravel is prohibited. Section 11.820. SKYiiCHTS. All skylights in buildings of classes one and two shall be of corrugated or prismatic wire glass not less than one-fourth (t/~) inch thick, set in a metallic frame. Section 11.830. PENT HOIISES. TANKS. ETC All stnrohtres hnilt mt the roof of buildfngs shall have 1:he walls, openings and roof con- strnetion and coverings in con- fm~mity with the requirements Pnr the remainder of the building. Provided, however, [hat ventilators and skylights may be made of sheet metal or sheet metal and wire glass with proper fire protect.imt in the interior shafts and screen or other protection nn the mrtsida to pre- vent the entrance of flying brands, and provided further that the walla and ceilings of pent houses to Sec- ond Class buildings may be meta] lath, plastered two (2) aides when such does not exceed eight (R) Pert in height. Section 11,900. FIRE STOP- PING. All partitions in Second and Third Class buildings shall be so constnicted that the top and bottom is sealed against fire by wood sills four (4) inches in thick ness at the top and two (2) inches iu thickuess at ffie bottom, or other aPproveG matter. In Second Class buildings the piaster shall be carried down be- low and up above the solid sills so as to form a tight covering, and to prevent fire eutering readily into the partition. Tight partitions of 1x6 T & G shall be placed in at tics over 1,000 square feel in area to art as a. fife stop in all third class buildings. Section 11-510. FLRE YIP E LINES. Every building of three (3) stm~ies or more in height shall have inside or outside oY the ex- terior walls one (1) or more meml- lic standpipes at least four (4) iuche5 in diameter, which shall ex- tend Crom four (4) feet above the sidewalk to and over the roof and rest on the fire walls, and at each story there shall be branches with three-inch (3") gate valves with reducm• from three (3) iuchos to two and one-halt (2 t~) inches, pro- vided with cap and chain; and there sha^ be a two-way Siamese inlet with two and one-half (2~/y) inch connection attached to each standpipe four (4) feet above the line oY the aidewallc, and a two- way outlet over the roof with Lwo (21 three-inch gate valves with reducer from three. (~7 Thanes Co two and onelralf (2 ta) inches, pro- vided with cap and chain. AlI hose confections to fit the standard connections of the Fire Department of the City of Hilo. All iron or steel material used in the construction and erection of standpipes ehail be galvaniaerl and shall be kept In good order and repair and free Erom any and all obstructions. ALI stamlpipes shall be capable oP sustaining a hydro9tafic preesnre of three hundred f300) pounds to the inch thronghmtt Iheir entire length after the same are erected. CHAPTER 12 CHIMNEYS AND HEATING APPLIANCES Section 12.100. CHIMNEY S AND FLIIES- All chimneys of masonry oC conm~ete construction shat] have walls at ]east eight B 1 inches @tick, or in dwellings may he constrneted oY four (4) inch brick walls with an inside lining of Cerra cotta or well-burnt clay Pipe not less than one (1) inch thick. No chimney shall be built on wooden brackets or enpports. No smoke pipe shall project through any external wall or win- dow except Plue pipes from gas burning water heaters or similar appliances. All chimneys shall have at least one (1) inch oC clear space be- tween the chimney masonry and any wood framing or wood con- struction of The building. NOTE: See also Chapter 16 of this Code. CHAPTER I3 SPECIAL OCCUPANCY PiROVISlO NS Section 13.100. THEATERS. AI] Ureaters hereafter built within the City of Hilo shall be of First Class construction provided, however, that they are in the Fire and Busi- ness Districts of the Ctty of Hilo, otherwise they may be of semi- flrst class construction. The Coun- ty Treasurer shall not issue a li- cense for any performance in any such building until a certificate in writing has been issued, signed by the Rnilding Inspector and fife Chief nP the Fire Department of Hilo mid/or the Deputy Fire Mar- shal, that the requirements of this Code have been complied with. Al] theaters shall have at least one (1) frontage on the street or on a right of way Yree to the pa- 22 trans of the theater and which right of way ie tort less than six- teen (16) feet wide which opens directly onto a street. lu such fl•ont there shall be suitable and ample means oY entrance and exit. There shall also be on each side of the exterior of the theater building an open court or spa.ae for use us a means of exit by Ure patrons oP the theater, each of }}vhich courts or apaees shall be not tens than eight (8) Yeet wide and shall extend Ure Ynll length of the building. These courts or spaces and rights of way shall be kept dear daring performances. Opening frorn the auditorium into Ulese COnrta Or 3paee8 The]'e Bhall be not less Uran two (2) exits from each floor and each gallery; these openings shall be closed by doors Caslly Opened by pr08aUPe frorn the incide during all perform- ances. They shall be of ample width and shall awing outward in such a way as not to block the balcony upon which they open. A11 such exits moat be open from Lho aisles. The exterior balconies upon which these exits open, and the stairways leading W the ground, must be not less than four (4) feet wide, and shall be constructed of iron, steel or other noncombnetible cmrsU~nction of ample strength to eaYoly sustain a load oT one lunr- dred (100) pounds per square foot, with a factor of safety of tour (4). There shall be also one (1) exit on each side of Lhe stage into the courts or spaces. At each and every exit in anY t.heator in the Oounty of Hawaii (here shall be placed and main- tai~ed a ]amp in which only min- eral, nni or other ]ow flash oil, or electricity upon an independent circuit shall be used, and said lamp or lamps shall be lighted Pre- vious to the opening of the doors oY such theater for any perCOrm- auce therein and shall be ke U' lighted until the audience shall have departed from the premises, and there shall be inscribed upon said lamp or ]amps the word "Exit" in din Lnctly visible letters oat less than six (6) inches high. Stairways shall have handrails on each side firmly secured to strong supports or to Lhe walls. 'Phero shall be no filght of more Lhan twenty (20) steps, there shall he no winders, and no step shall he lees than four (4) feet wide iu the clear. Such steps shall have a rise not greater Lhan xis (,) inchos and a tread not less throe fen (10) inches. There shall be a fire wall of hriek m• reinforced concrete above the prosemrinm arch and between the eta ge an rl the a.u ditorin m, which wall shall extend at least three (3)- feet above the roof. Tho proe- cmrium shall be Lhe only open- ing in said wall above the love] of Lhe stage, and all openings through this wail below the stage level shall be provided with self-clos- ing flea dom~s, constructed as pro vided in Section 11.600 of this Code. The wall above the pros- cenium arch shat] be supported by reinfmrced concrete girders or by steel girders covered with flee proof material, or other approved construction. The prosemrirrm opening shall be Drovided with a curtain of asbes- tos or fireproof material, sliding at each end in grooves securely fastened to the masonry wall, and extending into nude grooves to a depth of not Iese than forte (4) in ch es. The fireproof mvtain may. h m~-ever, he fu rniah ed with steel cable ;;aides not less thaw one- rprarter ({y) inch in diameter; Pro- vided, that such sort sin lops over Tho stage opening at the sides and toD for a distance of not less than eight tS) inenes, and that attached to said certain at the top and bot- tom, to fell wid Lh thw•eoF, shall 6e wrought irou or steel pipe or other approved stiffeners of not less than one and one-fourth (ll/s) inches diameter. Tho fireproof mu•Lain shall he kept lowered between acts, during intermissions, and at Lhe colsa oY each performance, except during rehearses. The curtain shat bo hang not nearer to Lhe footlights than throe (3) feet. All seats except Lhoae in Lhe boxes shall be firrnly fastened to Lhe, floor, and no seat in the audi- Lm~ium shall have more Lhan seven (71 seats intervening between it and any aisle adjacent Seats shall not be less than thirty-one (31) inches from back to back, nor less than twenty (20) inches in width, center to center measnremente. Center aisles apd passagowud's shall be at least forty-eight l4S) inchos wide at [he narrowest point. side aisles at least thirty-six (36) inches, and all shall increase in width toward the point of exit at Least one-quarter (l!r) inch for each foot of length. 1'he grade oP aisles shall not be greater Lban one and rote quaeter (1'/) inches per Loot. A ventilator shaft of capacity equivalent in area to the skylights hereinafter mmrtioued, lined with fireproof material, shall be placed over Lhe canter of the stage and shall extend at ]east three (3) Peet above the roof. The rrof over the stage shall be provided with sky- lights in area equal to one-fourth (~/ 1 of the stage area, and said skylights shall be made In open automaticely in case of fire. Theater flows shall be oP sufil dent strength to support an im- posed live Load of one hundred (100) pounds per agaare foot. }9very theater shall bo ognipped with at leas[ two (2) lines of ataud- arrl throe-inch (3") cast irou or galvanized water pipe, leading di- rectly ITOm the street main, and provided with Lhe standard coupl- ing of the yire Department, wiUr noC less than twenty-five (25) feet of hose attached. Such water pipe and hose shall bo ready for imme~ dia'e rise ut any Utne during Lhc pm'Yormance in said building. The surge area, above and below. shall be eqn ippad r-ith amomeic sprink- lers as Provided by Chapter 10 of this Code. EIecU•ir, wires, fooli gh is and all apparatus Car extinguishing fires or guarding agepst Ure s.une shall bo in charge of and under rho cmr- h-ol of the Fire Deparmreut, and the Chief of said Department shall be responsible for the esemr(ian and enforcement oP this regulation. Gradients or inclined plmrea shall bo oxnploYed instead oY steps to overcome slight difference of IeveL in or between aisles, corridors and passages. Walls separating the actors' dressirg rooms tram Ure stage and Partlfions dividing the dressing rooms, together with partitions of every passageway front the same to the stage, and all partitions ou or abort the stage, shall be cam strutted of fireproof materiel. A^ shelving and cupboards i^ sash and every dressing room, property room or storage room shall be emr- structed of 8reprooP material. Dressing rooms may be placed in the 8y galleries, provided that proper exits are secured therefrom to fire escapes in the open courts and the ata;rs loading [o the carne shall be GreprooP. Dressing some shall have an independent exit, loading directly into an open coma or street, and shall be von tilal ed by windows in the externs.] wall; and no dressing room shall be more Uran rote (1) story below the street level. All windows shall bo ar- ranged to open, and nano oC the windows in outside walls shalt have fixed sashes, irmr grills or btvs. Moving picLnre machines shall be enclosed in fireprooT booths, with a fireproof ventilator and sediclon- ing fireproof do~:rs and shutters opening into the theater. II fmy arrangenrellt Or Con attar tiou or appltance of any theater ;e unsafe to 11Ce, full authority if: hereby vested in the Fluihling hr specter and the ChieY of Ure Fire llepart.ment, or either of Lhem, to order and entm•ce such changes or ad di[ious as may he necessary. Sectimr 13.200. MOVLNG Pl('. TURF HOUSES. ]hrild ings ont- sitle the fire ]i Writs. which contain no balavdes and only a small stage and little or no movable scenery, may be Semi~Fird. C!aas and or Second Glass bnildin K5. Snrh build- ings shall have exit facilities, mov- ing' picture booth cons4~netlon, exit lights, seats arraug~ement and spac- ing, doors opening outward with seli'- release bars, floor gradients, aisle spacings, unobeLruc(ed passages and outside passage a.rcas the some as required for theaters provided in Sectimr 13.100 of this Chapter. hi addition, fire extinguishers cr hose lines shall be provided as deemed necessary by the Ruild inK ]nspec- tor and the Chief of the Fire De- partment, or either of them.. Section 13.300. PS.ACN:S OF 1NSTR UCTION. No school or place of inslrnetiou over rote (1) story in height ahedl be of Th h~d ['.lass construction. Second Class buildings constructed Ear this pur- pose shall have exits so arranged that no matter in what portion of the building fire might occur, a.L least one (1) exit shall be acces- sible. No Second Class bniidiug 3'or the shove use shall exceed two (2) stories in height. Section 13.30Y. I2EFRIGER9- TCON PLANTS. All refrigeration plants which employ ammonia or other tonic gas as rho refrigerant shall he so emrstrncted Ura.t the entire ammmria system may 6e flashed into Ure sower or other approved disposal receptacle Iry control valves outside the bnild- ing~in case of fire or break in rho linos. CHAPTER 14 ELEVATORS Section 74.000. ELEVATORS. The term "elevator" as used in this Code shall inchrde all elevators or lifts used for carrying passengers or freight. The term "dmnb waiter" shall include such special form of ele~xtor the dimensions of which do not exceed ais (6) sgnaro feet in horizontal Sectimr and forte (4) feet in height, and which is used Yor the conveyance of smal packages and merchandiec. Auy baud-power elevator having a rise of less Lban thirty-five (36) i'cet need not comply with all the roginrements o[ this sectlon. No bolt driven from a countershaft shall be installed Yor passenger ser- vice. Suction 14.010. APPL1CATfON FOH INSTALLATION OR Af. TERATIONS. Before any elevator shall hereafter 6o installed or altered ill any buihling, the owver shall submit, on appropriate blanks Ilrrniehed Iherefm•, to the 73 wilding Inspector an application 1n dupli- cate stating Ure construction and mode of operation of such elevator [o be installed or altered, accom- panied by such plans and draw- ings ae may be necessary and shall obtain his approval therefor. Be- fore arq' such elevator shall bo put into service, the same shall have been duly tented and iuspecied by the Brtilding Inspecfor and a cer- tificate of inspection and approval obtained. hr makhrg :my changes ur altnratione to elevator shaYta. rails, overhead machinery or power. all the work changed m• altered shall be made to ono form to these rc;gulaUOns. Section Y4.02U. C A P A C I T Y PLACE. The owner of any eleva- tor nom in operation and Ure manu- facturer of mrY s~.rch elevator herr.- aftnr placed in any building shall 23 _~. ~_ cause to be fastened. in a con- spicuous place in said elevator a metal plate having suitable raised letters on same which shall designate the number of pounds which said elevator shall be per- mitted to carry, but in no case shall a carrying capacity of less thin one hundred (100) pounds per square foot of platform area inetge Lhe car be permitted on any pas- aetlger eleVntOr. Section 14.030. OPERATOR. Every elevator, except full auto- matic push butt mr eleva[ore, shall be in charge of a competent, re- liable operator not less than eigh- teen (18) years of age, who shall have had at least one (1) week's experience In funning aR elevator wtder the constant supervision of a person who has received a .cer- tificate of competency as an eleva- tor operator. Section 14.040. OPERATOR TO REGISTER. No person shall run any passenger or freight elevator in the County of Hawaii ^nleas he shall first register at the office oC the Building inspector his name and residence, also the location of the building in which he is to perform such service, and shall first re- ceive from the Building Inspector a certificate of competency. Section 14,060. DOORS. Not more than one (1) door opening in the elevator shaft shall be allowed on each floor, and all openinKS in the several stories shall be one above the other, except where the operating device of Lhe elevator is so placed that the operator eau readily control a.ll doors without leaving the car control, in which case more than ate door opening may be permitted on a floor. Section 14,060 SAFETY DE- VICP: ON llOORS. Al] elevatm-s hereafter installed in vertical shafts shall be controlled by a mechanical device that will automatically pre- vent the car beinK moved until the shaft door or gate at which the car is standing is abut and securely fastened, and which will prevent the opening of any shaft door m' gate until the car has come to rest at the landing. All doors- m• gates opening into existing elevator shafts shall be locked or bolted in a manner to Permit opening only by the operator of the car. Section 14.U70- C O U N T F. R WEIGHTS. All rounter weights shall have their sections etroagly bolted together. There shall be not less than three 13) feet clenr- auce between the top oY counter weights and the under side of over- head beams when the car is resting ou the bumpers. No rontimious forged sG•ips shall be Permitted mt rottnter weights. 6ection 14.080. 1NCOMBGS'L'- IBLh'. CONSTRCCTION. Elevator cars shall be constructed of in- combustible materials, except that. flooring may be of hardwood. There shall he not more than one and one-fourth (ll/n) inches space between the floor of the car and the floor saddles, and whore the saddles project into the abaft the same sha.il be properly beveled on the under side The under side oY the car shall be of incombustible materials. Cars for al] elevators shall he properly lighted. Section 19A011. GUIDN: RAILS. All guide rails for both car and emmtm• weights shall be of steel, soil shsl] he bolted to the sides of the shaft with steel or cast iron brackets. so spaced that the guide rails will be rigid. The splices i^ ^te rails shall be located as near such rigid supports as possible. Section 14.100. COMBINATION FREIGHT AND PA6SENGER ELEVATOR PROHIBITED. No passenger elevator shall be Per- mitted to have a freight oompar4 ment attached to it in any manner. Section 14.]10. GRATING UN- DER SHEAVES. Immediately un- der the sheaves at the top of every elevator shaft in any building there shall be provided a concrete slab or substantial grating of steel hav- FnK tmt more than one (1) inch space between the members of said grating, and of such conetrartion as shall be approved by the Build- ing Inspector. Sectiou 14.120. CLEARANCE, TOI' AND BOTTOM. A clear space of not less than three (31 feet shall be provided between the bottom of the shaft and Lhe lowest point of the under side of the car floor when the car is at its lowest landingl and between the top of the crosshead of the car and the under aide of the overhead grating when the car is aC its top landing: except that this latter space shall be not less than five (5) feet for elevators having a speed in excess of three hundred and fifty (360) Peet per minute, and may be reduced to two (2) feet for elevators having a total rise not exceeding thirty (30) feet, and a speed not exceeding cue hundred (100) feet per minute. Section 14.130. INCOMBUST- IBLE PARTIT1ON5. Al] parts of Lhe elevator machinery shall be enclosed by suitable partitions of incombustible materials, and such iuclosures shall be lighted. Free and safe access shall be provided to all parts of elevator machinery. Where Lhe machinery is located at the bottom of the shaft tt shall be protected with a substantial pit pan. Sectiou 14.190. BUFFER SPRINGS. At the top and bottom of al] elevator shafle there shall be placed substantial springs Yor ca.r and counter weights. Section 14.150. CAYACFTY OF STICECTURAI. SUPPORTS. The carrying beams and other supports for all machinery shall be of steel designed for double the live loads to bo supported. Sectiou 14.160. TRAY DOOR IN CAGE. Every passenger elevator shall have a. trap door in the top oP the car of such size as to afford easy egl'esa for pa8sellgel's, or where rive (2) cars are in the same shaft such means of egress may he provided in Lhe side of each car. Section Y4.170. INSPECTION. The Building Inspector shall cause an inspec time oC elevutm•s carrying passengers or employees to be made at least once every three f3) tnmrths, and shall require any nec- essary repairs to be made promptly by the owner. If the Building ht- apector at any time considers an elevator to be unsafe, he may re- quire its operation to cease until such repairs or alterations have been made as will in his judgment produce safety. L~ lieu of each inspection by his own Department. Ute Building Inspector may accept the written report of inspection made by other reliable and proper- ly constituted persona which in his judgment are competent and satis- factory and have been approved as such by the Board of Supervisors oY the County of Hawaii. Section 14.180. ELEVATOR FOI; FIRE DEPARTMENT. In every building exceeding one hundred (100) feat in height at least one (1) passenger elevator shall be kept in readiness, without opera- tor, for immediate nee by the Fire Department during all hours oY the night and day, including holi- days and Sundays. Section 14.150. SAFETY DE- V1CF,S. IL shall be unlawful to use any elevator that is not pro- vided with saYety devices for bring- ing the elevator car to rest with- out serious injury to passengers m• operator whenever it may for any reason exceed its rated speed by more Lhan forty (40) per cent or reach a speed of eight hundred and fifty (860) feet per minute. Safety devices are ^ot required upon the plunger type of elevators, nor upon sidewalk elevators which travel leas than thirty (30) feet. NOTE: Chapter 16, covering the plumbing provisions of this Cade, will be found in Ordinance No. 101. CHAPTER 16 HEATING Section 16.100. SMOS{E-STACKS. Smoke stacks connected to steam boilers under which sawdust, shavings or wood are burned shall extend not less than twenty-five (26) feet above the roof oC any ad- jacent root, 2nd shall be provided with an approved spark arrester. Sec: Lion, 1G,200. R,ANGE9, OVENS AND S1MIi.AR DEVICES. Wooden flom~s under ranges, ovens, kilns, coffee roasters, candy kettles and similar devices shall be pro- terted by a sheet of asbestos not less than mre~aixteenth (1/16) inch in thickness covered by a sheet of metal not less than twenty-fate (24) gauge extending one (1) foot beyond the base of such device. A layer of properly cemented brick or file may be used in lieu of the above. Section 16.300. BOILER ROOMS. All walls of boiler rooms situated within Fire Districts Nos. 1, andL shall be of masonry, concrete or terra cottta Yor their full height and the roof shag be of corrugated iron or concrete or asbestos or other similar coverinK. If there is a ceiling it shall be oP metal, as- bestos or plaster on meta] lath. Openings into a boiler room as above described shall have fire doors or shutters, constructed ae specified in Section 11.G00 of this Code, arranged to close automa- tically; and where oil 1s burned under gravity Peed, every doorway shall have a masonry, concrete or terra cotta sill rising not less Lhan eight (8) inches above the floor. No wood or other inflammable ma- terial shall be used iu the construc- tion of the Boor of any boiler room. Boiler rooms outside Fire Dis- tricts Nos. 1 and 2 may be oou- atructed of uon-combustible ma- terial Dvery boiler room whore shavings or other refuse are used Tor fuel shall be provided with a stand pipe connected to a Sre or water main not less than one and one halt (1'Ra) inches in diameter lo- cated near the door, with at least twenty-five (25) feet of one and one-halt (lt/r) inch hose attached thereto. Section 16.301. CHIMNEYS. All chimneys shall be constructed in conformity with the current edi- tion oY a Standard Ordinance for Cbimney Construction recommend ed by the National Board of Fire iJnderwriters and/or as required by Chapter 12 of Chia Code. Note: Chapter 17, covering the electrical provisions of this Code. will be Pound in Ordinance No. 100. CHAPTER 18 SIGNS AND BILLBOARDS Section 18.100. SIGNS WITHIN THE FIRE LIMITS. No wood, canvas or other inflammable sign shall be permanently erected with- in tbe~ fire limits. Temporary per- mits not to excewl ten (10) days ma.y be issued by the Building ]n- s-per.tnr if such is also approved by the Chief oP the Fire Department. Section 13.200. SIGNS IN ALf. DISTRICTS. No sign shall project over the public ways more than three (3) feet. Such projecting signs shall be structurally secure and shall allow at least seven (7) Peet passage below. Section 18.300. SKY SIGNS. Sky signs erected on the roof oP buildings and other exposed planes shall be entirely of metal and non- 24 combustible material excepting necessary wire insulation. No sky sign shall project beyond the build- lug and shall not exceed twenty (2U) feet in height, nor shall be nearer the edge of the building or structure than fifteen (15) feet, and shall be designed for a wind pres- sure in any direction oP thirty (30) pounds Per square foot of exposed area. Section 18.400. BILLBOARDS. All billboards erected shall be sub- stantially built and the permit ap• plicatimt therefor shall be accom- panied by the written consent of the owner, and if under lease, by both the owner and lessee. CHAPTER 19 FIRE EXTINGUISHING E(3UIP- MENT Section 19.100. FIRE EXTIN- GUISHERS. Wherever fire extin- guishing equipment is required, whether hose lines, chemical tanks or smaller equipment, they shall contain thereon the approval stamp of the Underwriters' Laboratories and shall be subject to regular in- spection by the Chief of the Fire Department, who may order their recharging, arrangement or any other reasonable regulation deem- ed necessary. Hose lines shall be on mains carrying the city pressure at the hose end in the City of Hilo and Tor other districts shall be con- nected to an a.pProved water sys- tem and supply. Sectimt 19.200. SPRINKLER RF.42UIREMF.A'TS. 1. In all new or existing build- ings within the District of Hilo where additional area is to be al- lowed any building by the installa- tion of a sprinkler system, such syetoxn shall be au approved auto- matic aprinler system, so con- structed ae Co protect every square foot of floor area. 2. Only approved sprinklers shall be used i^ automatic sprink- ler systems. All fittings, valves, and wnnections used in sprinkler systems shall be of an approved tYPe. 3. Sprinkler heads shall he so placed as to thoroughly Protect all parts of the space to be pro- tected, but not ovor one hundred (100) square feet oP area for each sprinkler head. 4. The size of pipe risers and laterals to serve sprinkler heads shall not oxceed the following; unless same meets with the ap proval of the authorities oY the Iocai jurisdiction; Maximum Number oP Sprinklers Allowed 1 sprinkler 1 2 sprinklers 3 " ., 10 ' 20 " 36 55 " fl0 140 6 200 " Size of Pipe ?!s inch 1'b „ 1'Fi ., 2 '• 2 ~~ „ 3 " 3'Fl ., 4 " 5 „ 5. Each system shall be provided with an outside screw and yoke gate valve so located as to be readily accessible and to control all sources of water supply to the system, except that for fire engine connections. Drain pipes shall be provided and the system so in- stalled as to drain all Parts. 6. All systems shalt be wet pipe. 7. Presspre tanks, if used, shall have a total capacity oY not less in any event than four thousand flue hundred (4,500) gallons (3,000 gallmis of water) and in any event the tank shag have capacity to supply twelve and one-half (12~/z) Per cent a[ the greatest number of sprinklers within a fire area on any one flom•, for twenty (20) minutes with an average dis- charge of twenty (20) gallons per minute per sprinkler. S. Gravity tanks, if used, shall have a capacity of not less than five thousand (5,000) available gallons or twice the sprinkler ca- pacity of preceding paragraph. 9. Fire pumps, if need, shall be of not less than five hundred (500) gallon capacity per min- ute and sufficient to supply fifty (60) per cent oY the number of sprinklers within a fire area on any floor with as average discharge per sprinkler of twenty (20) gat- lons a minute. Pump to have an adequate source of power sad be supplied from street main or from well or cistern containing one hour's full supply for the number of sprinklers judged to be open by fire a[ any mre time; auction piping to be well installed. 10. The system shall be con- nected to Siamese steamer connec- tion outside of the building by a pipe of diameter equal to that of the largest standpipe supplied, un- less otherwise approved as in pa- ragraph 4 of Chia Section. Such connection shall be made on each street front, except that corn- er buildmga having one street frontage of leas than fifty (60) feet may have only one (1) connection. Siamese connection shall be about two (2) feet above the curb level, and shall be provided with check valves, and substantial caps to protect thread on the connection; the thread shall be uniform with that used by the local Fire Depart- ment. A suitable iron plate with raised letters shall be provided, reading: "TO Basement Sprinkler" or "To Cellar Sprinkler" or "To Cellar Sprinkler;' where only these are installed, or "TO Automatic Sprinkler" where entire building is equipped. 11. Piping shall be wrought iron or steel sad maybe galvanized when conditions require, and to- gether with fittings and connections, shall be of such strength as to safely withstand at least 150 Pounds wa- ter pressure to the square inch for two (2) hours when ready for ser- vice, without leaking at joints, valves or fittings. Such test to be made in the presence of the Chief of the Fire Department. 12. All such sprinkler equip- ments shall be in strict accord- ance with the current regulations of the National Board of Fire Un- derwriters for the installation of Sprinkler equipments. CHAPTER 20 Section 20.100. Ordinances Nos. 46. 51, 54, E9. i3 and 80 of the County of Hawaii and all other amendments thereto are hereby re- pealed. Section 20.150. If any section, sub-section, sentence, clause or phrases of this Code is, for any reason, held to be unconetitntional or invalid, such decision shall not affect the validity oY the remain- ing pm•[ions of the Code, the Board of Supervisors hereby declaring such approval irrespective of the fact that any one or more other sections sub-sections, sentences, clauses or phrases be declared un- constitutional or invalid. Section 20.200. This Ordinance shall take effect from and after the date of its approval. Introduced by (SgdJ JULIAN R. YATES, Supervisor from the 2nd Represen- tative District. Date of Introduction: July 8, 1932 Hilo, Hawaii. Approved this 4th day oY Febru- ary, 1933. (SgdJ SAMIIEL M. SPENCER, Chairman and Executive Officer, Board of Supervisors County of Hawaii. TERRITORY OF HAWAII) COUNTY OF HAWAII ) SS. I hereby certify that the fore- going Ordinance was regularly con- sidered at a meeting of the Board of Supervisors of the County of Hawaii, held at the County Seat upon the 4th day of February, A. D. 1933, and upon being put to vote said Ordinance was adopted by a majority of the Supervisors at said meeting. IN WITNESS WHEREOF, I have hereunto set my hand and affixed the seal of the County of Hawaii upon this 4th day of February, A. D. 1933. (Seall (Signed) ALFRED KUMALAE, Deputy Clerk of the County of Hawaii. L5