Loading...
HomeMy WebLinkAboutORD 1967-060' ~ ~. ~~~ ~: ~~ COUNTY OF HAWi-II - STE?TE OF H,~1?d_-III ORDIN/,NCE N0. 6G ~- %'id ORDINANCE REL°TING TO THE ESTr!BLISHING OF RULES APID REGULATIONS FOR THE PLUMBING PND DRAINAGC OF BUILDINGS COUNTY OF HAW[`.II, STATE OF HAia'<1II; LICENSING IN THE COUNTY OF H.'~W;'II, ',Vfl REPEALING OF ALL SECTIONS ~PID OF Hi'WAII IN CONFLICT THERr:r?ITH. ''AND THE CONSTRUCTION OF HOUSE SE?dERS IN THE PROVIDING FOR THE E}L':NtINi+TION, REGISTRATION, PND PRESCRIBING PENP.LTIES FOR THE ORDINANCE, ?s`,RTS OF SECTIONS OF ORDINANCE OF THE COUNTY BE IT ORDPSNED BY THE BOARD OF SUPERVISORS OF THE COUNTY OF Firm^7!',II: SECTION L That certain plumbing-; code known and designated as "Western Plumbing Officials Uniform Plumbing; Code, 1964 Edition'' as copyrighted and published in lgo4 by the ?^lestern Plumbing Officials -4ssociation, is hereby adopted by reference, subject to the amendments hereinafter set forth, and shall be kno4m as the "Plumbing Code," and cited as such, and referred to herein as "this Code," and to provide for the examination and registration of persons enga+;ed in the business of plumbing or laboring at the trade of plumbing, the issuance of permits and for the collection of fees; to create an adminis- trative office and e board of plumbing examiners and prescribing their duties; to establish minimum regulations for the installation, alteration or repair of plumbing and drainage systems and the inspection thereo'; defining certain terms; and providing penalties for the violation of the provisions thereof. SECTION 2. 'emend Section 1.1 to read: "Sec. 1.1 -- :"dministrative !'nxthority "t^Ihenever the term ' dministrative iiuthority' is used in this Code, it shall be construed to mean the Chief Engineer of the County or hi.s authorized representative.' SECTION 3. Amend Section 1.2 to read: "Sec. 1.2 -- Assistants "G?henever the term 'assistants' is used in this Code, it shall be construed to mean the authorized representatives of the f-dministrative !`uthority." SECTION 4. Amend Section 1.3 to read: "Sec. L 3 -- Department HavinE; Jurisdiction OeL ^~ b O File yw 1L L 1iw D~t« "Unless otherwise provided for b,y law, the Department of Public Works shall have jurisdiction over and administer all matters covered by this Code." SECTION 5. C'.mend Section 1.7 to read: "Ser_. L 7 -- Violations and Fena.ities "Any person, firm or corporation violating any of the provisions of this Code shall be deemed guilty of a misdemeanor and upon conviction thereof shall be punishable by a i'ine of not to ex;eed Five Hundred Dollars (~i500.00). Each separate day or any portion thereof during which any violation of this Code occurs or continues shall be deemed to constitute a separate offense, and upon conviction thereof shall be punishable as herein provided. "The issuance or granting; of a permit or approval of plans and specifications shall not be deemed or construed to be a permit for, or an approval of, any violation of any of the provisions of this Code. No permit presuming to give authority to violate or cancel the provisions of this Code shall be valid, except insofar as the work or use which it, authorizes is lawful. "The issuance or „granting of a permit or approval of plans shall not prevent the [-administrative Fauthority from thereafter requiring the correction of errors in said plans and specifications or from preventing construction operations being carried on thereunder when in violation of this Code or of any other ordinance or from revoking any Certificate of Approval when issued in error. "Every permit issued by the flministrative ^.at;hority under the provisions of this Code shall expire by limitation and become null and void, if the work authorized by such permit, is not commenced within. sixty (60) days from the date of issuance of such J;ermit, or if the r,~ork authorized by such permit is suspended or abandoned at any time after the work is commenced for a period of sixty (60) days. Before such work may be recommenced a new permit shall be first obtained to do so. - 2 - "No permit shall be required For work relatir.; to installation of non-potable water lines on farms and ranches provided that the provisions of Sections 1002 and 1003 of Chapi.er 10 of the T•]estern Plumbing Officials Uniform Plumbing Code are complied with." SECTION 6. Amend Section 1.10(a) to read: "Sec. 1.10 -- To .?hom Permits May Be Issued "(a) No permit shall be issued to any person to do or cause to be done any plumbing or drainage work regulated by this Code, except to a person holding a valid unexpired and unrevoked master plumber's Certificate of Qualification or Registration as required by Section 2.2 or to a public utility supplying gas to the public and licensed to distribute such has in the County, for the installation of ryas piping systems and other related appurtenances, provided that a master plumber shaLL sign a permit issued to a firm or corporation for which he is employed or for his own account if engaged as a sole proprietorship and for no other, and a permit issued to said firm, corporation, or sole proprietorship; provided further that said master plumber shall not sign and not be issued a permit for any other firm, corporation, or sole proprietorship although said master plumber may be employed by any other i'irm, corporation, or sole proprie- torship or be enf;aged on his own account." SECTION 7. «mend Sectior. 1.12 to read: "Sec. 1.12 -- Cost of Permit "Every applicant for a permit to install, add to, alter, relocate or replace a plumbing or drainage system or part thereof, shall state in writing on the application form provided for that purpose, the character or work proposed to be done and the amount and kind. in connection there- with, together with such information pertinent thereto as may be required. "Such applicant shall pay for each permit issued at the time of issuance, a fee in accordance with the following schedule, and at the rate provided for each classification shown therein. -3- ".`any person who shall commence any plumbint~ word for which a permit is required by this Code without first havint~ obtained a permit therefor shall, if subsequently permitted to obtain a permit, pay double the permit fee fixed by this section for such work., provided, however, that this provision shall not apply to emergency work when it shall be proved to the satisfaction of the Pdministrative Authority that such work was urgently necessary and that it was not practical to obtain a permit therefor before the commencement of the work. In all such cases a permit must be obtained es soon as it is practical to do so, and if there be an unreasonable delay in obtainin; such permit, a double fee as herein provide3 shall be chary=,ed. "For the purpose of this section a sanitary plumbing outlet on or to which a plumbing fixture or appliance may be set or attached shall be construed to be a fixture. "When interceptor traps or house trailer site traps are installed at the same time as o building sewer on any lot, no sewer permit shall be required For the connection of any such trap 'to an appropriate inlet fitting provided in the building sewer by the permittee constructing such sewer. "When a permit has been obtained to connect an existing building or existing work to the public sewer or to connect to a new private disposal facility, backfilling of private sewage disposal facilities abandoned. consequent to such connection is included in t;he building sewer permit." SECTION 8. amend Section 1.13 to read: "Sec. 1.13 -- All 1^Iork to be Inspected. "f.ll plumbing and drainage systems shall be inspected by 'the Administrative r.uthority to insure compliance caith all the requirements of this Code." SECTION 9. <^,mend the schedule of Pees, appearing after Section 1.13 to read: - ~+ - "Schedule of Fees For issuing each permit. $ 1.00 In addition, for other than Government projects, fees for the installation of fixtures, etc., For each house sewer. 2.00 For each plumbing fixture or trap or set of fixtures on one trap 1.00 For retesting of existing plumbing and~or gas system in relocated building 1.00 For repair or alteration of waste or vent piping 1.00 For installation or alteration of water piping and~or water treating equipment . 1.00 For lawn sprinkling system including backflow protection devices 1.00 For each waste interceptor or equipment including sewage ejector 1.00 For vacuum breakers or backflow protective devices installed subsequent to the installation of the piping to special fixtures or equipment served, including the necessary water piping 2.00 For each water heater and~or vent 1.00 For each domestic or commercial gas appliance. including the piping; system 1.00 For other gas piping system or temporary system 1..00" SECTION 10. Amend Section 2.1 to read: "Sec. 2.1 -- Definition of P1_umbers and Contractors "(a) A Master Plumber is a person who has had issued to him a valid Master Plumber's Certificate of Qualification pursuant to the provisions of this Code. "(b) A Journeyman Plumber is a person who has had issued to him a valid Journeyman Plumber's Certificate of Qualification pursuant to the provisions of this Code. "(c) A Plumbing Contractor is a person who possesses a valid Y~laster Plumber's Certificate of Qualification and conducts, carries on or engages in the business of plumbing from a legitimate place of business or shop pursuant to the provisions of this Code. "(d) An Apprentice Plumber is a person who labors at the trade of plumbing as an employee under the direct supervision and in the immediate presence of a plumbing contractor or journeyman plumber." -5- SECTION 11. Amend Section 2.2 to read: "Sec. 2.2 -- General Provisions "(a) It shall be unlawful for any person or persons to labor at the trade of plumbing in the capacity of a master or journeyman plumber without first having had issued to him a valid Plumber's Certificate of Qualification or Registration by the Board of Plumber Examiners. "(b) It shall be unlawful for ary person, persons, firm or corporation to conduct, carry or engage in the business of plumbing, display or expose a sign having similar import for the purpose of implying the advertiser to be so engaged or act in the capacity of a plumbing contractor, without first having had issued a valid Master Plumber's Certificate of Qualification or Registration b,y the Board of Plumber Examiners and operate from a legitimate place of business or shop in an area or areas zoned for such purposes." SECTION 12. Amend Section 2.4 to read: "Sec. 2.4 -- Board of Plumber Examiners "The Board of Plumbing Examiners shall be under the Department having jurisdiction provided for by law and unless otherwise provided for shall consist of three (3) licensed master plumbers who shall have had not less than six (6) years experience in their respective trades. They shall be residents of this County for not less than one (1) year and citizens of the United States. "Said Board shall be appointed by the Chairman and Executive Officer of this County and confirmed by the members of the Board of Supervisors. They shall serve for a term coterminous with the term of the Chairman and Executive Officer and any member may be removed from office sooner, for cause, by the Chairman and Executive Officer with the approval of the members of the Board of Supervisors. "The Administrative Authority and the Plumbing Inspector shall have a voice but no vote in the proceedings of the Board. The Administrative Authority shall provide a secretary for the Board. A quorum shall consist of three (3) members." -6- SECTION 13. llmend Section 2.5 by adding at the end thereof subsections (e) and (f) to read: "(e) The Board of Examiners shall hold two (2) regular meetings every year, one (1) during the 'first half and the other during the last half of the year, and special meetings at other i;imes when necessary, at the call of the Chairman of said Board. They shall during said regular meetings and any adjourned meeting thereof, conduct regular written plumbing examinations for the purpose of determiciing the competency and knowledge of plumbing and drainage work and Department of Health sanitary regulations, of persons whose applications have been approved. "(f) For each regular meeting however long and for each adjourned meeting and special meeting lasting more than two (2) hours, each member present other than ex-officio members, shall receive Ten Dollars ($10.00) for each meeting attended but not more than Fifty Dollars ($50.00) in any one month." SECTION 14. Amend Section 2.6 to read: "Sec. 2.6 -- Application Fee "Every person applying for a Plumber's Certificate of Qualification or Registration shall pay to the secretary of the Board of Plumber Examiners at the time he makes such application the following fees: (a) Application for Master Plumber's Certificate $10.00 (b) Application for Journeyman Plumber's Certificate 5.00." SECTION 15. Amend subsection (b) of Section 2.7 to read: "(b) Journeyman plumber's Certificate of Qualification or Registration shall be issued to any person who has attained the age of twenty (20) years, has completed a plumbing apprenticeship training course conducted by any (registered) private or governmental agency and has had not less than three (3) full years actual field experience under the immediate supervision of a registered licensed plumber and is able to furnish satisfactory evidence of such fact, or an experience of not less -7- than five (5) full years or its equivalent under the immediate supervision of a registered licensed plumber and is able to furnish satisfactory evidence of such fact, makes application, pays the required i'ee and successfully passes the examination conducted by the Board oi' Examiners. "Master Plumber's Certificate of Qualification or Registration shall be issued to every person who has had issued to him a valid Sourneyman Plumber's Certificate of Qualification or Registration and has participated in said trade for not less than one (1) full year and furnish satisfactory evidence of such fact, makes application, pays the required i'ee and successfully passes the examination conducted by 'the Board of Plumber Examiners." SECTION 16. Amend Section 2.8 to read: "Sec. 2.8 -- Re-Examinations "Any person who fails to pass the regular plumbing examination conducted by the Board of Plumber Examiners shall not request for re- examination. Said person may make application and re-take the next regular plumbing examination, when advertised by i;he Board of Plumber Examiners." SECTION 17. tlmend Section 2.9 to read: "Sec. 2.9 -- Expiration of Certificates of Qualification or Registration "Every Certificate of Qualification or Registration shall remain in force and effect until its expiration date, unless sooner cancelled or revoked. "All Certificate of Qualification or Registration shall expire on the last day of each year." SECTION 18. Amend Section 2.10 to read: "Sec. 2.10 -- Fees for Renewal of Certificates of Qualification or Registration "A l1 Certificate of Qualification or Registration, except certificates which have been cancelled or revoked, may be renewed from year to ,year -8- prior to the expiration date upon request and payment of the required renewal fee as hereinafter provided: "(a) Journeyman Plumber's Certificate or Registration shall be $1.00 and Master Plumber's Certificate of Registration shall. be $2.00 if renewed within thirty (30) days of the expiration date. "(b) If such renewal be requested more than thirty (30) days but less than ninety (90) days after the expiration of such certificate, the renewal fee shall be doubled. "(c) No certificate may be renewed more than ninety (90) days after the expiration date of such certificate." SECTION 19. Amend the terms "building drain," "private sewage disposal system," and "seepage pit" defined in Chapter 1 and add to the list of terms in said Chapter 1 in their respective alphabetical sequence the definition of the terms "Department of Health," "health officer," "individual household aerobic treatment unit," and "private sewage disposal system." A11 said terms to read: "Building drain -- The building drain is that part of the lowest piping of a drainage system which receives the discharge from soil, waste and other drainage pipes inside the walls of the building and conveys it to the building sewer beginning five (5) feet outside the building wall." "Department of Health -- State of Hawaii, Department of Health." "Health Officer -- The Director of Health or his authorized agent." "Individual household aerobic treatment unit -- A water-tight receptacle which receives the discharge of domestic sewage and constructed so as to retain solids, digest organic matter through a period of detension and aeration, and allows the aerated effluent to discharge outside the tank into a sub-surface disposal field or seepage pit." "Private sewage disposal system -- A cesspool, septic tank or an individual household aerobic treatment unit with the effluent discharging into a sub-surface disposal field, into one or more seepage pits or into -9- a combination of sub-surface disposal field and seepage pit, or of such other facilities as may be permitted by the Hea:Lth officer." "Seepage pit -- A seepage pit is a lined excavation in the ground which receives the discharge from private disposal systems so designed as to permit the effluent from the septic tank to seep through its bottom and sides." SECTION 20. Delete paragraph (e) of Section 203. SECTION 21. Add the following Section 211 to Chapter 2 of the Western Plumbing Officials Uniform Plumbing Code to read: "Sec. 211 - Acrylonitrile-Butadiene-Styrene (ABS) Plastic Drain, Waste and Vent Pipe and Fittings and Polyvinyl Chloride (PVC) Ring-rite Pipe and Fittings. "(a) Acrylonitrile-Butadiene-Styrene (ABS) Plastic Drain, Waste and Vent Pipe and Fittings. "This material shall be manufactured in accordance with WPOF1 Product Standard PS 17-65 and installed in accordance with WPOA Installation Standard IS5-65. Each manufacturer of this material shall be required to obtain a separate approval from the Research Committee of the WPOA. "Pipe and fittings shall be marked on opposite sides with at least the following information as mentioned in the above standards: 1. Company name or registered trademark 2. The symbol ABS-DWV 3. Size 4. WPOA Seal of P~pproval 5. llny other markings required or permitted by law 6. Code control identification Its use is limited to residential occupancies not over two stories in height. "(b) Polyvinyl chloride (FVC) Ring-Tite Pipe and Fittings by Johns- Dlanville or approved equal. - 10 - "This 160 p.s.i. pipe has integral bell couplings and rubber ring joints. It shall be used only with Johns-Manville factory made fittings or approved equal, and only male adaptors shall be used when connecting to other materials. Standard cast iron pressure fittings (AWWA Std C100-55) with approved transite adaptors may also be used. The provisions apply to sizes 1-1~2", 2", 3' and 4". "With the 160 p.s.i. PVC Ring-rite Pipe in the 6-inch size, only standard cast iron pressure fittings (1',WWA Std C100-55) with approved transite adaptors shall be used. "Lubricant shall be non-toxic such as the J-M Ring-Tits= Lubricant. Installation of this material shall be in accordance with the manu- facturer's instructions and recommendations. Its use is limited to underground water service outside of the building." SECTION 22. Amend Section 317(e) to read: "(e) Water service pipes or any underground water pipes shall not be run or laid in the same trench with non-metallic building sewer or drainage piping, except as provided in this section. "The water service pipe may be placed in the same trench with such building drain and building sewer, provided both of the following conditions are met: "The bottom of the water service pipe, at all points, shall be at least eighteen (18) inches above the top of the sewer line. "The water service pipe shall be placed on a solid shelf excavated at one side of the common trench." SECTION 23. Delete Section 703(b). SECTION 24. Amend Section 704 to read: "Section 704 - Traps Prohibited. ~~No form of trap which depends for its seal upon the action of movable parts or concealed interior partitions shall be used. Full "S" traps are prohibited except for service sinks. Be 11 traps are prohibited. Crown- vented traps are prohibited. No fixture shall be double trapped. Drum - 11 - traps may be installed only when permitted by the Administrative Authority for special conditions. No drum trap skull be installed without a vent." SECTION 25. Amend the footnote to Section 909 (3) (2) on page 67 to read: "Lead and copper sub-pans or linings shall be insulated from all conducting substances other than their connecting drain by fifteen (15) pound asphalt felt or its equivalent and no lead pan or liner shall be constructed of material weighing less than four (4) pounds per square foot. Copper pans or liners shall be ai; least PSo. 24 B & S gauge (.02). Joints in lead and copper pans or liner shall be soldered, burned or silver brazed respectively." SECTION 26. Amend Section 910 to read: "Each building shall be provided with sanitary facilities as prescribed by the Department of Health, State of Hawaii." SECTION 27. Amend Section 409(1) to read: "(1) When subsoil drainage systems are installed, they shall be discharged into an approved sump or receiving tank and shall be discharged in a manner satisfactory to the Administrative Authority of the Department of Health." SECTION 28. Amend Section 1008(b) (1) to read: "(1) The bottom of the water service pipe, at all points, shall be at least eighteen (18) inches above the top of the sewer line." SECTION 29. Amend Section 1103(a) to read: "(a) The building sewer, beginning five (5) feet from any building or structure, shall be of such materials as may be approved by the Administrative Authority under the approval procedures set i'orth in Chapter 2 of this Code. SECTION 30. Amend Section 1106(c) to read: "(c) No building sewer or other drainage piping or part thereof, which is constructed of materials other than those approved for use under or within a building, shall be installed under or within five (5) - 12 - feet of any building or structure or part thereof, nor less than one (1) foot below the surface of the ground. The provisions of this subsection include structures such as porches and steps, whether covered or un- covered, breezeways, roofed pone-cocheres, car-ports, covered walks, covered driveways and similar structures or appurtenances." SECTION 31. Amend Section 1107(a) to read: "(a) Cleanouts shall be placed in every building sewer at the junction with the soil pipe at the building and. at intervals not to exceed fifty (50} feet in straight runs. The cleanout and fitting at the junction of the building drain and the sewer shall be of the same material as approved For the building drain." SECTION 32. Amend Section 1108-1 to read: "1. The bottom oi' the water piping at all points shall be at least eighteen (18) inches above the top of the sewer piping." SECTION 33. Amend Section 1110(a) to read: "(a) Except as provided in subsection (b) of this section, no building sewer or private sewage disposal system or parts thereof, shall be located in any lot other than the lot which is the site of the building or structure served by such sewer or private sewage disposal system; nor shall any building sewer or private sewage disposal system or part thereof be located at any point having less than the minimum distances as required by the Department of Health regulations." SECTION 34. Delete Sections 1111 to 1118, inclusive, of the Western Plumbing Officials Uniform Plumbing Code. SECTION 35. Amend Sections 1119(b), (c) and (d) to read: "(b) Every cesspool, septic tank, aerobic treatment tank and seepage pit which has been abandoned or has been discontinued otherwise from further use or to which no waste or soil pipe from a plumbing fixture is connected, shall have the sewage removed therefrom and be completely filled with earth, sand, gravel, concrete or other approved material. - 13 - "(c) The top cover or arch over the cesspool, septic tank, aerobic treatment tank or seepage pit shall be removed before filling and the filling shall not extend above the top of the vertical portions of the sidewalls or above the level of any outlet pipe until inspection has been called and the cesspool, septic tank, aerobic treatment tank or seepage pit has been inspected. After such inspection, the cesspool, septic tank, aerobic treatment tank or seepage pit shall be filled to the level of the top of the ground. '(d) No person owning or controlling any cesspool, septic tank, aeroblc treatment tank or seepage pit on the premises of such person or in that portion of any public street, alley or other public property abutting such premises, shall fail, refuse or neglect to comply with the provisions of this seciion or upon receipt of notice so to comply from the Department having ,jurisdiction.' SECTION 36. Delete Table 11-1, appearing after Section 1119, in its entirety. SECTION 37. Amend Section 1203(a) to read: "(a) It shall be unlawful for any person except a licensed plumber or a gas utility to install, alter or repair or cause to be installed or repaired any gas house piping. Before commencing said work, a permit shall be obtained from the Administrative Authority. No permit shall be required from a public utility to disconnect defective gas piping or equipment when authorized by Section 1209." SECTION 38. Delete Section 1207 in its entirety. SECTION 39. Amend Section 1211(f) to read: "(f) Gas meters installed indoor shall not be installed in bed- rooms, closets, bathrooms, under combustible stairways or in unventilated places nor closer than three (3) feet to sources of ignition, including furnaces and water heaters." SECTION 40. Amend Section 1212 to read: "Sec. 1212 -- Materials for Gas Piping - 14 - "(a) Pipe. All pipe used for the alterations, extension, installation or repair of any gas piping shall be standard weight wrought iron, steel, threaded copper or brass. "(b) Tubing. Seamless copper, brass or steel tubing may be used. Copper tubing shall be of the standar3 type K or L, or equivalent, having a minimum wall thickness of 0.032 inch. "(c) Pipe Joints and Fittings. Pipe joints may be screwed, flanged, or welded and non-ferrous pipe may be brazed or soldered, with a material having a melting point in excess of 1000oF. Tubing joints shall either be made with approved flared fittings or be soldered or brazed with a material having a melting point in excess of 1000°F. Compression type tubing fittings shall not be used for this purpose. "Fittings (except stopcocks or. valves) shall be malleable iron for steel or wrought iron pipe, and shall be copper or brass when used with copper or brass pipe or tubing. "(d) Valves. rill valves and appurtenances used in connection with the above piping shall be of the type designed and approved for use with the fuel gas. "(e) Joint Compounds. Joint compounds (pipe dope) shall be applied sparingly and only to the male tkireads of the pipe joints. Such compounds shall be insoluble in the presence of the fuel gas." SECTION 41. Amend Section 1213(d) to read: "(d) Ferrous gas piping installed underground in exterior locations shall be protected from corrosion 'oy approved coatings or wrapping materials when the soil resistivity is less th<~n 4,500 ohm-cm and all such horizontal piping shall have at least eight (E3) inches of earth cover or equivalent protection. Risers shall be wrapped to a point at least four (4) inches above grade." SECTION 42. Amend Section 1213 by adding a new subsection numbered (n) to read: "(n) Gas appliances shall be connected to the gas piping with - 15 - rigid pipe, listed metal appliance connectors, approved flexible metal connectors or approved semi-rigid tubing in lengths up to six (6) feet (for heaters, see Sec. 1312 - Gas Connections). When an appliance connector or tubing is used, it shall connect 'to an outlet in the same room as the appliance. The connector or tubing shall not be installed inside walls or partitions unless protected against physical damage." SECTION 43. Amend Section 1214(b) to read; "(b) Where liquefied petroleum gas facilities serve more than one (1) customer through separate piping systems, each system shall be identified in a manner satisfactory to the Administrative Authority and the supplier, and all gas meter locations shall be approved by the supplier." SECTION 44. Amend Section 1214(1) to read: "(i) Requirements for discharge from relief valves shall conform to state fire prevention regulations." SECTION 45. Amend Section 1217(a) to read: "(a) The following regulations as set forth in this section and Section 1218 - 'Required Gas Piping Size' shall be the standard for the installation of gas piping. All regulations acid tables are based on the use of propane gas having a specific gravity of one and fifty-two hundredths (1.52), supplied at approximately eleven (11) inches water column pressure at the outlet of the meters." SECTION 46. Amend Section 1217(e) to read: "(e) The size of the supply pipe outlet for any gas appliance shall be no less than the size specified in Table 12-2, and in no case smaller than one-half (1~2) inch. The minimum size of any piping outlet for a gas range, a recessed top burner section, or a house trailer shall be one-half (1~2) inch for LPG." SECTION 47. Amend Table 12-1, appearing after Section ].21'T(a), to read: - lE - "Table 12 - 1 Minimum Demand of typical. gas appliances in cubic feet per hour (CFH) (Based on Propane gas 2500 B.T.U, per cubic foot) Appliance Demand Domestic Gas Range 3p Domestic Recessed top burner section 20 Domestic Recessed oven section 10 Storage water heater - up to 30 gal. tank 14 Storage water heater - 4C and 50 gal. tank 18 Domestic Clothes Dryer 12 Fireplace log lighter (residential) 12 Barbecue (residential) 20 Gas Refrigerator 2 Bunsen burner 2 House Trailers (each) Gas Engines (per horsepower) 4 Steam boilers (per horsepower) 20 Luau torch 7 * Branches and mains serving house trailer sites using the following values beginning with the most remote outlet; on each branch or main: For the first outlet on any branch or main 50 CFH For the second outlet on any branch or main 40 CFH For the third outlet on any branch or main 30 CFH !'after the third outlet, subsequent main lines loading may be computed using a value of twenty (20) cubic feet per outlet. An approved gas valve shall be installed at each outlet." SECTION 48. Amend the "NOTE" after subsection (d) in Section 1218 to read: "NOTE: See Appendix F for specific requirements. Gas piping systems conveying propane gas at pressure of three (3) or five (5) p.s.i.g. may be sized in accordance with Tables contained in Appendix F." SECTION 49. Amend Table 12-2, appearing after Section 1218, to read: "Table 12-2 GAS PIPE SIZING TABLE PIPE SIZE LENGTH IN FEET lo' 20' 30' 40' So' 3/8* 15 l0 8 7 1/2 50 35 2g 25 22 3/4 140 loo So ~0 61 1 285 200 165 140 125 1 1/4 500 350 290 250 220 1 1/2 Igo 560 450 390 350 * Semirigid Tubing - 1~- 60' 70' 80' 90' 1/2 20 19 18 17 3/4 58 52 49 46 1 115 105 100 95 1 1/4 200 185 170 160 1 1/2 32C 290 275 260 250' 300' 350' 400' 3/4 28 25 23 22 1 56 52 47 45 1 1/4 100 90 85 80 1 1/2 155 140 130 120° SECTION 50. Amend Section 1301 to read: "Sec. 1301 -- General "The regulations of this chapter shall govern the construction, location and installation of gas-fired and other water heaters heating potable water, together with all flues, vents and vent connectors for the same. All design, construction and workmanship shall be in conformity with accepted engineering practices and shall be of character as to secure the results sought to be obtained. by this Code. No water heater shall be hereinafter installed which does not ccmply in all respects with the type and model of each size thereof approved by the Administrative Authority. However, nothing in this Code shall be interpreted so as to conflict with the Building Code of the County of Hawaii." SECTION 51. Amend Section 1305(c) to read: "(c) Gas storage-type water heaters and hot water boilers shall be equipped, in addition to the primary temperature control, an approved automatic gas shut-off system, a temperature relief valve or a combination temperature and pressure relief valve. "An automatic gas shut-off system shall be either factory installed or shipped with the appliance accompanied by complete instructions for their installation. - 18 ... "The temperature relief valve or the combination temperature and pressure relief valve used shall not have an inlet connection less than 3~4", shall have a capacity to prevent water in the heater from exceeding 210 degrees Fahrenheit maximum temperature and shall be installed within three (3) inches of the hottest part of the heater tank served." SECTION 52. Amend Section 1307(c) 3 to read: "3. For gas-burning water heaters, all openings or ducts shall have a total unobstructed area not less than one square inch for each two-thousand (2000) B.T. U. 's of heat to all heaters in such compartment." SECTION 53. Amend Section 1307(e) to read: "(e) Alternate Methods of Supply Combustion P.ir "In lieu of requirements of Section 1307(c), combustion air supply may be designed in accordance with recognized engineering principles when first approved by the Administrative Authority." SECTION 54. Delete Table 13-1, appearing after Section 'L307(e), in its entirety. SECTION 55. Amend Section 1310(a) to read: "(a) tdater heater generating a glow, spark or flame capable of igniting flammable vapors may be installed in a residential garage provided the pilots and burners, or heating elements and switches, are at least eighteen (18) inches above the floor." SECTION 56. Amend Section 1312(a) (1) to read: "(1) Gas heater burning not more than 100,000 B.T.iJ.'s may be connected with approved type semi-rigid or other approved all metal, seamless tubing connectors of brass, steel or copper. Copper tubing shall be of the standard grade K or I. or having a minimum thickness of 0.032 inch." SECTION 57. Amend Section 1312(c) to read: "(c) Connector an3 fittings conforming to the approved standards may be considered as meeting the foregoing requirements." - 19 - SECTION 58. Amend Section 13 i3 to read: "Sec. 1313 - Pressure Relief Valves "A11 water heating appliances which are installed in a closed system of water piping or any water heater connected to a separate storage tank and having valves between said heater and tank shall be provided with a water pressure relief valve or a combination water pressure and temperature relief valve set at a pressure of not more than one hundred and fifty (150) pounds per square inch gauge pressure nor the maximum design operating pressure of the system." SECTION 59. Amend Section 1314 by adding a rtew subsection numbered (e) to read: "(e) Listed water heaters located outside of, in enclosures outside of, or under building structures aha7.1 be considered properly vented when installed with their listing requirements and manufacturer's instructions. Vent requirements as set forth in Chapter 13 shall not apply except that: "1. Vent terminals shall not be located less than twelve (12) inches from any building opening or be less than thirty (30) inches from any combustible overhead building structure or enclosure roof. This distance may be reduced to six (6) inches if the combustible material is protected with an asbestos board 16" x 16" x 1~4", centered over the heater flue apace out one-half (1~2) inch. (Spacers shall be of non-combustible material.) "2. Gas heater installations under building structures must also comply with the following: All air for combustion is derived directly from the outside air and all vent gases are discharged to the outside atmosphere; two (2) approximately equal permanent fresh :sir openings for combustion shall be provided, one within six (6) inches of the ceiling; the aggregate of the fresh air openings shall not be less than eight hundred (800) square inches nor less than one (1) square inch for fifty (50) B.T.U. of heat input for all gas water heaters in such under house locations." -20 - SECTION 60. Delete Appendix C, appearing on pages 142 and 143, in its entirety. SECTION 61. Delete Appendix D, appearing on pages 144 to 148, inclusive, in its entirety. SECTION 62. Amend Appendix F, appearing on pages 155 to 157, inclusive, to read; "APPENDIX F Medium Pressure Gas Piping Systems F1 - Definitlons Medium Pressure - pressure over fourteen (14) inches of water column but not to exceed five (5) p.s.i.g. F2 - Approval of both the Administrative Authority and the Gas Utility shall be obtained before any medium pressure gas piping system is installed. F3 - Except as set forth herein, the requirements of Chapter 12 shall apply to medium pressure gas piping systems. F4 - Approved regulators shall be installed on medium pressure gas piping systems, in approved locations either outside the building or inside when vented to the out„ide or when equipped with a vent limiting device which shall limit the escape of gas to not more than 0.5 standard cubic feet per hour, iu non-hazardous well ventilated interior locations and shall be readily accessible for servicing. F5 - An approved gas valve shal"i be installed immediately preceding each regulator. All regulators that may be subjected to mechanical damage shall be substantially protected to Che satisfaction of the Administrative Authority. F6 - Tables F1 and F2 may be used to size propane gas piping systems carrying three (3) or five (5) p.s.i.g. gas. The procedure to determine the size of each section of the system is similar to that contained in Section 1218 of this Code using the pipe length from the meter to the most remote regulator on the medium pressure system and sizing the downstream low pressure piping from Table 12-2. F7 - Buried medium pressure gas piping shall be protected from corrosion as required by Chapter 12 and shall have a minimum earth cover of twelve (12) inches. Such piping shall be covered with at least six (6) inches of hand placed selected backfill devoid of rocks, building materials or other matter that may damage the pipe or wrapping. - 21 - TABLE F - 1 FOR SIZING GAS PIPING SYSTENiS C!1RRYING GAS OF 1.52 SPECIFIC GRAVITY Capacity of pipes of different diameters and length in cubic feet per hour for gas pressures 2.0 psi with a drop oi° 1.5 psi. PIPE SIZE _ __ :LENGTH OF' PIPE FEET lo~ 20 ~ 30 ~ 40 50 50 70 3/8~ 180 125 -loo 85 80 70 55 1/2* 475 340 260 220 195 175 155 3/4 2600 1850 1500 1250 1100 1000 900 1" 4400 3000 2400 2000 1800 1700 1500 TABLE F - 2 Capacity of pipes of different diameters and. length in cubic feet per hour for gas pressures 5.0 psi with a drop of 1.5 psi. PIPE SIZE LENGTH OF PIPE FEET SO 20 30 40 50 60 70 3/8* 1500 900 700 600 500 450 400 1/2* 2300 1600 1300 1100 1000 900 850 3/4 3950 2600 2100 1800 1600 1450 1350 I" 4000 3200 2750 2850 2700 2500 2300 *' Tubing O.D." SECTION 63. Add Appendix G after Appendix F to read: "APPENDI:{ G Under Concrete of In Concrete Slab Gas Piping G1 - Gas piping may be embedded in concrete floor slabs constructed with Portland cement. Piping shall be surrounded with a minimum of 1 1/2 inches of concrete and shall not be in physical contact with other metallic structures such as reinforcing rods or electrical neutral conductors. At the point of entry into concrete slab piping shall be suitably protected from corrosion by a non-metallic sleeve. Piping shall not be embedded in concrete slabs containing calcium chloride or similar corrosive qui.ckset additives. G2 - Gas piping may be installed under a concrete floor slab provided: G2.1 - All ferrous piping shall have approved protective coatings as specified in Section 1213(e). _22 G2.2 - All piping shall be installed at least six (6) inches below the bottom of the concrete slab. Material used for backfill around pipe shall be free of rocks larger than 5~8 inch in diameter, building mar,erials, hot ashes and trash. G2.3 - Protective coatings or. ferrous pipe shall extend at least one (1) inch above the floor grade on outlets installed through the concrete floor slabs. G2.4 - When ferrous piping is used an approved dielectric fitting shall be installed on the hot and cold water lines at the water heater. G2.5 - Ferrous gas piping systems shall be at least one (1) inch from any other metallic structure, such as concrete reinforcing, water lines, drain lines, or eleceric:al grounding systems. G2.6 - An approved five (5) pound magnesium or zinc sacrifical anode shall be connected adjacent to ferrous gas piping outside of the slab and shall be buried in rock free backfill deeper than the piping protected. Anode lead wires shall be attached to the piping by soldering, conventional ground water clamp connections or Thermit welding, limited to a 15 milligram cartridge. Brazing by any other method is prohibited." SECTION 64. Offenses under former ordinances saved. Nothing contained in any provision of this ordinance shall apply to an act done or omitted, or to an offense committed at any time before the enactment of this ordinance. Such act or omission shall be governed by, and any such offense shall be punished according to the provisions of the ordinances existing when such act, omission or offense, occurred in the same manner as if this ordinance had not been enacted. SECTION 65. Repeal of prior ordinance, preservation of rights and liabilities, construction of revised ordinance. a. Repeal of prior ordinance; what not repealed. All ordinances, sections and parts of sections of Ordinances of the County of Hawaii, in conflict herewith, be and the same i.s hereby repealed. b. Preservation of rights and liabilities. Said repeal shall not affect any act done, ratified or confirmed, or any right accruing or accrued or established, or any action, suit or proceeding had or commenced in any civil cause, prior to said repeal, but al'L rights and liabilities under any ordinance embraced in the said ordinance or so repealed shall continue, and may be enforced in the same manner and with the same - 2 3 - effect as if said repeal had not been made. c. Construction of Revised Ordinances. Provisions in said ordinance shall be construed as continuations or amendments of applicable or corresponding provisions of previously existing laws and. not as new enactments. In case of a conflict between said and other ordinances, or in case of latent and patent ambiguity or obvious clerlcal error in said ordinance, reference may be made to the previously existing ordinances for the purpose of applying the rules of construction relating to repeal by implication or for the purpose of resolving the ambiguity or correcting the error. -24-