Loading...
HomeMy WebLinkAboutORD 1974-080BILL NO. 69 (AMENDED) COUNTY OF HAWAII - STATE OF HAWAII ORDINANCE NO. AN ORDINANCE AMENDING ORDINANCE NO. 502 (PLUMBING AND GAS CODE), ADOPTEll ON JULY 26, 1972, SPECIFYING PROVISIONS TO BE MADE IN THE CONSTRUCTION OF BUILDINGS OR STRUCTURES IN AREAS WITH SF DESIGNATION ON THE ZONE MAPS IDENTIFIED AS BEING SUBJECT TO INUNDATION BY RAIN WATER OR SEA WATER, OR BOTH, AND REPEALING ALL SECTIONS AND PARTS OF SECTIONS OF ORDINANCES OF THE COUNTY OF HAWAII IN CONFLICT THEREWITH. BE IT ORDAINED BY THE COUNCIL OF THE COUNTY OF HAWAII: SECTION :L. Amending Section 321 of the Plumbing Code. Section 321 is amended by adding the following: "A11 plumbing within an area identified as being subject 'to inundation by rain water or sea water, or both, shall men=_t all provisions of the plumbing code. In addition, the following provisions shall be followed. Where there is a conflict between these provisions and other se~~tions of the plumbing code, these provisions shall prevail. A. Water Supply 1. Back flow prevention. An approved reduced pressure back flow prevention device shall be installed in each of the following locations: (a) At the point that the water supply line crosses into the limit of the flood area. (b) At each supply line to any irrigation or lawn sprinkling system. (c) Wherever other sections of this code requires a vacuum breaker. B. Drainage 1. All drainage piping serving fixtures below the second floor or the maximum expected flood level shall discharge into an approved water-tight sump or :receiving tank, so located as to receive the sewage or wastes by gravity. From such sump or reci=_iving tank the sewage or other liquid wastes shall be lifted and discharged into the building drain or building sewer by approved ejectors, pumps or other equally efficient approved mechanical device. 2. The minimum size of any pump or any discharge pipe from a sump having a water closet connected thereto shall be not less than two (2) inches. 3. The discharge line from such ejector, pump or other mechanical device shall be provided with an acasssible back water valve and gate valve and if the gravity drainage line to which such discharge line connects is horizontal, the method of connection shall be from the top through a "wye" branch fitting. 4. Building drains or building sewers receiving discharge from any pump or ejector shall be adequately sized to prevent overloading. Two (2) fixture units shall be allowed for each gallon per minute of continuous flow. 5. Back-water valves, gate valves, motors, compressors, air tanks or other mechanical devices required by this section, shall be located where they -2- will be readily and easily accessible for inspection and repair at all times and unless continuously exposed, shall be enclosed in a water tight masonry pit fitted with an adequately sized removable cover. 6. The drainage and venting systems in connection witki fixtures, sumps, receiving tanks and mechanical waste lifting devices, shall be installed under the same requirements as provided for in this code for gravity systems. 7. Sumps and receiving tanks shall be watertight and shall be constructed of concrete, metal or other approved materials. If constructed of poured concrete, the walls and bottom shall be adequately reinforced and designed to recognized acceptable standards. Metal sumps or tanks shall be of such thickness as to serve their intended purpose and shall be treated internally and externally to resist corrosion. 8. All such sumps and receiving tanks shall be automatically discharged and when in any public use' occupancy shall be provided with dual pumps or ejectors arranged to function independently in case of overload or mechanical failure. The lowest inlet shall have a minimum clearance of twelve (12) inches from the high water or 'starting' level of the sump. 9. Sumps and receiving tanks shall be provided with substantial covers having a bolt and gasket type manhole or equivalent opening to permit access for inspection, repairs and cleaning. The top shall be provided with a vent pipe which shall extend -3- sep+~rately through the roof. Such vent shall be large enough to maintain atmospheric pressure within the sump under all normal operating conditions and in no case shall be less in size than that required by 'Fable 4-3 for the number of fixtures discharging into the sump, nor less than one and one-half (1-1/2) inc]Zes in diameter. No vent from a sewage ejector shall combine with other vents. Vents shall terminate above the roof." SECTION 2. The Chief Engineer shall have the authority to consider exceptions to the provisions of Section 1 of this ordinance and may grant variances from the provisions thereof if local topographic conditions clearly indicate that the possibility of flooding is not present. SECTION 3. This ordinance shall take effect on December 31, 1974. INTRODUCED BY: COUNCILMAN, COUNTY F HAWAII Hilo, Hawaii Date of Introduction: August 21, 1974 Date of Adoption: December 4, 1974 Effective Date: December 31, 1974 - 4- Hilo, Hawaii Date: liugust 21, 1974 FIRST READING AYES NOES A/E Car enter x De Luz x Farias x Fujii x Hisaoka x Kawahara x ~p~xxxx xxxxxxx xxxxxx xxxxxx Yadao Ag Chr. Yamada x 7 1 Publication Date: _ AUCJllSt 27, 1974 Kona, Hawaii Dare: December 4 7.974 SECOND & FINAI READING AYES NOES A/E Carpenter x De Luz g SFmkTSxxxxxxx xxxxxx xxxxxxx xXxxx Fujii x Hisaoka x Kawahara x even ~€iYa~rfs~ x Yadao A8 Chr. Yamada x 7 1 Publication Date: ~'~~ 1 ~ 1974 We do hereby certify that Tlhe foregoing BILL was adopted by The County Council and published as indicated above. ~.:int ~ ~^ r r trti ~~.~-~~ r '°, .~o __ _ ~, Dale _- -- Y~ Approved/Disap{xeved this ~ ~. day o4 _ ~ ~ (C~.-~„ ~.. _ 19~_. 1 7T - ~~ Council Chairman County Clerk ~~ ~/~r i C%'d ~ J ~i,.~ Mayor, County of Hawaii Bill No. 69 _ Reference- C-937/PWC-38 M.B. No. - __ _ _ _~,, Ord. No. ~' Bill No. 69 - 1974 AN ORDINANCE AMENDING ORDINANCE N0. 502 (PLUMBING AND GAS CODE), ADOPTED ON JULY 26, 1972, SPECIFYING PROVISIONS TO BE MADE IN THE CONSTRUCTION OF BUILDINGS OR STRUCTURES IN AREAS WITH SF DESIGNATION ON THE ZONE MAPS IDENTIFIED AS BEING SUBJECT TO INUNDATION BY RAIN WATER OR SEA WATER, OR BOTH, AND REPEALING ALL SECTIONS AND PARTS OF SECTIONS OF ORDINANCES OF THE COUNTY OF HAWAII IN CONFLICT THEREWITH. This Bill amends Ordinance No. 502 (Plumbing and Gas Code) adopted on July 26, 1972, specifying provisions to be made in the construction of buildings or structures in areas with SF designation on the Zone Maps identified as being subject to inundation by rain water or sea water, or both, and repealing all sections and parts of sections of ordinances of the County of Hawaii in conflict therewith. Date Introduced: .August 21, 1974 Copies of the foregoing Bill, in full, are on £ile in the Office of the County Clerk for use and examination by the public. I hereby certify that the foregoing Bill passed first reading at the meeting of the County Council on August 21, 1974, by the following aye and no vote: AYES: Councilmen Carpenter, De Luz, Farias, Fujii, Hisaoka, Kawahara and Chairman Yamada - 7. NOES: None. ABSENT AND EXCUSED: Councilwoman Yadao - 1. ~../..~d~:.. O\ -~'CJ COUNTY CLERK ORDINANCE NO. 80 (Bill No. 69-1974) AN ORDINANCE AMENDING ORDINANCE NO. 502 (PLUMBING AND GAS CODE), ADOPTED ON JULY 26, 1972, SPECIFYING PROVISIONS TO BE MADE IN THE CONSTRUCTION OF BUILDINGS OR STRUCTURES IN AREAS WITH SF DESIQNATION ON THE ZONE MAPS IDENTIFIED AS BEING SUBJECT TO INUNDATION BY RAIN WATER OR SEA WATER, OR BOTH, AND REPEALING ALL SECTIONS AND PARTS OF SECTIONS OF ORDINANCES OF THE COUNTY OF HAWAII IN CONFLICT THEREWITH. Date Approved: December 4, 1974 Date Effective: December 31, 1974 Copies of the foregoing Ordinance, in full, are on file in the Office of the County Clerk for use and examination by the public. I hereby certify that the foregoing Ordinance passed second and final reading at the meeting of the County Council on December 4, 1974, by the following aye and no vote: AYES: Councilmen Carpenter, De Luz, Fujii, Hisaoka, Kawahara, Levin and Chairman Yamada - 7. NOES: None. ABSENT AND EXCUSED: Councilwoman Yadao - 1. v~ COUNTY CLERK COUNTY OF HAWAII ~~~~. ~ n.nerclreKti nlu m.eawepro or p~mMl~iia N. K1r°CM M SCgi11cK m _ ~, EXEYLFy: -taim- L SLLKY• LBBRK `M'e!-H~w 1~TIwMFINCarld: S .u, t/~d Y~1~% k F \l.:? `'' ~ R Ted T. Suzuki '" t ". COUNTY CLERK. ^ r Robert Shioji • HP DEPUTY COUNTY CLERK OFFICE OF THE CC7UNTY CLERK COUNTY OF HAWAII H ILO, HAWAII 9672C Mayor Herbert T. Matayoshi County of Hawaii Hilo, Hawaii I hereby transmit Ordinance Sill No. 69 passed by the County Council on second and final reading. COUNTY CLERK Encl. f Dated: separately through the roof. Such vent shall be large enough to maintain atmospheric pressure within the sump under all normal operating conditions and in no case shall be less in size than that required by Table 4-3 for the number of fixtures discharging into the sump, nor less than one and one-half (1-1/2) inches in diameter. No vent from a sewage ejector shall combine with other vents. Vents shall terminate above the roof." SECTION 2. The Chief Engineer shall have the authority to consider exceptions to the provisions of Section 1 of this ordinance and may grant variances from the provisions thereof if local topographic conditions clearly indicate that the possibility of flooding is not present. SECTION 3. This ordinance shall take effect upon its approval. INTRODUCED BY: COUNCILMAN, COUNTY HAWAII Date of Introduction Date of Adoption: August 21, 1974 -4-