Loading...
HomeMy WebLinkAboutBIL 250 Draft 01 2008-2010 OFFICE OF THE COUNTY CLERK County of Hawai`i Hilo , Hawai`i CL ( ` ROLL CALL VOTE Introduced By: Pete Hoffmann AYES NOES ABS EX Date Introduced: May 5, 2010 Enriques X First Reading: May 5, 2010 Ford X Published: 1/7`A Greenwell X Hoffmann X REMARKS: Ikeda X Naeole-Beason X Onishi X Yagong X Yoshimoto X 6 1 2 0 Second Reading: May 19, 2010 ROLL CALL VOTE To Mayor: N/A AYES NOES ABS EX Returned: N/A Enriques Effective: N/A Ford Published: N/A Greenwell Hoffmann REMARKS: Ikeda 5/19/10 — Withdrawn by Mr. Hoffmann Naeole-Beason Onishi Yagong Yoshimoto I DO HEREBY CERTIFY that the foregoing BILL was adopted by the County Council published as indicated above. APPROVED AS TO FORM AND LEGALITY: COUNCIL CHAIRMAN DEPUTY CORPORATION COUNSEL COUNTY OF HAWAII COUNTY CLERK Date 250 Bill No.: C-809/WAIVED-PWIRC Approved/Disapproved this day Reference: Ord No.: of , 20 MAYOR, COUNTY OF HA WAI`I COUNTY OF HAWAII ORDINANCE NO. STATE OF HAWAII BE IT ORDAINED BY THE COUNCIL OF THE COUNTY OF HAWAII: [ "(2) Amending Section 101.5.2. Section 101.5.2 is amended to r ad: [ "(1) Amending Scction 401.1. Section 101.1 is amcndcd to r ad: BILL NO. zso AN ORDINANCE AMENDING CHAPTER 5, ARTICLE 2 OF THE HAWAII COUNTY CODE 1983 (2005 EDITION, AS AMENDED), RELATING TO THE INTERNATIONAL ENERGY CONSERVATION CODE. SECTION 1. Chapter 5, article 2, section 5- 2.1.1, Hawai`i County Code 1983 (2005 Edition, as amended), is amended by repealing item (2): separated from the remainder of the building by building thermal envelope less than 3.1 Btu/h•ft 4-1-077- or 1.0 watbfr (10.7 W/m be exempt from the building thermal cnvclope provisions of this coda "] SECTION 2. Chapter 5, article 2, section 5- 2.1.1, Hawai`i County Code 1983 (2005 Edition, as amended), is amended by repealing item (4): SECTION 3. Chapter 5, article 2, Section 5- 2.1.1, Hawai`i County Code 1983 (2005 Edition, as amended), is by amending item (5) to read as follows: "(5) Amending Table 402.1.1. [Footnote h is added to] Table 402.1.1 is amended to read: Climate Zone Fenestration U- Factor Skylight U- Factor Glazed Fenestration SHGC Ceiling R- Value Wood Frame Wall R -Value Mass Wall R -Value Floor R -Value Basement` Wall R -Value Slab R -Value & Depth Crawl Space Wall R -Value 1 120 0.75 0.40 30 " 13 3 I4 -310 0 0 0 2 0.75 0 75 0.40 30 13 4 13 0 0 0 3 0.65 0 65 0.40 ` 30 13 5 19 0 0 5 / 13 4 except Marine 0.40 0.60 NR 38 13 5 19 10/13 10,2ft 10/13 5and Marine 4 0.35 0.60 NR 38 19 or 13 +5g 13 30 10/13 10,2ft 10/13 6 0.35 0.60 NR 49 19 or 13 +5 15 30 10/13 10.4ft 10/13 7 and 8 0.35 0.60 NR 49 21 19 30 10/13 10,4ft 10/13 "TABLE 402.1.1 INSULATION AND FENESTRATION REQUIREMENTS BY COMPONENT a For SI: 1 foot = 304.8 mm. NR = No requirement. a. R- values are minimums. U- factors and SHGC are maximums. R -19 shall be permitted to be compressed into a 2 x 6 cavity. b. The fenestration U- factor column excludes skylights. The SHGC column applies to all glazed fenestration. c. The first R -value applies to continuous insulation, the second to framing cavity insulation; either insulation meets the requirement. d. R -5 shall be added to the required slab edge R- values for heated slabs. e. There are no SHGC requirements in the Marine zone. f. Or insulation sufficient to fill the framing cavity, R -19 minimum. g. "13 +5" means R -13 cavity insulation plus R -5 insulated sheathing. If structural sheathing covers 25 percent or less of the exterior, insulating sheathing is not required where structural sheathing is used. If structural sheathing covers more than 25 percent of exterior, structural sheathing shall be supplemented with insulated sheathing of at least R- 2. h. The ceiling insulation alternative in Section 402.1.1.1 can be used as an equivalent alternative for R -30." SECTION 4. Chapter 5, article 2, section 5- 2.1.1, Hawaii County Code 1983 (2005 Edition, as amended), is amended by amending paragraph (6) of item (6) to read as follows: "6. For compliance with Subsection 1.4, a cool roof shall have an infrared [cmittance] emissivity of no [mere] less than 0.75 when tested in accordance with ASTM E -408 and a high solar reflectance. Altematively, the corresponding Solar Radiance Index (SRI) for a cool roof can be used. The manufacturer's test results shall be acceptable for compliance. A cool roof has both a light color (high solar reflectance) and a high [e mittance] emissivity (can reject heat back to the environment). White painted surfaces and other smooth white coatings typically 2 meet these requirements. Surfaces that do not meet the requirements include unpainted metal and metalized roof coatings (silver appearance)." SECTION 5. Chapter 5, article 2, section 5- 2.1.1, Hawai`i County Code 1983 (2005 Edition, as amended), is amended by amending item (12) to read as follows: "(12) Amending Section 403. Section 403 is amended by adding Section 403.7 to read: "403.7 Residential pools. Residential pools shall be provided with energy conserving measures in accordance with Sections 403.7.1 through 403.7.3. 403.7.1 Pool heaters. All pool heaters shall be equipped with a readily accessible on -off switch to allow shutting off the heater without adjusting the thermostat setting. Pool heaters fired by liquid propane or natural gas shall not have continuously burning pilot lights. 403.7.2 Time switches. Time switches that can automatically turn off and on heaters and pumps according to a preset schedule shall be installed on swimming pool heaters and pumps. Exceptions: 1. Where public health standards require 24 -hour pump operation; 2. Where pumps are required to operate solar- and waste - heat - recovery pool heating systems. 403.7.3 Pool covers. Heated pools shall be equipped with a vapor retardant pool cover on or at the water surface. Pools heated to more than 90 ° F (32 ° C) shall have a pool cover with a minimum insulation value of R -12. Exception: Pools deriving over 60 percent of the energy for heating from site - recovered energy or solar energy source." SECTION 6. Material to be repealed is bracketed and stricken through. Material to be added is underscored. In printing this ordinance, the Revisor need not print the brackets, bracketed and stricken material, and underscoring. The Revisor shall renumber items under chapter 5, article 2, section 5 -2.1.1 in accordance with those items that have been repealed by this ordinance. SECTION 7. Nothing in this ordinance or in the Energy Conservation Code hereby adopted shall be construed to affect any suit or proceeding impending in any court, or any rights acquired, or liability incurred, or any cause or causes of action acquired or existing, under any act or ordinance; nor shall any just or legal right or remedy of any character be lost, impaired or affected by this ordinance. 3 SECTION 8. If any provision of this ordinance or the application thereof to any person or circumstance, is held invalid, such invalidity shall not affect other provisions or applications of the ordinance that can be given effect without the invalid provision or application, and to this end, the provisions of this ordinance are declared to be severable. SECTION 9. This ordinance shall take effect upon approval. Cfff, COUN MBER, LINTY OF HA AI`I , Hawai`i Date of Introduction: Date of 1st Reading: Date of 2nd Reading: Effective Date: C�cftRb'$C+Es Comm. .......8O9 4