TESTIMONY OF MICHAEL KALEIKINI,
PLANT MANAGER, PUNA GEOTHERMAL VENTURE
(6-6-12 Council Hearing re Bill 256)
As you know, Puna Geothermal Venture (PGV) has submitted a request to present
detailed information regarding its operations that have been safeguarding the community since
the project came online. We have also asked that the Hawaii Department of Health be invited to
discuss the safety of PGV's operations and the ambient levels of naturally occurring gases. We
don't think we can convey all of the points that need to be addressed in the confines of this three-
minute window, today.
If granted the opportunity to present, we will provide experts to address and answer any
questions the committee and the public might have of PGV. Our goal is that PGV be an asset,
not a liability, in assessing what is occurring environmentally in our community using what
we've learned from our years of extensive monitoring.
Concluding that residences within a one-mile radius are inhabitable harms the public
perception about the safety of geothermal energy production. In my opinion, this approach fails
to address the potential issue of health effects caused by natural emissions from the rift in the
Puna District which are thought to be greater than any potential emissions from PGV. This is
why we are encouraging testimony from the Hawaii Department of Health, as well.
A report prepared by the US Dept. Of Health and Human Services' Senior
Toxicologist analyzed PGV's operations and air monitors at the plant, at the plant's perimeter,
and at monitoring stations located at Lanipuna Gardens and Leilani Estates, based on a 16-month
period between January 1996 and April 1997. A copy of that report has been provided to you
today. The report concluded that the low levels of hydrogen sulfide detected at monitoring
stations did not pose a public health risk, when compared to several health standards and
guidelines. Our operations have continued to be consistent with applicable standards. The report
also notes that ambient levels of hydrogen sulfide, sulfur dioxide, ammonia and other agents
from volcanic emissions should be assessed for long-term health impacts to residents.
PGV is supportive of efforts to study potential health impacts around our facility, the East
Rift Zone and the South Rift Zone. We are committed to working with the agencies to determine
the causes of these complaints. But concluding that PGV's operations are the cause seems
unwarranted at this time.
Post Office Box 30 - 14-3860 Kapoho-Pahoa Roadon,m. Na. .7/°.147 Pahoa, Hawaii 96778 —
Tel (808) 965-6233 - Fax (808) 965-7254 Ref. To:
Ref. Date UN 06
Punageothermalventure.com
In conclusion, it is our request that the Council allow PGV the opportunity to present
information regarding the safety of PGV's operations, and that the Council invite HDOH to
provide the Council with its assessment of PGV's compliance with HDOH health standards.
Thank you for your time and consideration. Mahalo.
.....L.:1 L J.IJI..u� CG '' e 11 10`y �,t,/UK`J 1!`I WH1Plt.H 1= J n 14 6 L 7 G :1 •J'1 1'V}�,1/1�. �' ,U J.
• ,�6tWKry.,
DEPARTMENT OF HEALTH&HUMAN SERVICES
, Public Health tea
r �tiq
a,iV fi Agency rasc rycss
0'1 IJc i l' ta . T7R tor
January 5, 1998 " :,Z1't !' nl...%l.:i
Health Consultation
PUNA GEOTHERMAL VENTURE
PAHOA (PUNA DISTRICT), HAWAII COUNTY, HAWAII
CERCLIS NO. HID984469536
DECEMBER 22, 1997
U.S. DEPARTMENT OF HEALTH AND HUMAN SERVICES
Agency for Toxic Substances and Disease Registry
Division of Health Assessment and Consultation
Atlanta, Georgia
_nip! LL 4U P. /1ZG r 1.0
n1 C.C. JO 11.1Y 111 wr111'th ( l ,U=1
•
HEALTH CONSULTATION
PUNA GEOTHERMAL VENTURE
PAHOA (PUNA DISTRICT), HAWAII COUNTY, HAWAII
CERCLIS NO. HM984469536
Prepared by;
Exposure Investigation and Consultation Branch
Division of Health Assessment and Consultation
Agency for Toxic Substances and Disease Registry
YL1 •YJratt f_L JV li AV ,,.Wf�J ill WI"1Al IVI'1Va v1I • ry r Vr 1 •JAL' 1 •rV
Health Consultation: A Note of Explanation
An ATSDR health consultation is a verbal or written response from ATSDR to a specific request
for information about health risks related to a specific site, a chemical release, or the presence
of hazardous material. in order to prevent or mitigate exposures, a consultation may lead to
specific actions,such as restricting use of or replacing water supplies;intensifying environmental
sampling; restricting site access; or removing the contaminated material.
In addition, consultations may recommend additional public health actions, such as conducting
health surveillance activities to evaluate exposure or trends in adverse health outcomes;
conducting biological indicators of exposure studies to assess exposure; and providing health
education for health care providers and community members. This concludes the health
consultation process for this site, unless additional information is obtained by ATSDR which, in
the Agency's opinion, indicates a need to revise or append the conclusions previously issued.
You May Contact ATSDR TOLL TREE at
1-800-447-1544
or
Visit our Home Page at: httpi/atsdrl.atsdr.cdc.gov:/8080
• yam, �.,,r„� uu .,u aa•lu ..,w�. LI1 wnitItr�v1� Jrnv LL 7v 7 .4V f.,/1C/V f V.J
4
BACKGROUND AND STATEMENT OP ISSUES
The Hawaii Department of Health (HDOH). asked the Agency for Toxic
Substances and Disease Registry (ATSDR) to assess the threat to
public health posed by releases of hydrogen sulfide from the Puna
Geothermal Venture.
The Puna District of the Island of Hawaii is an active volcanic
area where natural emissions of steam, sulfur dioxide, carbon
dioxide, and traces of other gases occur continuously, but
variably. Beginning in April 1976, geothermal wells have been
drilled in the area for use in generating electric power. The
Puna Geothermal Venture (PGV) geothermal plant generates up to
25% of the Island of Hawaii's electricity.
During operation of the geothermal wells, gases may be released
to the atmosphere. These gases include carbon dioxide, hydrogen
sulfide, ammonia, and trace amounts of mradon. The emission of
hydrogen sulfide gas is considered to be the most important
public health problem related to the operation of these
geothermal wells [1] . Since hydrogen sulfide is heavier than
air, it can accumulate in low-lying areas during temperature
inversions or when .prevailing trade winds are calm.
The closest house to the PGV power plant is located about 1800
feet to the southeast in Lanipuna Gardens . Leilani Estates, a
large residential community, is located west of the plant.
Residential lots in this subdivision range in size from 2 to S
acres. There are about 3, 900 residential lots within a one-mile
radius of the plant, and houses have been built on about 140 of
the lots [2) .
The HDOH provided ATSDR with ambient air monitoring data
collected near the' PGV facility. The Air Quality Monitoring
Program of the HDOH operates two air monitoring stations in
residential areas near the PGV facility: the Lanipuna air
monitoring station, which is located about 450 feet southeast of
PGV, and the Leilani station, which is located about 3300 feet
southwest of PGV. The maximum concentrations of hydrogen sulfide
detected at these stations from January 1996 to April 1997 is
summarized in Table 1. During this time period, the maximum peak
concentration of hydrogen sulfide was 20 parts per billion (ppb) ,
and the maximum 1-hour concentration was 5.5 ppb. Most of the
hourly hydrogen sulfide levels were non-detectable or less than
1 ppb.
2
ucr .u ere ��...?s.:._•.ly .k; 4D tt,.wril.vvi oiL • J'HN 11 V:41 P.•.5!lab P .06
ATSDR also reviewed air monitoring data from the Lava Tree
monitoring station, which is located about 1.5 miles upwind
(northwest) of the PGV facility. From the time period January
1996 through September 1997, the maximum 1-hour air concentration
of hydrogen sulfide detected at this station was 4 ppb.
PGV operates three ambient air monitoring stations along the
fence line of their facility; monitoring data from these
stations are summarized in Table 2. During the time period,
November 1995 through January 1997, the maximum 1-hour
concentration of hydrogen sulfide detected was 46. 9 ppb on
October 4, 1996. (The 1-hour, off-site level measured during
this event was 20 ppb. ) ATSDR also reviewed PGV incident
reports, which document leaks and releases of hydrogen sulfide
during plant operations. ATSDR was provided .with 29 incident
reports that spanned the time period, June 22', 1996 to July 22,
1997. The maximum peak concentration of hydrogen sulfide
detected during a release event was 301. 7 ppb (October 4, 1996) ;
the second highest peak concentration was 33. 66 ppb (June 19,
1997) .
.DISCUSSION
Exposure to high concentrations of hydrogen sulfide can cause
well-documented, adverse health effects. At high concentrations
(500-1, 000 parts per million (ppm] ) , hydrogen sulfide acts
primarily as a systemic poison, causing unconsciousness and death
by respiratory paralysis. At lower concentrations (50-500 ppm) ,
it acts as a respiratory irritant, which can lead to pulmonary
edema upon exposure to concentrations in excess of 250 ppm.
Exposure to hydrogen sulfide concentrations of 20-50 ppm may
cause eye irritation and conjunctivitis. The occupational Safety
and Health Administration (OSHA) has 'established an occupational
standard of 10 ppm in the workplace to protect against eye
irritation and conjunctivitis.
•
The health effects of chronic, low-level exposure to hydrogen
sulfide have not been well-defined. Several epidemiological
studies have examined the health impact of mid to high level
hydrogen sulfide exposure in workers and residents exposed from
oil refineries, paper pulp mills, and other industrial sources
(3] . These studies have reported respiratory, ocular, and
neurological effects in exposed individuals. However,
interpreting the findings of these studies is hampered by
inadequate data for the exposure levels of hydrogen sulfide,
inability to distinguish between the effect of high-level acute
3
J 1 � {„( JZ P.7'12r t" .11(
• •✓ cc 70 11•14 I.VVK WHl1'ILH V L
•
•
•
exposures vs. low -level chronic exposures, concurrent exposures
to other organic sulfur compounds, and the subjective nature of
some of the health endpoints.
In a recent study, health effects and neurophysiological function
were studied in former workers and nearby residents who were
exposed to hydrogen sulfide from a desulfurization unit at an oil
refinery (41 . The study reported that exposed individuals were
more likely to demonstrate persistent alterations in
neurobehavioral function. However, several aspects of the study
confound interpretation of the findings: (1) To create an
"exposed" cohort, neighborhood residents with relatively low
level exposure were grouped together with ex-workers who likely
had much higher exposures. (2) Exposure data were sparse.
Ambient air data were available for only one week. During this
week, hydrogen sulfide levels were 10-100 ppb, but several other
air contaminants were also detected (dimethyl sulfide,
mercaptans, hydrocarbons, vanadium [V203) , thioglycolic acid, and
sulfur dioxide) . On site, high air levels of hydrogen sulfide
were detected (0-8, 800 ppb) , as well as high concentrations of
other contaminants. Therefore, it cannot be determined whether
the effects observed in this study were due to hydrogen sulfide
or to other chemicals from the site.
To date, no epidemiological study has demonstrated that chronic
exposure to hydrogen sulfide at concentrations in the low ppb
range has caused adverse health effects.
ATSDR has developed Minimal Risk Levels (MRL) of 500 ppb for
acute (1-14 days) and 90 ppb for intermediate (15-364 days)
exposures to hydrogen sulfide (3] . MRLs are defined as an
estimate of daily exposure of a human, being to a chemical that is
likely to be without risk of deleterious effects
(nonearoinogenic) over a specified duration of exposure.
The EPA developed a Reference Concentration (RfC) of 1 pg/m'
(0.7 ppb) for chronic exposure to hydrogen sulfide. This value
was derived from an experimental study in which nasal
inflammation was observed in mice that were exposed to 80 ppm
hydrogen sulfide for 90 days. This RfC is very conservative,
since it incorporates an uncertainty factor of 1,000. There is
no direct evidence that exposure to hydrogen sulfide in the low
ppb range causes adverse health effects in any animal, including
humans.
4
j r .LJn11 cc 7o 11•lc I.UtMS 111 wH111t140 z JHN L1 'y25 V :41 P.8/121b F .08
After being absorbed into the blood, hydrogen sulfide is rapidly
metabolized - primarily by oxidation to sulfate, which is then
excreted in the urine (3) . Because of the rapid metabolism and
elimination of hydrogen sulfide, it would not accumulate in the
_ body during chronic exposure.
Ambient air concentrations of hydrogen sulfide in residential
areas near the PGV are typically less than 1 ppb. These levels
are similar to naturally-occurring, background levels (0 . 11 to
0.33 ppb) that have been detected in ambient air at other
locations (3) . There is no toxicological evidence that chronic
exposure to these levels of hydrogen sulfide would have an
adverse impact on public health.
Air monitoring data indicate that hydrogen sulfide releases from
operations at PGV have resulted in off-site peak concentrations
of hydrogen sulfide of 20 ppb for a few minutes duration, or
hourly concentrations of 2-5 ppb. These concentrations are less
than ATSDR's acute MAL of 500 ppb and intermediate MRL of
90 ppb and do .not pose a public health hazard. The maximum
concentrations of hydrogen sulfide detected on-site at PGV
monitors (peak - 302 ppb, 1-hour - 47 ppb) are also below ATSDR' s
acute MRL and would not be expected to pose a health hazard.
Hydrogen sulfide is a colorless gas with an odor suggesting
rotten eggs. Humans vary in their ability to smell hydroqen
sulfide, and individual odor thresholds range from 3-12 ppb or
higher. Hydrogen sulfide was sporadically detected at
residential air monitoring stations at concentrations that exceed
the odor threshold. This has likely contributed to the numerous
citizen complaints over air quality near the facility.
The upwind, ambient air monitoring station at Lava Tree recorded
hourly hydrogen sulfide levels comparable to those detected at
the Lanipuna and Leilani stations. Therefore, hydrogen sulfide
releases from volcanic activity on the island may be contributing
to background levels of hydrogen sulfide in the Puna District.
Significant releases of hydrogen sulfide reportedly occurred at
the PGV facility in 1991 and 1993. However, the public health
impact of these releases can not be assessed, since no ambient
air data are available for these events. As part of their
Emergency Response Plan, PGV modelled air .concentrations of
hydrogen sulfide that could result from an accidental release of
hydrogen sulfide from the facility during worst case conditions.
They estimated that a hydrogen sulfide concentration of 12,786
ppb could occur at a distance of 1, 300 feet from the plant. This
5
M..1 r717 cc. 70 11.1J W%JflJ 111 ff111 IVi1 --'
1
concentration exceeds OSHA's Permissible Exposure Level of 10 ppm
for an 8-hour exposure for workers; however, it is less than the
American Industrial Hygiene Association's Emergency Response
Planning Guideline-2 (ERPG-2) of 30 ppm. An ERPG-2 is defined as
"the maximum airborne concentration below which it is believed•
nearly all individuals could be exposed for up to 1 hour without
experiencing or developing irreversible or other serious health
effects or symptoms that could impair their abilities to take
protective action. " The HAOH indicated that an evacuation of the
area would be initiated if an unplanned release of hydrogen
sulfide resulted in air levels of greater than 1, 000 ppb (2] .
ATSDR concurs that such action would be protective of public
health.
No information was available for ambient air levels of other
gases (e.g. , sulfur dioxide, ammonia) that are known to be
present in volcanic emissions. Therefore, the potential health
impact of these other gases, if they are present, can not be
assessed.
CONCLUSIONS
(1) The concentrations of hydrogen sulfide detected in air at
monitoring stations in residential areas near the Puna
Geothermal Venture do not pose a public health hazard.
(2) The HDOH emergency level of 1,000 ppb hydrogen sulfide for
evacuation in the event of an unplanned release is
protective of pubic health.
=COMMENDATIONS
(1) None <.,4c or.q(Kenneth G. Orloff, Ph.D.., DART
Senior Toxicologist
6
-.., •.Y JPlu 1 4L .,uJ 11 iJ vrVVIlJ li 1 Vlrlil Il_I V - - - - --- - ..._ ___
Table 1: Maximum 1-hour and peak hydrogen sulfide (H4S)
concentrations detected at Hawaii Department of Haalth off-site, '
. ambient air monitoring stations
[Date H S concent=1 Station
January 1996 3.2 ppb (hour) Lanipuna
February 1996 1.7 ppb (hour) Lanipuna
March 1996 3.3 ppb (hour) Leilani
April 1996 3.5 ppb (hour) Leilani
May 1996 2.9 ppb (hour) Leilani
June 1996 5.5 ppb (hour) Lanipuna
July 1996 1.9 ppb (hour) Leilani
August 1996 10 ppb (peak), Lanipuna
•
1.7 ppb (hour) Leilani
September 1996 7.5 ppb (peak) Lanipuna
3.3 ppb (hour) Lanipuna
October 1996 20 ppb (peak) Lanipuna
2 .7 ppb (hour) Lanipuna
November 1996 2. 6 ppb (hour) Lanipuna
December 1996 2.2 ppb (hour) Lanipuna
January 1997 2.0 ppb (hour) Lanipuna
February 1997 2.3 ppb (hour) Lanipuna
March 1997 3.9 ppb (hour) Lanipuna
April 1997 1.6 ppb (hour) Lanipuna
ppb - parts per billion
(1) - this finding was of questionable validity because of the
symmetry of the peak and the lack of other traces around the peak
7
.ern. .... .ru .+•t•+ ....VVnJ 111 WM11'Ic_i-,v1L Jrtiv tL ,0 , •44J P.11/10 r . 1i
Table 2: Maximum 1-hour hydrogen sulfide (H=3)' concentrations
detected at PGV on-site, ambient air monitoring stations
Date H2S concentration Station
November 1995 3.3 ppb B
. December 1995 6. 0 ppb B and C
January 1996 5.1 ppb A
February 1996 3. 3 ppb
March 1996 2. 6 ppb
April, 1996 5, 8 ppb
May 1996 1.4 ppb
June 1996 12.4 ppb A
July 1996 2 . 8 ppb g
August '1996 1.3 ppb
September 1996 19.8 ppb A
October 1996 46. 9 ppb A
November 1996 3. 6 ppb C
December 1996 2.7 ppb A
January 1997 2 .7 ppb A
ppb - parts per billion
A SE station, topographically down 'gradient from PGV facilities
B SW station, in the prevailing downwind direction from the
facility
C = W station, selected because of its proximity to a residential
neighborhood
8
11c.r •UN^':.r-f....?4.J.l 1;I LUU$ 111 WH.IltHO1.: JRIV Lh 70 7 •'I'I Q,12,12 r • 1i
REFERENCES
(1) Hawaii Department of Health; Health Status of County of
Hawaii Populations Exposed to Geothermal and Volcanic
Emissions - Preliminary Report; March 1991.
(2) Barbara A. Brooks; Health Risk Assessment: Evaluation of
potential adverse health effects from short-term exposure to
hydrogen sulfide resulting from an unplanned release from
geothermal wells in Puna, Hawaii; The Hawaii State
Department of Health; August 16, 1993 .
(3) Agency for Toxic Substances and Disease Registry;
Toxicological Profile for Hydrogen Sulfide, Draft;
September 1997.
(4) Kaye Kilburn and Raphael Warshaw; Hydrogen sulfide and
reduced-sulfur gases adversely affect neurophysiological
functions; Toxicology and Industrial Health 11 185-197
(1995) .
•
•
9