Loading...
HomeMy WebLinkAboutREP PWC 320 10/09/1984 1980-1984 • µ. : 411 ��,b sy .li • REPORT OF THE COMMITTEE ON PUBLIC WORKS DATE : October 9, 1984 - _-__Re_: = Comm: 1723 TIME: 9 :07 a.m PLACE: County Councilroom, Hilo Chairman and Members Hawaii County Council Hilo, Hawaii Your Committee on Public Works, to which .was referred Bill No. 1133, reports as follows: The purpose of Bill 1133 is to update the Building Code of the County of Hawaii . To do so, the Bill proposes that the County adopt the 1982 Edition of the Uniform Building Code (UBC 82) in place of the 1976 Edition of the Uniform Building Code (UBC 76) , as the standard for building work within the County. The Bill also proposes for adoption a number of amendments which tailors the UBC 82 to local and climatic requirements . Your Committee has received written testimony (Communication 1723 ) from the Department of Public Works indicating that the proposed code and its amendments have been reviewed by the Building Code Review Committee. This Review Committee is composed of licensed building contractors , a structural engineer, a civil engineer, an architect, a material supplier, a representative of the building trades , a representative from the community college and a representative of our Planning Department. Communication 1723 also highlights the significant differences • between the existing Building Code and that proposed by Bill 1133. These differences include: 1. Provisions which allow buildings to be altered, repaired, or modified without complying with all of the provisions of the Code so long as the new work complies with the Code and the buildings are not made to become unsafe or overloaded. 2. A revised fee schedule based on area rather than valuation. 3 Provisions which allow one toilet for use by both sexes of the handicapped. PWC REPORT No. 320 ADOPTED: .00T. 1 7 1984 411 • 4' 'moi PWC-320 Page 2 October 9, 1984 , • 4. Fire protective provisions: (a) requiring one-hour fire-resistive walls in apartment buildings between apartments, common use laundry, storage rooms and; (b) alarm systems in all apartment houses containing more than 15 units 5 . Provisions requiring smoke detectors in basement areas and that these detectors be connected to detectors in sleeping areas. 6 . Deleting the provisions for Fire Zones and Fire Districting. 7 . Adopting provisions for Factory Built Housing.. Your Committee on Public Works concurs that Bill 1133 updating the County Building Code is in the best interest of the people and recommends passage of this Bill by the County Council. (ABSENT AND EXCUSED) MERLE K. LAI, CHAIRWOMAN ir k.)••44-1a.._- W IAM S. KAWAHARA, VICE CHR. . FRANK DE LUZ, III, MEMBER 4P(446---04-4:, TAKASHI DOMINGO, MEMBER, •RRA E JI: U, MEMBER LA/GM