Loading...
HomeMy WebLinkAboutPV ELECTRICAL DRAWING EXAMPLE_rev15TH AVESHEET INDEXPV-1 : COVER PAGEPV-2 : PLOT / ARRAY LAYOUTPV-3 : SINGLE LINE DIAGRAMPV-4 : ELEVATION DETAILPV-5 : PROJECT SIGNAGEATTACHMENTS- PV MODULE SPEC SHEET- MICRO-INVERTER SPEC SHEET- IQ COMBINER 3C-ES- ENPOWER SMART SWITCH- ENCHARGE 10- ENCHARGE 3- RACKING SPEC SHEETVICINITY MAP3D MODELTITLE SHEETT01GENERAL NOTES:ALL WORK TO BE DONE INACCORDANCE WITH THEFOLLOWING CODES:2017 NATIONAL ELECTRIC CODE2018 INTL. RESIDENTIAL CODE2018 INTL. BUILDING CODE2019 INTL. ENERGY CODE2012 INTL. FIRE CODEAS ADOPTED BY THE STATE OF HAWAII;ALL OTHER ORDINANCES ADOPTED BYLOCAL GOVERNING AGENCIES.AHJ: CITY OF KEAAUPROJECTDESIGNER : YAO OUATTARACREATED : 01/29/2022REVISED : N/AISSUANCE : PLANSETSKYTA CONSTRUCTION CSLB# CT-308952045 LAUWILIWILI ST. STE# 203KAPOLEI, HI, 96707ENGINEER OF RECORDSIGNATURE WITH SEALFOR DPW PERMIT USE ONLYFOR DPW USE ONLY EXP 4/30/2022THIS WORK WAS PREPARED BY ME OR UNDER MY SUPERVISION ANDCONSTRUCTION OF THIS PROJECT WILL BE UNDER MY OBSERVATION.PLANS PROVIDED BY:YAO OUATTARA, Electrical and Solar EngineerNabcep certified : Cert# PV-042217-016452Under Supervision of the Engineer of Record.The designs and material shown is for review purposes only.YAO OUATTARA retains all title, ownership, and intellectualproperty rights to the material contained herein.SITE DIAGRAMEXISTING HOMEPATRICIA MABIE15-2058 15TH AVEKEAAU, HI 96749GPS: 19.568875,-154.9508149TMK:150240040000PROJECT DETAILSPROGRAM : CGS+(30) REC TWINPEAK 4 SERIES REC365TP4 365W PV MODULES(30) IQ7+ MICRO-INVERTERS(1) IQ COMBINER 3C-ES(1) ENPOWER SMART SWITCH(2) ENCHARGE 10(1) ENCHARGE 3DC SYSTEM SIZE: 10.95 KW DC (STC)AC SYSTEM SIZE: 8.85 KW ACINSTALL TYPE: COMPOSITE SHINGLE ROOFRAFTERS: 2X6'S @ 24" OCDigitally signed by Bruce A RussellDN: C=US, E=barthurr@cox.net, O="State of the Art SOTA, P.L.L.C.", OU=Engineering, CN=Bruce A RussellReason: I am approving this document.Contact Info: 8089380229Date: 2022.02.11 16:42:27-06'00'2018ELECTRICAL ENGINEER CERTIFICATION HERES A M P L E 15TH AVEEXISTING UTILITY METERWITH 200A MAIN SERVICE PANELPROPOSED NEW UTILITY REQUIRED24/7 SOLAR AC DISCONNECTNEW ENPOWER SMART SWITCHCGS + PV PRODUCTION METERNEW 200A BACK UP LOAD CENTERPROPOSED NEW UTILITY REQUIRED24/7 BATTERY AC DISCONNECTNEW IQ COMBINERNEW (2) ENCHARGE 10 BATTERIESPROPERTY LINENEW (1) ENCHARGE 3 BATTERIESNOTE: ALL PROPERTY LINESARE AN APPROXIMATION.SITE PLANPV01PROJECTDESIGNER : YAO OUATTARASKYTA CONSTRUCTION CSLB# CT-308952045 LAUWILIWILI ST. STE# 203KAPOLEI, HI, 96707FOR DPW USE ONLYPLANS PROVIDED BY:YAO OUATTARA, Electrical and Solar EngineerNabcep certified : Cert# PV-042217-016452Under Supervision of the Engineer of Record.The designs and material shown is for review purposes only.YAO OUATTARA retains all title, ownership, and intellectualproperty rights to the material contained herein.PLAN VIEW - PV EQUIPMENT LOCATIONSEXISTING HOMEENGINEER OF RECORDSIGNATURE WITH SEAL EXP 4/30/2022THIS WORK WAS PREPARED BY ME OR UNDER MY SUPERVISION ANDCONSTRUCTION OF THIS PROJECT WILL BE UNDER MY OBSERVATION.REVISED : N/AISSUANCE : PLANSETCREATED : 01/29/2022PATRICIA MABIE15-2058 15TH AVEKEAAU, HI 96749GPS: 19.568875,-154.9508149TMK:150240040000Digitally signed by Bruce A RussellDN: C=US, E=barthurr@cox.net, O="State of the Art SOTA, P.L.L.C.", OU=Engineering, CN=Bruce A RussellReason: I am approving this document.Contact Info: 8089380229Date: 2022.02.11 16:42:27-06'00'ELECTRICAL ENGINEER CERTIFICATION HERES A M P L E ARRAY(30) MODULES1 = STRING 12 = STRING 23 = STRING 3PITCH : ~20°AZIMUTH : ~137°3' PATHWAY FROM ROOFEDGE TO RIDGE (TYP.)3' CLEAR SETBACK ON BOTHSIDES OF RIDGE (TYP.)1111111111222222222233333333331122VARIESIRONRIDGE RAILIRONRIDGE FLASHFOOTXWWCCH10.4J10.4RIRONRIDGE RAILPV MODULEL0.4xL MAX.LE10.0G10.0J10.4IRONRIDGE STOPPER SLEEVEIRONRIDGE UNIVERSALFASTENING OBJECTIRONRIDGE FLASH FOOTIRONRIDGE UNIVERSALFASTENING OBJECT1"(E) ROOFMEMBRANEIRONRIDGEFLASHFOOTIRONRIDGERAILPV MODULE,BY OTHERS(E) BUILDINGSTRUCTURE(E) ROOFMEMBRANEIRONRIDGEFLASHFOOTIRONRIDGERAILPV MODULE,BY OTHERS(E) BUILDINGSTRUCTUREPV MODULE FRAMEIRONRIDGE RAILIRONRIDGE STOPPER SLEEVEIRONRIDGE UNIVERSALFASTENING OBJECT1"PV MODULE FRAMEIRONRIDGE RAILIRONRIDGE STOPPERSLEEVEIRONRIDGE UNIVERSALFASTENING OBJECT1"PV MODULE FRAMEIRONRIDGE RAILIRONRIDGE UNIVERSALFASTENING OBJECTPV MODULE FRAMEIRONRIDGE UNIVERSALFASTENING OBJECT38"ROOF PLANPV02PROJECTDESIGNER : YAO OUATTARASKYTA CONSTRUCTION CSLB# CT-308952045 LAUWILIWILI ST. STE# 203KAPOLEI, HI, 96707STRUCTURAL CALCULATION:MODULE WEIGHT 43 LBS# OF MODULES 30TOTAL MODULE WEIGHT 1290 LBSTOTAL AREA (SQ FT) 589WEIGHT / ATTACHMENT 30.29 LBSRACKING WEIGHT 308.06 LBSTOTAL SYSTEM WEIGHT 1598.06 LBSDISTRIBUTED WEIGHT 2.71 PSFROOF INFORMATIONTYPEPITCHRAFTER# STORYCOMPOSITE SHINGLE ROOF~ 20°2 X 6 @ 24" OCONE-STORYARRAY INFORMATIONARRAYARRAYMODULESTILTORIENTATION30 20° 137°PLANS PROVIDED BY:YAO OUATTARA, Electrical and Solar EngineerNabcep certified : Cert# PV-042217-016452Under Supervision of the Engineer of Record.The designs and material shown is for review purposes only.YAO OUATTARA retains all title, ownership, and intellectualproperty rights to the material contained herein.ROOF DIAGRAM - PV MODULE LAYOUTEXISTING HOMEREVISED : N/AISSUANCE : PLANSETNOTE : PV PANEL PLACEMENT SHALL COMPLY WITH 2018 IRC SEC 324.6.1 & 324.6.2R324.6.1 PathwaysNot fewer than two pathways, on separate roof planes from lowest roof edge to ridge and not less than 36 inches (914 mm) wide, shall beprovided on all buildings. Not fewer than one pathway shall be provided on the street or driveway side of the roof. For each roof plane with aphotovoltaic array, a pathway not less than 36 inches wide (914 mm) shall be provided from the lowest roof edge to ridge on the same roofplane as the photovoltaic array, on an adjacent roof plane, or straddling the same and adjacent roof planes. Pathways shall be over areascapable of supporting fire fighters accessing the roof. Pathways shall be located in areas with minimal obstructions such as vent pipes, conduit,or mechanical equipment.R324.6.2 Setback at RidgeFor photovoltaic arrays occupying not more than 33 percent of the plan view total roof area, not less than an 18-inch (457 mm) clear setback isrequired on both sides of a horizontal ridge. For photovoltaic arrays occupying more than 33 percent of the plan view total roof area, not lessthan a 36-inch (914 mm) clear setback is required on both sides of a horizontal ridge.CREATED : 01/29/2022PATRICIA MABIE15-2058 15TH AVEKEAAU, HI 96749GPS: 19.568875,-154.9508149TMK:150240040000FLASHFOOT DETAIL SIDEFLASHFOOT DETAIL FRONTMID CLAMP AND END CLAMP DETAILSIRONRIDGE SIDE VIEW FLASHFOOT MOUNTIRONRIDGE FRONT VIEW FLASHFOOT MOUNT, PORTRAIT MODULEFOR DPW USE ONLYELECTRICAL ENGINEER CERTIFICATION HERES A M P L E GMECO METER #: 157555EXISTING UTILITY METER WITH200A MAIN SERVICE PANEL200A MAIN BREAKER120/240V 1ɸ 3WUTILITYMETER13AC BRANCH CIRCUIT: MICRO-INVERTER OUTPUT TO JUNCTION BOXFREE AIRN/AN/A12.1A20A 2PINTEGRATED IN ENPHASE SYSTEMN/A12.1A15.12A35A26.6A23AC BRANCH CIRCUIT: JUNCTION BOXTO IQ COMBINER10.76NEC ELECTRICAL CALCULATIONS FOR CONDUCTORSIDTYPICALDESCRIPTIONCONDUCTORNo OFCONDUC. INCONDUITCONDUIT FILL %RATEDAMPSOCPDEGCTEMPCORRFACTORCONDUIT FILLFACTORCONTCURRENTBASEAMPDERATEAMPSCONDUITMAXCURRENT(125%)EstimatedConductorLengthN/AN(N)200A 2P10 AWG THWN-2,COPPER(N) SUPANEL,200A 120/240V 1ɸ 3W200A MAIN BREAKERNEMA 3R 7 641IQ COMBINER PANEL TOSMART SWITCH VIA AC DISCONNECT8 AWG THWN-2,COPPER1" DIA. EMT336.3A50A 2P10 AWG THWN-2,COPPER1.036.3A1.045.37ALess Than 30'50A50ALess than 40%56SMART SWITCH OUTPUT TO (N) 200A SUBPANELINTERIOR ENPHASEIQ COMBINER 3C-ESX-IQ-AM1-240-3C-ES125A, 120/240V , 1ɸ 3WNEMA 3RCGS+ PROGRAMEXTERIOR ACDISCONNECT60A 120/240V1ɸ 3WNEMA 3R43A13/0 AWG THWN-2,COPPER2" DIA. EMT3160A200A 2P6 AWG THWN-2,COPPER1.0160A1.0200ALess Than 30'200A200ALess than 40%ROOFTOPPASS-THROUGHBOX 1DCACDCDCACAC20A 2P15A 2PENPHASE ENVOYMONITORING20A 2PEXTERIOR ENPHASEENPOWER SMART SWITCHEP200G101-M240US00160A CONTINUOUS,120/240V , 1ɸ 3WNEMA 3R50A 2P 2 4TO EXISTING LOADS620A 2PINTEGRATED IN ENPHASE SYSTEM0.835A28A1.010 AWG THWN-2,COPPER1" DIA. EMTLess Than 40'Less than 40%SMART SWITCH OUTPUT TO (E) MAIN SERVICE PANEL13/0 AWG THWN-2,COPPER2" DIA. EMT36 AWG THWN-2,COPPER1.01.0Less Than 30'200A200ALess than 40%30A 2P20A 2PAC DC AC DC AC DC AC DC AC DC AC DC AC DC AC DC AC DC AC DC AC DC AC DC DCACDCDCACACEXTERIOR ACDISCONNECT60A 120/240V1ɸ 3WNEMA 3R50A 2P 3A55TO EXISTING LOADS1BATTERY OUTPUT : BATTERY COMBINER PANEL216A20A 2PINTEGRATED IN ENPHASE SYSTEM116A20A35A35A1.010 AWG THWN-2,COPPER1" DIA. EMTLess Than 40'Less than 40%BATTERY COMBINER PANEL TO SMART SWITCH VIA AC DISCONNECT8 AWG THWN-2,COPPER1" DIA. EMT337.3A50A 2P10 AWG THWN-2,COPPER1.037.3A1.046.62ALess Than 30'50A50ALess than 40%7(N) BATTERYCOMBINER PANEL, MLO125A,120/240V,NEMA 3R 1ɸ 3WMEXTERIOR CGS +PRODUCTIONMETER ENCHARGE 1020A 2PDCACDCDCACAC160A200A160A200A 2PIMPORTANT NOTE : PER NEC 710.15(A), THE CAPACITY OF THE SUM OF OF ALL SOURCES OFTHE STAND ALONE SUPPLY SHALL BE EQUAL OR GREATER THAN THE LOAD POSED BY THELARGEST SINGLE UTILIZATION EQUIPMENT CONNECTED TO THE SYSTEM.OTHER NOTES :1.FOR EMPOWER MAIN LUG, USE #1-350MCM, FOR SMALLERCONDUCTORS, REMOVE LUG AND USE APPROVED RING TERMINAL2.IF NOT USING IQ3C COMBINER, THEN CELLULAR KIT IS REQUIRED3.LINE FILTER REQUIRED FOR PV OUTSIDE OF MICRO-GRID4.EMPOWER SMART SWITCH, MANUFACTURER REQUIRES:4.1.MAX UTILITY OCPD : 200A4.2.MAX PV OCPD : 80A4.3.MAX BATTERY OCPD : 80A4.4.MAX BACK UP OCPD : 200A4.5.MAX GENERATOR OCPD : 60A4.6.PER UL LISTING5.ESS HOLD-DOWN REQUIRED ON ALL ESS BACK-FED BREAKERS PERNEC 710.5(E)6.PV TO ESS RATIO MUST COMPLY WITH MFR GUIDELINESEXTERIOR ENPHASEENCHARGE 3ENCHARGE-3-1P-NA1.28 KVA, 240V , 1ɸ 2W3.5 KWH, NEMA 3R(TYP.OF 1)3BAC DC AC DC AC DC AC DC AC DC AC DC AC DC AC DC AC DC AC DC AC DC AC DC AC DC AC DC AC DC AC DCEXTERIOR ENPHASEENCHARGE 10ENCHARGE-10-1P-NA3.84 KVA, 240V , 1ɸ 2W10.5 KWH, NEMA 3R(TYP. OF 2) ENCHARGE 10 ENCHARGE 3 4STRING 1(10) MODULES REC TWINPEAK 4 SERIES REC365TP 365W(10) MICRO-INVERTERS IQ7+STRING 2(10) MODULES REC TWINPEAK 4 SERIES REC365TP 365W(10) MICRO-INVERTERS IQ7+STRING 3(10) MODULES REC TWINPEAK 4 SERIES REC365TP 365W(10) MICRO-INVERTERS IQ7+12.1A12.1A15.12A3B1BATTERY OUTPUT : BATTERY COMBINER PANELBATTERY OUTPUT : BATTERY COMBINER PANEL221.3A30A 2PINTEGRATED IN ENPHASE SYSTEM121.3A26.62A35A35A1.010 AWG THWN-2,COPPER1" DIA. EMTLess Than 40'Less than 40%TO EXISTING LOADS(N)200A 2PSINGLE LINEPV03PROJECTDESIGNER : YAO OUATTARASKYTA CONSTRUCTION CSLB# CT-308952045 LAUWILIWILI ST. STE# 203KAPOLEI, HI, 96707FOR DPW USE ONLYPLANS PROVIDED BY:YAO OUATTARA, Electrical and Solar EngineerNabcep certified : Cert# PV-042217-016452Under Supervision of the Engineer of Record.The designs and material shown is for review purposes only.YAO OUATTARA retains all title, ownership, and intellectualproperty rights to the material contained herein.ENGINEER OF RECORDSIGNATURE WITH SEAL EXP 4/30/2022THIS WORK WAS PREPARED BY ME OR UNDER MY SUPERVISION ANDCONSTRUCTION OF THIS PROJECT WILL BE UNDER MY OBSERVATION.ONE-LINE - PV ELECTRICALREVISED : N/AISSUANCE : PLANSETSYSTEM AMPERAGECREATED : 01/29/2022PATRICIA MABIE15-2058 15TH AVEKEAAU, HI 96749GPS: 19.568875,-154.9508149TMK:150240040000PROJECT DETAILSPROGRAM : CGS+(30) REC TWINPEAK 4 SERIES REC365TP4365W PV MODULES(30) IQ7+ MICRO-INVERTERS(1) IQ COMBINER 3C-ES(1) ENPOWER SMART SWITCH(2) ENCHARGE 10(1) ENCHARGE 3DC SYSTEM SIZE: 10.95 KW DC (STC)AC SYSTEM SIZE: 8.85 KW ACDigitally signed by Bruce A RussellDN: C=US, E=barthurr@cox.net, O="State of the Art SOTA, P.L.L.C.", OU=Engineering, CN=Bruce A RussellReason: I am approving this document.Contact Info: 8089380229Date: 2022.02.11 16:42:28-06'00'ELECTRICAL ENGINEER CERTIFICATION HERES A M P L E ELECTRICAL SHOCK HAZARDTERMINALS ON THE LINE ANDLOAD SIDES MAY BE ENERGIZEDIN THE OPEN POSITIONNEC 706.15 (C)(4) & NEC 690.13(B)LABEL LOCATION:INVERTER(S), AC DISCONNECT(S), DC DISCONNECT(S), ACCOMBINER PANEL (WHEN APPLICABLE)DANGER!POWER SOURCE OUTPUTCONNECTION. DO NOTRELOCATE THISOVERCURRENT DEVICE.NEC 705.12 (B)(3)(2)LABEL LOCATION:ADJACENT TO PV BACKFED BREAKER (WHEN APPLICABLE).WARNING!THREE POWER SOURCESSECOND SOURCE IS PV SYSTEMTHIRD SOURCE IS BATTERY SYSTEMNEC 705.12(C) & NEC 690.59LABEL LOCATION:UTILITY SERVICE METER AND MAIN SERVICE PANELWARNING!THIS EQUIPMENT FED BYMULTIPLE SOURCES:TOTAL RATING OF ALL OVERCURRENTDEVICES EXCLUDING MAIN POWERSUPPLY SHALL NOT EXCEEDAMPACITY OF BUSBARNEC 705.12(B)(3)(3)LABEL LOCATION:COMBINER PANEL (IF APPLIABLE)WARNING!PHOTOVOLTAIC POWER SOURCENEC 690.31(D)(2)LABEL LOCATION:INTERIOR AND EXTERIOR DC CONDUIT EVERY 1O FT, AT EACH TURN, ABOVE ANDBELOW PENETRATIONS, ON EVERY JB/PULL BOX CONTAINING DC CIRCUITS. (WHENAPPLICABLE)RAPID SHUTDOWN FORSOLAR PV SYSTEMNEC 690.56(C)(2)LABEL LOCATION:ON OR NO MORE THAN 1 M (3 FT) FROM THE SWITCHTURN RAPID SHUTDOWNSWITCH TO THE "OFF" POSITIONTO SHUT DOWN PV SYSTEMAND REDUCE SHOCK HAZARD INTHE ARRAYSOLAR PV SYSTEM EQUIPPED WITHRAPID SHUTDOWNSOLAR ELECTRICPV PANELSIFC 605.11.3.1(1) & NEC 690.56(C)LABEL LOCATION:ON OR NO MORE THAN 1 M (3 FT) FROM THE SWITCH PHOTOVOLTAIC AC DISCONNECTRATED AC OUTPUT CURRENT: 36.3ANOMINAL OPERATING AC VOLTAGE: 240VNEC 690.54LABEL LOCATION:AC DISCONNECT(S), PHOTOVOLTAIC SYSTEM POINT OFINTERCONNECTIONNOTES AND SPECIFICATIONS:ALL LABELS WILL BE ON RESISTANT MATERIAL SUITABLE FOR THE ENVIRONMENT.ALL LABELS SHALL HAVE A RED BACKGROUND WITH MIN. 3/8" WHITE LETTERING· SIGNS AND LABELS SHALL MEET THE REQUIREMENTS OF THE NEC 2020 ARTICLE110.21(B), UNLESS SPECIFIC INSTRUCTIONS ARE REQUIRED BY SECTION 690, ORIF REQUESTED BY THE LOCAL AHJ.· SIGNS AND LABELS SHALL ADEQUATELY WARN OF HAZARDS USING EFFECTIVEWORDS, COLORS AND SYMBOLS.· LABELS SHALL BE PERMANENTLY AFFIXED TO THE EQUIPMENT OR WIRINGMETHOD AND SHALL NOT BE HAND WRITTEN, UNLESS PORTIONS OF LABELS ORMARKINGS ARE VARIABLE, OR THAT COULD BE SUBJECT TO CHANGES, SHALLBE PERMITTED TO BE HAND WRITTEN AND SHALL BE LEGIBLE.· LABEL SHALL BE OF SUFFICIENT DURABILITY TO WITHSTAND THE ENVIRONMENTINVOLVED.· SIGNS AND LABELS SHALL COMPLY WITH ANSI Z535.4-2011, PRODUCT SAFETYSIGNS AND LABELS, UNLESS OTHERWISE SPECIFIED.· DO NOT COVER EXISTING MANUFACTURER LABELS. BATTERY AC DISCONNECTRATED AC OUTPUT CURRENT: 37.3ANOMINAL OPERATING AC VOLTAGE: 240VNEC 690.54LABEL LOCATION:AC DISCONNECT(S), PHOTOVOLTAIC SYSTEM POINT OFINTERCONNECTIONEXISTING UTILITY METERWITH 200A MAIN SERVICE PANELPROPOSED NEW UTILITY REQUIRED24/7 SOLAR AC DISCONNECTCGS + PV PRODUCTION METERPROPOSED NEW UTILITY REQUIRED24/7 BATTERY AC DISCONNECTELECTRICAL NOTES:1. ROOFTOP MOUNTED PHOTOVOLTAIC PANELS AND MODULES SHALL BE TESTED, LISTED AND IDENTIFIED BY RECOGNIZED TESTING LABORATORY2. SOLAR SYSTEM SHALL NOT COVER ANY PLUMBING OR MECHANICAL VENTS3. MODULES AND SUPPORT STRUCTURES SHALL BE GROUNDED UNLESS RACKING HAS INTEGRATED GROUND.4. REMOVAL OF AN INTERACTIVE INVERTER OR OTHER EQUIPMENT SHALL NOT DISCONNECT THE BONDING CONNECTION BETWEEN THE GROUNDINGELECTRODE CONDUCTOR AND THE PHOTOVOLTAIC SOURCE AND/OR OUTPUT CIRCUIT GROUNDED CONDUCTORS.5. ALL PV MODULES AND ASSOCIATED EQUIPMENT AND WIRING SHALL BE PROTECTED FROM PHYSICAL DAMAGE.6. LIVE PARTS OF PV SOURCE CIRCUITS AND PV OUTPUT CIRCUITS OVER 150V TO GROUND SHALL NOT BE ACCESSIBLE TO OTHER THAN QUALIFIEDPERSONS WHILE ENERGIZED.7. INVERTER IS EQUIPPED WITH INTEGRATED DC DISCONNECT, THUS PROVIDING GROUND FAULT PROTECTION8. ALL CONDUCTORS SHALL BE COPPER AND 75 DEG RATED9. A SINGLE CONDUCTOR SHALL BE PERMITTED TO BE USED TO PERFORM THE MULTIPLE FUNCTIONS OF DC GROUNDING, AC GROUNDING ANDBONDINGBETWEEN AC AND DC SYSTEMS. 10.NON-CURRENT CARRYING METAL PARTS OF EQUIPMENT SHALL BE EFFECTIVELY BONDED TOGETHER. BOND BOTHENDS OF RACEWAYS.DIRECTORY MAP OF DISCONNECTING MEANSPOWER TO THIS BUILDING IS ALSO SUPPLIED FROM THE FOLLOWING SOURCE WITH DISCONNECTS LOCATED AS SHOWN:FOR DPW USE ONLYSIGNAGEPROJECTSKYTA CONSTRUCTION CSLB# CT-308952045 LAUWILIWILI ST. STE# 203KAPOLEI, HI, 96707FOR DPW USE ONLYPV05PLANS PROVIDED BY:YAO OUATTARA, Electrical and Solar EngineerNabcep certified : Cert# PV-042217-016452Under Supervision of the Engineer of Record.The designs and material shown is for review purposes only.YAO OUATTARA retains all title, ownership, and intellectualproperty rights to the material contained herein.REVISED : N/AISSUANCE : PLANSETDESIGNER : YAO OUATTARACREATED : 01/29/2022PATRICIA MABIE15-2058 15TH AVEKEAAU, HI 96749GPS: 19.568875,-154.9508149TMK:150240040000EXP 4/30/2022THIS WORK WAS PREPARED BY ME OR UNDER MY SUPERVISION ANDCONSTRUCTION OF THIS PROJECT WILL BE UNDER MY OBSERVATION.Digitally signed by Bruce A RussellDN: C=US, E=barthurr@cox.net, O="State of the Art SOTA, P.L.L.C.", OU=Engineering, CN=Bruce A RussellReason: I am approving this document.Contact Info: 8089380229Date: 2022.02.11 16:42:29-06'00'ELECTRICAL ENGINEER CERTIFICATION HERES A M P L E