R202
Townhouse and Townhouse Unit
TOWNHOUSE. Building that contains three or more attachedtownhouse units.
TOWNHOUSE UNIT. A single-family dwelling unit in a townhousethat extends from foundation to roof and that has a yard orpublic way on not less than two sides
R202
Intermodal Shipping Containers
Provisions for construction with intermodal shippingcontainers added by referencing IBC Section 3315 andICC G5
– Guideline for the Safe Use of ISO Shipping ContainersRepurposed as Buildings and Building Components
R301.1.4
Meryll Ricardo
CFO
Wind Design
Updated wind speed maps
match IBC and ASCE 7 maps with
a large portion of the country
having wind speeds less than
115mph
R301.2.1
Story Height
R301.3
Townhouse Common Wall
Common walls
separating
townhouses can
terminate at the inside
of exterior walls
-Two 2" studs as
fireblocking
R302.2
TWO-FAMILY DWELLING SEPARATION
1-hour
separation
whether or
not a lot line
exists
between
units
R302.3
Mechanical Ventilation
Whole-house mechanical
ventilation system or a
mechanical ventilation
system capable of producing
0.35 ACH in habitable rooms
Local exhaust system is an
acceptable substitute for
natural ventilation in
kitchens
R303.1
Glazing and Wet Surfaces
Replaced the word
“facing” with the
words “adjacent to”
for those elements
related to wet
surfaces.
R308.4.5
Window Fall Protection
• Measurements for determining
need for fall protection taken to
bottom of clear opening of window
R312.2
Smoke Alarm Locations
• New location requirement addresses high ceilings adjacent to
hallways serving bedrooms
R314.3
Smoke Alarm Locations (Cont’d)
R314.3
Smoke alarms identified as
having resistance to common
nuisance alarms from
cooking sources permitted as
close as 6’ from cooking
appliance
Carbon Monoxide Alarms
• Repairs to existing fuel-fired mechanical systems now trigger retroactive
requirements for carbon monoxide alarms
R315.2.2
Storm Shelters
• Engineered design required
R323.1.1
Photovoltaic Systems
Building-integrated
photovoltaic (BIPV)
systems meeting specified
criteria do not require
firefighter access
pathways and setbacks
R324.6
Habitable Attics
Habitable space above 2nd story or 1st story meets
definition of story – no additional requirements
R326
Habitable Attics
Habitable attic
above 3rd story not
a story if:
• Sprinkler system
• Area limited to
one-half area of
story below
R326
Vapor Retarder
Thicker vapor
retarders now
required
below slabs on
grade
Minimum 10
mil (0.01”)
thick
R506.2.3
Cripple Walls – Fully Sheathed
Applies only to exterior cripple walls
R602.9
Garage Door Labelling
Garage doors shall be labeled with
permanent label provided by
manufacturer
Label shall identify
-manufacturer
-model/series number
-positive and negative design wind
pressure rating
-installation instruction drawing
reference number
-applicable test standard R314.3
Soffits
Requirements for soffit
material and installation
expanded in a new
section
R704
Soffits
R704.1 General wind limitations
R704.2 Soffit installation where
design wind pressure < 30 psf
R704.2.1 Vinyl soffit panels
R704.2.2 Fiber-cement soffit panels
R704.2.3 Hardboard soffit panels
R704.2.4 Wood structural panel soffit
R704.3 Soffit installation where
design wind pressure > 30 psf
R704.3.1 Vinyl soffit panels
R704.3.2 Fiber-cement soffit panels
R704.3.3 Hardboard soffit panels
R704.3.4 Wood structural panel soffit
R704
Metal Roof Shingle Wind Resistance
Requirements for metal
shingle wind resistance
added
R905.4.4.1
High-Efficacy Light Sources
• Definition revision
• Lamps ≥ 65 lumens/W
• Luminaires ≥ 45 lumens/W
• Reflects current technology
and federal standards
N1101.6
Climate Zones
• Comprehensively updated
• New Climate Zone 0
• Approximately 10% of US
counties assigned new climate zone
N1101.7
Compliance Options
• Options revised
• Prescriptive and mandatory labels in section titles removed
N1101.13
Compliance Options (Cont’d)
• Prescriptive Compliance
• Total Building Performance
• Energy Rating Index
• Tropical Climate Region
N1101.13
Permanent Energy Certificate
• Additional information • Building thermal envelope
• Solar energy
• Energy Rating Index (ERI)
• Code edition
N1101.14
N1102.2.4 Access Hatches and Doors
• Prescriptive provisions for insulation levels and mandatory provisions
for installation (weather stripping and baffles) have been placed in
separate sections.
• Provisions addressing pull-down stairs have been added.
N1102.2.7
Floor Insulation
• Cavity insulation compliance
• Underside of subfloor
• Top side of ceiling
• Continuous insulation top side of ceiling
Building Air Leakage and
Testing
• 5 ACH for all compliance paths
• 3 ACH for prescriptive path in climate zones 3-8
• Heated attached and detached garages field verified
for air barrier and insulation
• Exception to quantify air leakage in attached and
small volume dwelling units
• Changes throughout Air Barrier, Air Sealing, and
Insulation Installation table
Building Air Leakage and Testing
N1102.4 & Table N1102.4.1.1
N1102.4.6
Air-Sealed Electrical Boxes
• Electrical and communication outlet boxes in
thermal envelope
• Sealed
• Tested NEMA OS 4
• Marked "NEMA OS 4" or "OS 4"
• Installed per manufacturer's instructions and
NEMA OS 4
• Where ductwork qualifies as
being in conditioned space
• Duct system completely within
continuous air barrier and thermal
envelope • Duct work in ventilated
attic and buried in ceiling
insulation
• Duct work in floor cavities over
unconditioned space
• Duct work in exterior walls
N1102.4.6
Duct Installation
• Exception for testing ducts in conditioned spaces deleted
N1102.3.5
Duct Testing
Lighting Equipment
• High-efficacy lighting now required in all permanent lighting
fixtures
• New provisions regulate lighting controls for interior and
exterior lighting
N1102.3.5
Through-the-wall Vent Terminals
G2427.8
Makeup Air for Dryer Installed in a Closet
• The requirement for a
transfer opening for
supplying makeup air
to a closet designed for
a gas dryer has been
moved into a separate
section.
Transfer grite
min. 100 sq. in. free area
Commercial Cooking Appliances
• Prohibited
Hot Water Piping Length to Fixtures
Fixture Traps as Cleanouts
• Removable traps and
removeable fixtures
with integral traps
acceptable for use as
cleanouts
Relining of Building Sewers and Building
Drains
• Recognizes various
available technologies
for relining of existing
building sewer and
building drainage piping
• Clarifies inspection
procedures
Emergency Service Disconnects
Required in a readily
accessible outdoor
location
Service Surge-Protective Device
SPD now
required at
service
panel
Bathroom Branch Circuits
• Dedicated 20-amp circuit for required outlets
or those serving a countertop only
Bathroom Branch Circuits
• Receptacle outlets prohibited
within 3’ horizontally from
bathtub rim or shower stall
threshold
Garage Branch Circuits
Dedicated 20-amp circuits for required outlets only